EXFO TG-300B User manual

ii
Copyright © 2006–2009 EXFO Electro-Optical Engineering Inc. All rights reserved. No
part of this publication may be reproduced, stored in a retrieval system or
transmitted in any form, be it electronically, mechanically, or by any other means
such as photocopying, recording or otherwise, without the prior written permission
of EXFO Electro-Optical Engineering Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable. However, no
responsibility is assumed by EXFO for its use nor for any infringements of patents or
other rights of third parties that may result from its use. No license is granted by
implication or otherwise under any patent rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North Atlantic
Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without notice.
Trademarks
EXFO’s trademarks have been identified as such. However, the presence or
absence of such identification does not affect the legal status of any trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and practices.
Patents
TG-300B/LFD-300B FiberFinder technology and applications protected by PCT
published patent appl. WO/2006/092051, US patent number 7,283,688, and
associated national entries in several countries.
Version number: 2.0.0
WWW.FIBEROPTICBANK.COM

TG-300B/LFD-300B FiberFinder iii
Contents
Certification Information ................................................................................. iv
1 Introducing the TG-300B/LFD-300B FiberFinder ...................... 1
General Description .......................................................................................... 1
Power Sources .................................................................................................. 4
Typical Applications .......................................................................................... 4
Conventions ...................................................................................................... 4
2 Operating the TG-300B/LFD-300B FiberFinder ......................... 5
Installing the Fiber in the Alignment Groove .................................................... 6
Identifying Live Fibers ....................................................................................... 7
Identifying Dark Fibers ...................................................................................... 8
Determining if a Fiber Is Live or Dark ................................................................ 9
Using the Optional Flexible Arm ..................................................................... 10
3 Maintenance ............................................................................ 11
Replacing the Four AA Batteries ...................................................................... 11
Recycling and Disposal (Applies to European Union Only) .............................. 12
4 Troubleshooting ...................................................................... 13
Display Code Description ................................................................................ 13
Operation in Cold Temperatures ..................................................................... 14
Contacting the Technical Support Group ........................................................ 14
Transportation ................................................................................................ 15
5 Warranty .................................................................................. 17
General Information ....................................................................................... 17
Liability ........................................................................................................... 17
Exclusions ....................................................................................................... 18
Certification .................................................................................................... 18
Service and Repairs ......................................................................................... 19
EXFO Service Centers Worldwide .................................................................... 20
A Technical Specifications .......................................................... 21
WWW.FIBEROPTICBANK.COM

Certification Information iv
Certification Information
F.C.C. Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in the United
States. However, compliance verification tests are systematically performed on
most EXFO equipment.
Information
Electronic test equipment is subject to the EMC Directive in the European Union.
The EN61326 standard prescribes both emission and immunity requirements for
laboratory, measurement, and control equipment. This unit has undergone
extensive testing according to the European Union Directive and Standards.
WWW.FIBEROPTICBANK.COM

TG-300B/LFD-300B FiberFinder v
Application of Council Directive(s): 2006/95/EC - The Low Voltage Directive
2004/108/EC - The EMC Directive
And their amendments
Manufacturer’s Name: EXFO Electro-Optical Engineering Inc.
Manufacturer’s Address: 400 Godin Avenue
Quebec, Quebec
Canada, G1M 2K2
(418) 683-0211
Equipment Type/Environment: Test & Measurement / Industrial
Trade Name/Model No.: LFD-300B/TG-300B FiberFinder
LFD-250B Live Fiber Detector
Standard(s) to which Conformity is Declared:
EN 61010-1:2001 Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use, Part 1: General Requirements.
EN 61326-1:2006 Electrical Equipment for Measurement, Control and Laboratory
Use - EMC Requirements – Part 1: General requirements
EN 55022: 1998 +A2: 2003 Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standards.
Manufacturer
Signature:
Full Name: Stephen Bull, E. Eng
Position: Vice-President Research and
Development
Address: 400 Godin Avenue, Quebec (Quebec),
Canada, G1M 2K2
Date: July 10, 2009
DECLARATION OF CONFORMITY
WWW.FIBEROPTICBANK.COM

Introducing the TG-300B/LFD-300B FiberFinder 1
1 Introducing the
TG-300B/LFD-300B
FiberFinder
The FiberFinder detects traffic and measures optical signals transmitted through
singlemode fibers without having to disconnect them.
It uses a proven macrobending technique, with an insertion loss of less than 1 dB,
that does not disrupt traffic allowing you to safely work on live fibers.
General Description
The status of all functions are indicated by LEDs located on the front panel of the
unit.
Tone recognition
TG-300B
Fiber Modulator
LFD-300B
Positioning
ON/OFF
and
battery status
Traffic
direction
Fiber Finder
WWW.FIBEROPTICBANK.COM

TG-300B/LFD-300B FiberFinder 2
³Tone recognition LEDs: Indicate if a tone of 270 Hz, 1 kHz, or 2 kHz was
recognized by the LFD300B.
³Traffic LEDs: Indicate the presence and direction of the traffic as follows:
³When the Traffic LED on the left-hand side is lit, the traffic is coming from
the right.
³When the Traffic LED on the right-hand side is lit, the traffic is coming from
the left.
³Fiber Finder LED: Indicates if the low-frequency modulation (specific to the
TG300B) was detected by the LFD300B.
³Fiber Modulator LED: Indicates if the low-frequency modulation was emitted by
the TG300B.
³Positioning LED: Blinks while the clamping mechanism presses on the fiber.
³ON/OFF and battery status LED: Is constantly lit while the unit is running and
blinking when the batteries are low.
WWW.FIBEROPTICBANK.COM

Introducing the TG-300B/LFD-300B FiberFinder 3
The switch and the display are located on the front of the unit. The battery
compartment is located on the back panel and the connection for the AC adapter is
at the bottom.
IMPORTANT
When you are not using your unit, put the switch in the upward
position to avoid premature wear of the clamping mechanism.
Switch: Clamps the fiber
under test in place and
turns on the unit.
Display
Alignment groove: for the fiber
under test
Head of the unit
Protective cap: Reduces the influence that
ambient light might have on test results.
Battery
compartment Back panel
AC adapter
connector
WWW.FIBEROPTICBANK.COM

TG-300B/LFD-300B FiberFinder 4
Power Sources
The unit operates with the following power sources:
³AC adapter (connected to standard power outlet—indoor use only)
³Four alkaline AA batteries or rechargeable batteries.
Typical Applications
You can use your FiberFinder to:
³Locate a live fiber.
³Locate a dark fiber.
³Determine if a fiber is live or dark.
³Identify traffic direction on a live fiber.
Conventions
Before using the product described in this manual, you should understand the
following conventions:
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in component damage. Do not proceed unless you
understand and meet the required conditions.
IMPORTANT
Refers to information about this product you should not overlook.
WWW.FIBEROPTICBANK.COM

Operating the TG-300B/LFD-300B FiberFinder 5
2 Operating the
TG-300B/LFD-300B
FiberFinder
You can identify live or dark fibers using the TG-300B as the transmitter and the
LFD-300B as the receiver. You can also determine if a fiber is live or dark using the
LFD300B.
CAUTION
Do not use your units with fibers of which diameters are smaller
than 900 μm as the pressure could damage them.
IMPORTANT
Depending on the fiber type, the color, and the rubber jacket
stiffness, the test results may be very different from the ones
presented in this guide.
WWW.FIBEROPTICBANK.COM
This manual suits for next models
1
Table of contents
Other EXFO Recording Equipment manuals