If you set a different address, each unit will start to ' listen' to the channel number you have set,
based on the quantity of control channels of the unit. That means changing the settings of one
channel will affect only the selected fixture.
In the case of the scanner, which is a 8 channel fixture, you should set the starting address of the first
unit to 1, the second unit to 9 (8 + 1), the third to 17 (9 + 8), and so on.
Note:
After switching on, the machine will automatically detect whether DMX 512 data is received or not. If the data is
received, the display will show "A.001" with the actual set address. If there is no data received at the DMX-input,
the display flashes "A 001" with the actual set address & the unit automatically goes into Sound to Light mode.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the machine.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap in the
input connector.
Control Board
The Control Board offers several features: you can simply set the starting address, switch on and off the lamp, run
the pre-programmed program or make a reset.
The main menu is accessed by pressing the Enter-button for 3 seconds until the display starts flashing. Browse
through the menu by pressing the Up-button. Press the Enter-button in order to select the desired menu. You can
change the selection by pressing the Up-button. Confirm every selection by pressing the Enter-button. You can
leave every mode by pressing the Exit-button. The functions provided are described in the following sections.
Default settings shaded.
Main
menu Sub menu Extension Display Function
VA L U A001~A511 (AXXX) DMX address setting
ADDR SLAV ON/OFF (SLAV) Slave setting
ALON (AU-A) Automatic Program Run
in Stand Alone
AUTO
MAST (AU-M) Automatic Program Run
as Master
ALON (SO-A) Sound-controlled Program
Run in Stand Alone
RUN
SOUN
MAST (SO-M) Sound-controlled Program
Run as Master
VA L U D-00 ~ D-30
(DXXX)
Display the DMX 512 value
of each channel
RDIS ON/OFF Reverse display
0 M ODE
DISP
CLDI ON/OFF Shut off LED display
RPAN ON/OFF Pan Reverse
RTI L ON/OFF Tilt Reverse
REST ON/OFF Reset
LODA ON/OFF Restore factory settings
OLVE ON/OFF Software version change
1 SE T
VER V-1.0~V-9.9 Software version
LADJ ON/OFF Lamp adjustment
2 ADJ U TEST T-0 1 ~ T- 30 Test function of each channel
MATI 0000~9999 (hours) Fixture running time
LATI 0000~9999 (hours) Lamp running time
3 T I M E
CLMT ON/OFF Clear fixture time
8