EXFO FIP-400B User manual

User Guide
Fiber Inspection Probe and
ConnectorMax2 Mobile (iOS)
FIP-400B

ii FIP-400B
Copyright © 2016–2017 EXFO Inc. All rights reserved. No part of this
publication may be reproduced, stored in a retrieval system or transmitted
in any form, be it electronically, mechanically, or by any other means such
as photocopying, recording or otherwise, without the prior written
permission of EXFO Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
Trademarks
EXFO’s trademarks have been identified as such. However, the presence
or absence of such identification does not affect the legal status of any
trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and
practices.
Patents
Feature(s) of this product is/are protected by one or more of: US design
patent D751434 and equivalents in other countries.
Version number: 15.0.1.1

Contents
Fiber Inspection Probe iii
Contents
Certification Information ........................................................................................................v
1 Introducing the FIP-400B Fiber Inspection Probe and
ConnectorMax2 Mobile ................................................................................ 1
Probe ......................................................................................................................................2
Available Models ....................................................................................................................5
Probe Tips ...............................................................................................................................6
LED Indicators .........................................................................................................................6
ConnectorMax2 Mobile Software ..........................................................................................9
Technical Specifications .........................................................................................................10
Conventions ..........................................................................................................................11
2 Safety Information ..................................................................................... 13
Other Safety Symbols on Your Unit .......................................................................................15
Electrical Safety Information .................................................................................................16
3 Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile ..... 19
Preparing to Use the Mobile Application ..............................................................................19
Connecting or Disconnecting the Wireless Probe ..................................................................20
Changing the Fiber Inspection Probe Tip ..............................................................................23
Changing the FIP Nozzle (MF-Ready Probes Only) .................................................................24
Adjusting Brightness .............................................................................................................30
Setting up Identification .......................................................................................................32
Setting up the Incrementation ..............................................................................................34
Setting up Autonaming ........................................................................................................37
Setting up Auto Capture .......................................................................................................40
Managing and Selecting Test Configurations ........................................................................42
Modifying the File Format .....................................................................................................53
Stopping the Analysis Process on First Fail ............................................................................55
Restoring to Default Settings ................................................................................................57

Contents
iv FIP-400B
4 Inspecting Fiber Ends .................................................................................59
Inspecting Fiber Ends (Single Fiber and Transceiver - Fiber Receptacles) ..............................59
Inspecting Multiple Fiber Ends (MF-Ready Probes Only) .......................................................65
Saving Files ...........................................................................................................................75
Managing Files ....................................................................................................................78
Analyzing Captures ...............................................................................................................83
Creating and Viewing Reports ..............................................................................................89
Transferring Results With Third-Party Applications ................................................................93
Transferring Results Directly With Your Smart Device ............................................................99
Updating the Firmware .......................................................................................................100
5 Maintenance ..............................................................................................101
General Maintenance ..........................................................................................................101
Cleaning Lenses ..................................................................................................................102
Recycling and Disposal .......................................................................................................102
Recharging the Battery (FIP-425B and FIP-435 Models Only) ..............................................103
Replacing the Battery (FIP-425B and FIP-435 Models Only) .................................................104
6 Troubleshooting ........................................................................................107
Solving Common Problems .................................................................................................107
Changing the File Contents ................................................................................................110
Contacting the Technical Support Group ............................................................................112
Viewing Information About ConnectorMax2 Mobile .........................................................113
Viewing Online Help ...........................................................................................................114
Transportation ....................................................................................................................115
7 Warranty ....................................................................................................117
General Information ...........................................................................................................117
Liability ...............................................................................................................................118
Exclusions ...........................................................................................................................118
Certification ........................................................................................................................118
Service and Repairs .............................................................................................................119
EXFO Service Centers Worldwide ........................................................................................120
A Fiber Inspection Probe Tip Compatibility Chart .....................................121
Index ...............................................................................................................125

Certification Information
Fiber Inspection Probe v
Certification Information
North America Regulatory Statement
This unit was certified by an agency approved in both Canada and the
United States of America. It has been evaluated according to applicable
North American approved standards for product safety for use in Canada
and the United States.
Electronic test and measurement equipment is exempt from FCC part 15,
subpart B compliance in the United States of America and from ICES-003
compliance in Canada. However, EXFO Inc. makes reasonable efforts to
ensure compliance to the applicable standards.
The limits set by these standards are designed to provide reasonable
protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the user guide, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Modifications not expressly approved by the manufacturer could void the
user's authority to operate the equipment.

Certification Information
vi FIP-400B
The wireless probe comes with an internal wireless module and antenna
for which the following information applies:
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules.
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may
cause undesired operation.
This device complies with the US/Canada portable RF exposure limit
set forth for an uncontrolled environment and is safe for intended
operation as described in this user documentation. The further RF
exposure reduction can be achieved if the device can be kept as far as
possible from the user’s body.
This device does not contain any user-serviceable components. Any
unauthorized product changes or modifications will invalidate
warranty and all applicable regulatory certifications and approvals.

Certification Information
Fiber Inspection Probe vii
European Community Declaration of Conformity
Warning: This is a class A product. In a domestic environment, this product
may cause radio interference in which case the user may be required to
take adequate measures.
Hereby, EXFO declares that the radio equipment type “Wideband Data
Transmission” is in compliance with European Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following
Internet address: www.exfo.com/library.
The information about the Wi-Fi frequency bands is as follows:
Between the frequencies 2400.0 MHz - 2483.5 MHz.
The maximum output power is 15 dBm.
This device is a 2.4 GHz wideband transmission system (transceiver),
intended for use in all EU member states and EFTA countries, except in
France and Italy where restrictive use applies.
In Italy, the end-user should apply for a license at the national spectrum
authorities in order to obtain authorization to use the device for setting up
outdoor radio links and/or for supplying access to telecommunications
and/or network services.
This device may not be used for setting up radio links in France, and in
some areas the RF output power may be limited to 10 mW EIRP in the
frequency range of 2454 - 2483.5 MHz. For detailed information, the
end-user should contact the national spectrum authority in France.

Certification Information
viii FIP-400B
Japanese Technical Conformity Mark for Radio
Law
Technical parameters:
Standards: IEEE 802.11b/g/n
Operation Frequency: 2412 ~ 2483.5 MHz
Throughput: 150 Mbps, 1T1R
R018-160052

Fiber Inspection Probe 1
1 Introducing the FIP-400B Fiber
Inspection Probe and
ConnectorMax2 Mobile
The FIP-400B Fiber Inspection Probe is a portable video microscope used
to inspect fiber ends. Unlike traditional microscopes, the FIP-400B
facilitates the examination of patchcord connectors and also hard-to-reach
connectors on the back of patch panels and bulkhead adapters.
There are two different types of probes:
USB-wired probes, that are connected to platforms
wireless probes, that can be connected with a Wi-Fi or USB connection
to platforms or with a Wi-Fi connection to a mobile smart device
(Android or iOS)
standard wireless probes can inspect single fibers and transceivers
MF-Ready probes can inspect single fibers, transceivers and
multifiber connectors (mobile smart devices only)
Note: The appearance and the orientation (portrait or landscape) of the
application may vary depending on the smart device used.

Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
2FIP-400B
Probe
Probe
The FIP-400B is designed to be an intuitive, easy-to-use piece of
equipment. This video microscope is used for inspecting fiber ends.
Status LED
Retaining nut
Focus
Magnification control
Capture control
Interchangeable adapter
tips
Micro USB adapter connector
Battery compartment door
Battery LED
Wi-Fi LED
Other manuals for FIP-400B
3
Table of contents
Other EXFO Test Equipment manuals

EXFO
EXFO IQS-8500 Series User manual

EXFO
EXFO LETP-700 Series User manual

EXFO
EXFO RTU-310 User manual

EXFO
EXFO FOT-930 MaxTester User manual

EXFO
EXFO MAX-700 User manual

EXFO
EXFO FVA-3100 User manual

EXFO
EXFO bv10 User manual

EXFO
EXFO FTB-700 Series User manual

EXFO
EXFO FTV-700 series User manual

EXFO
EXFO FTB-85100G User manual

EXFO
EXFO FOT-920 MaxTester User manual

EXFO
EXFO MaxTester Max-610 User manual

EXFO
EXFO Power Blazer User manual

EXFO
EXFO IQS-12001B User manual

EXFO
EXFO OTH-7000 User manual

EXFO
EXFO FVA-600 User manual

EXFO
EXFO MaxTester 635 User manual

EXFO
EXFO EPM-500 User manual

EXFO
EXFO FTB-3930 User manual

EXFO
EXFO FTB-800 Series User manual





















