FarmTek 115236 User manual

Galvanized Box Fans—Belt Drive
Instruction Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the equipment described within this manual. Carefully follow all safety information.
Save this manual for future reference.
Model # _______________________________
Purchase Date: _________________________
Date: 04/27/18
Form: HV0021 Version 3
Model Numbers Covered:
115236, 116188, 116193

Specifications
Dimension (In.) Rough-in Opening
Model Prop Dia. A B CDHeight Width Ship Wt Ship. Dims.E
115236 36” 40 1/8 14 18 3/8 40 3/4 40 3/4 110 44x22x47-
116188 48” 52 1/8 17 22 3/8 52 7/8 52 7/8 128 56x26x58-
116193 48” 52 1/8 17 22 3/8 52 7/8 52 7/8 150 56x29x5825
Getting Started
Tools/Materials Needed:
• Drill/drill bits
• 5/16” nut driver
• Construction screws
• Caulk or sealant
Contents:
• Galvanized box fan(1)
• Instruction manual(1)
Inspection:
After unpacking your exhaust fan, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged
parts. If there is physical damage to any parts of the fan, a freight claim must be filed with the carrier. Check to assure that all bolts, screws and set
screws are securely tightened and have not become loose during transit. Retighten as required. Rotate propeller by hand to assure it turns freely.
General Safety Instructions
Danger: Before installing or servicing, always lock out and tag power source. Do not rely on a switch as the only means
of disconnecting power. Failure to disconnect power can result in fire, electrical shock or serious injury. Motor will restart without
warning after thermal protector trips. Do not touch an operating motor as it may be hot enough to cause injury. Do not place any body
parts or objects in fan or drive components while fan is connected to a power source.
Warning:
1. Read and follow all instructions, cautions, dangers and warnings. Failure to do so could result in personal injury, death or property damage.
2. Make sure the electrical power source conforms to the requirement of the fan(s) as well as local codes.
3. Electrical connections, installation and maintenance must be done by qualified electrical personnel in accordance with all applicable codes and
ordinances.
4. Unit must be adequately grounded.
5. To reduce the risk of fire or electrical shock, do not expose this fan to water.
6. Do not touch electrically live components.
7. Free rotation of the propeller is critical. It must not touch any part of the venturi, framework or drive components.
8. Assure that all power cords do not come in contact with any sharp edges, hot surfaces or chemicals. Immediately replace any damaged cords.
Caution: OSHA requires OSHA compliant guards when fan is installed within 7ft of the floor or working level.

Troubleshooting Guide
Symptom Possible Cause(s) Corrective Action
Fan will not start 1. Tripped circuit breaker 1. Reset circuit breaker
2. Defective motor 2. Repair or replace
3. Incorrectly wired 3. Shut off power, check for proper connections
4. Electricity turned off 4. Contact local power company
Excessive noise or vibration 1. Blade is hitting housing 1. Free blade of obstruction
2. Blade is bent 2. Replace blade
3. Fan not securely anchored 3. Secure properly
4. Bad/noisy bearings 4. Replace motor
Insufficient airflow 1. Incorrect voltage applied 1. Wire properly
2. Defective motor 2. Replace motor
3. Propeller is damaged 3. Replace propeller
4. Blocked Airflow 4. Remove obstructions
5. Not enough intake air 5. Add additional air intake openings
6. Fan is dirty 6. Clean fan guards/screens, motor and propeller
Motor overheats or trips out 1. Over/under line voltage 1. Contact local power company
2. Defective motor 2. Replace motor
3. Fan is dirty. 3. Clean fan guards/screens, motor and propeller
4. Not enough intake air 4. Add additional air intake openings
Fan Installation
Caution: Before operating your new fan, check blade for proper torque, check all fasteners for tightness and assure
screens and/or shutters are securely in place.
For framing dimensions, refer to rough-in opening height and width shown in the specifications above.
Position the fan for desired airflow. Air will discharge on the side of the fan facing the propeller.
Assure the fan is fastened securely in the opening to avoid excess “rattling” or vibration using proper fasteners. Fasteners not included.
Refer to motor nameplate for wiring diagram.
Maintenance
Periodic maintenance schedules should be set to assure reliability and performance of the fan. This maintenance should included inspection
of all fasteners, propeller torque and proper cleaning of the complete fan assembly.
Check for excessive vibration while fan is running.
Periodically inspect and tighten all set screws and hardware.
Assure all mounting hardware, chains, etc. are properly secured.
Motors feature permanently sealed ball bearings and require no further lubrication.
The fan propeller should be periodically cleaned to assure proper balance and performance.
Grease pillow block bearings seasonally. Use caution not to apply too much grease as it may damage the seals.
Periodically check for proper belt alignment.
Performance
CFM(115/230v) CFM/Watt(115/230v)
Model HP F.L.A. Volt. Ph Hz Motor
RPM
0.00"
SP
0.05"
SP
0.10"
SP
0.15"
SP
0.00"
SP
0.05"
SP
0.10"
SP
0.15"
SP
Db
0.00"
SP
115236 1/2 4.8/2.4 115/230 160 1725 10,850 9,990 9,020 7,200 18.4 16.5 14.6 11.4 73
116188 19.4/4.5-4.7 115/208-230 160 1725 19,608 18,228 16,773 15,347 21.6 19.5 17.3 15.4 77.9
116193 19.4/4.5-4.7 115/208-230 160 1725 19,210 17,499 16,185 14,825 20.9 18.8 16.5 14.7 78.2

Ref No Description 115236 116188 116193 Qty
1 Intake & Discharge screen 36SCREEN-N 48SCREEN-N 48SCREEN-N 2, 1
2 Motor A370-4CE A750-4CE(ID) A750-4CE(ID) 1
3 Motor mounting plate N/A N/A N/A 1
4(A,B,C,D) Side housing panels N/A N/A N/A 4
5 Large drive pulley AL94 AL94 AL94 1
6 V belt, cogged AX45 AX61 AX61 1
7 Venturi panel N/A N/A N/A 1
8 Horizontal frame piece N/A N/A N/A 1
9 Propeller 9001470 9001489 9001489 1
10 Horizontal frame bracket, small N/A N/A N/A 2
11 Horizontal frame bracket, large N/A N/A N/A 2
12 Motor pulley AK2858 AK3058 AK3058 1
13 Tensioner bracket(optional) N/A N/A N/A 1
14 Belt tensioner(optional) BTI BTI BTI 1
15 Bearing UCP205-16 UCP205-16 UCP205-16 2
16 Fan shaft, 1" FS7.5 FS7.5 FS7.5 1
- Alum Discharge Shutter N/A N/A SA48X-N 1
Repair Parts Illustration
Note: Aluminum discharge shutter not shown.
This manual suits for next models
2
Table of contents
Other FarmTek Fan manuals
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions