This manual is intended to guide ETC Service Technicians through the process of
upgrading existing Sensor®touring racks to Sensor+ touring racks with an CEM+ control
module. This manual covers SP24 and SP48 touring racks.
If you have questions about the retrofit process that are not answered in this manual, please
contact ETC Technical Services.
Please email comments about this manual to: TechComm@etcconnect.com
Warnings and Notice Conventions
These symbols are used in Sensor documentation to alert you to danger or important
information:
Americas
ETC International
Technical Services Department
3031 Pleasant View Road
Middleton, WI 53562
+1 800 775 4382
+1 608 831 4116
Note:
Notes are helpful hints and information that is supplemental to the main text.
CAUTION:
A Caution statement indicates situations where there may be undefined or
unwanted consequences of an action, potential for data loss or an equipment
problem.
WARNING:
A Warning statement indicates situations where damage may occur, people
may be harmed, or there are serious or dangerous consequences of an
action.
WARNING:
RISK OF ELECTRIC SHOCK! This warning statement indicates situations
where there is a risk of electric shock.

2CEM+ Sensor Rack Retrofit Manual
Safety
Please note the following safety warnings before use:
• Disconnect power from the rack(s) before all maintenance.
Overview of this Manual
Reference this manual throughout the retrofit procedure.
•Preparation, page 5 - before you open the rack.
•Remove the Old, page 5 - labeling and remove the existing equipment.
•Control Input Panel Replacement, page 6 - remove the existing control input panel from
the rear of the rack and install the new one.
•Power Termination, page 8 - install and secure the power harness adapter cable.
•Data Cabling Preparation, page 8 - install and secure the dimmer data transition
boards.
•Install the New Backplane & Make Connections, page 9 - install the new backplane and
connect and secure the data cabling.
•Change out the AF Cards (if present)), page 11 - remove the existing Advanced
Feature cards and install the new ones.
•Finish Up, page 11 - reinstall the left side of the rack.
•Verify the Retrofit, page 12 - put the dimmers back in the rack and power up the rack.
•Configure the CEM+, page 12 - put a configuration in the CEM+.
When viewing this document in electronic form (pdf file) with Adobe Acrobat Reader, blue
italicized text followed by a page number such as “Overview of this Manual, page 2” is a
link within the document. If you click on the link, it will jump to that section or topic.
WARNING:
RISK OF ELECTRIC SHOCK! Dimmer racks without an accessible power
disconnect device cannot be serviced safely.

1Unpack and Organize 3
Section 1
Unpack and Organize
The table below lists the parts and components needed to retrofit a Sensor rack up to a
Sensor+ rack with a CEM+. Each part is listed to reflect the different quantities for the
different kits and types of racks.
Parts/Components
ETC Part Number
SP48 & SP96
7153K1001
Parts Included in the Kits
Shipped Assembled
CEM+ Backplane Bracket
7150A3002 1
CEM+ Backplane 120V Port PCB Assy
7150B5203 1
CEM+ Backplane Label
7150A4005 1
Stand-off (4-40x.375 M-F 3/16-HX AL)
HW9322 6
CEM+ Backplane Short Shield
7150A3007 1
Screw (4-40X1/4 SEMS PhPHMS)
HW183 8
Shipped Assembled
CEM+ DMX & Beacon PCB Assembly
7150B5010 1
SP48/96 Tour Rack Control Panel
7153A3001 1
Panel Mount Cat5 F to F Jack (XLR case)
N2030 1
Hole Plug .375 dia 2617 Heyco
HW624 1
SCR M3x.5x4mm PhOHMS BZ
HWM1036 8
Shipped as Individual Parts
Backplane Screw (8-32X3/8 PhPHMS)
HW377 2
CEM+ Backplane 1/8” #8 screw spacer
HW9343 2
Wire tie - 4”
HW701 14
Tie-mount (sticky-back)
HW741 4
Ribbon cable clamp (sticky-back)
HW746 8
CAT5 Cable RJ45/RJ45 UTP 2FT
N4035 1
SP48/96+ Tour rack door baffle
7153A3002 1
SP48/96+ Backplane to DMX PCB data ribbon cable
7153B8001 1
CEM+ UPGRADE 16-PIN Power Cable
7150B7002 1
PCB Upgrade 16-Pin Power
7150B4009A 1
CEM+ Lower Ribbon Card Assy
7150B5006 2
CEM+ Upper Ribbon Card Assy
7150B5007 2
CEM+ Sensor Touring Rack Retrofit Manual (this manual)
7153M2300 1
Bag 12x18 3mil stat/shld flat
I1017 1
Bag 3x5 3mil Anti/stat zipper
I1019 2
Bag 6x9 2mil economy zipper
I169 1
Bag 2x3 2mil economy mini grip zipper
I195 1
Bag 4x8 2mil zipper
I199 1
Box/Rack 15-7/16 x 3-7/8 x 25-3/16
I146-3 1

4CEM+ Sensor Rack Retrofit Manual
Parts/Components
ETC Part Number SP24 SP48
Additional
Line Items
Sensor+ AF Cards (Optional)
7150B5005 24
CEM+
7150A1001 11
Required Tools
#1 Phillips screwdriver
#2 Phillips screwdriver
Diagonal wire cutter
5/16” nut driver
Permanent marker

2The Retrofit 5
Section 2
The Retrofit
Preparation
Step 1: Use Sensor Configuration Editor and a SLTA to download and save the current
Sensor configuration out of racks for later reference.
Step 2: Turn off the main breaker and disconnect all of the Cam-Lok® connectors from
the touring rack.
Step 3: Pull the modules out of the rack. Note and document the module’s
order/positioning in the rack for proper insertion and configuration later.
Step 4: Use a digital voltmeter and VERIFY that power is off by checking voltages for all
combinations between the phase bars, neutral and ground.
Step 5: Remove the rack door in front of the CEM
by pushing down on the tab in top hinged
corner.
Step 6: Remove the left side of the touring rack
(10 Phillips head screws) and set it aside.
Remove the Old
Step 1: Unscrew the dimmer output edge connectors from the backplane metal.
Step 2: Carefully feed the dimmer output ribbon cables through the backplane
individually. As you remove the ribbon cables, mark them with a permanent
marker them as illustrated above in the hexagons. There may be stickers on the
ribbon cables already, however these refer to cable length and not dimmer
outputs. They should not be used as a reference to these instructions.
Step 3: Examine each ribbon cable for any nicks or cuts due to backplane scrapes.
Step 4: Unscrew and remove the control data cable connector (J3) from the backplane
and feed it through the metal work.
Step 5: Unscrew the power edge connector (J1). Remove it from the backplane by
sliding it out of the notch in the rack and carefully pushing it through the
Note:
The order/layout of the dimmer output edge connectors is different on the CEM+
backplane.
Remove
1-Push
2
-
R
e
m
o
v
e
CEM SP48 Ribbon Cable Layout
(1-24)
(73-96)
(49-72)
(25-48)
1
3 4
2
(25-48)
(1-24)
CEM SP24 Ribbon Cable Layout
1 2
J1
J3
J1
J3

6CEM+ Sensor Rack Retrofit Manual
backplane metal. This connector will be used in the upgrade.
Step 6: Unscrew the backplane metal from the rack. (One screw in each side upper-
corner - two screws total.) Discard these screws. Replacement screws with
thread locker are provided (ETC Part# HW377).
Step 7: Push the backplane towards the back of the rack to free the backplane side tabs
Step 8: Bend the sides into the center (out of the sides of the rack).
Step 9: Slide backplane metal forward in order to
allow easier working space while
removing data terminations.
Step 10: Finish removing the old backplane
metalwork. Discard the old backplane.
Control Input Panel Replacement
Step 1: From the open left side of the rack,
remove the control data ribbon cable from
the clips inside the rack.
Step 2: Remove the tour guides on the rear of the
rack by loosening (not removing) the
three screws behind each tour guide.
Once the screws are loose, slide the tour
guide toward the center of the rack to
remove it.
Step 3: Remove the two screws that hold in the
breaker on the left side of the control
panel.
Step 4: Remove the screw on each side of the old control input panel.
Step 5: Pull the control input panel out a couple inches.
a: Unplug the beacon connector (twisted red & black wire).
b: Completely pull the panel out of the rack.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
6
8 8
9
7
Remove the
backplane screws
R
e
mo
v
e
Re
m
o
v
e
D
i
s
c
a
r
d

2The Retrofit 7
Step 6: Connect the data cables
to the new control input
panel.
a: Insert the Ethernet
cable in the RJ45 jack
on the rear of the
control input panel.
b: Connect the new
control data ribbon
cable connector (the
connector is keyed - the
ribbon cable will go up)
in the new control input
panel ribbon cable
header. Both ends of
the control data
ribbon cable are the
same.
c: Connect the beacon
connector to either the
first or last pair of the
beacon header (show
here).
Step 7: Feed the cables into the rack where the control input panel will go and reinstall
the breaker with the same two screws. Be sure to note the proper on/off
orientation of the breaker to the panel labeling (The new panel and the old
panel are the same).
Step 8: Install the new control input panel in the rack. Leave the screw on each end of
the panel a bit loose for the next step.
Step 9: Reinstall the tour guides (under the screw heads still in the rack) and fully tighten
the screws for each side.
Co
n
n
e
c
t
C
o
nn
ec
t
C
o
n
n
e
c
t
Use either pair

8CEM+ Sensor Rack Retrofit Manual
Power Termination
Step 1: Clip the first wire-tie behind the existing J1 power connector to give the harness
more room to move while you work.
Step 2: Install the power adapter harness to edge connector (straight thru PCB) to old
power connector (match the wire colors)
.
Step 3: Secure the power connectors together with provided 4"-wire-ties. Clip wire tie
ends for neatness.
Step 4: In line with where the backplane will go and all the way back of that sheet metal,
mount a sticky-back tie wrap mount.
Step 5: Use that tie wrap mount to loosely secure the power harness to the side of the
rack. Leave the tie wrap loose enough for the power harness to slide backwards
when the backplane is installed.
Data Cabling Preparation
Step 1: Identify the different dimmer output ribbon cable transition cards. An SP24 will
only use a single upper and lower card.
Note:
There are two different types. An “upper” card and a “lower” card. The transition
card is marked for both the type and which side is up when installed.
Oh,IwishIwereanOscarMeyer®wiener...
Wire-tie the
connectors
together
The PCB is the same on
both sides, top and bottom.
Match the
wire colors
1
3
4
2
This is an “Upper”
transition board
(7150B5007)
This is an “Lower”
transition board
(7150B5006)
Other manuals for sensor+ CEM+
2
Table of contents
Other ETC Rack & Stand manuals

ETC
ETC ESR3 Series User manual

ETC
ETC CLARETTE GANGING User manual

ETC
ETC EOS User manual

ETC
ETC Emphasis 4200A2009 User manual

ETC
ETC P-TS18-RM User manual

ETC
ETC Sensor+ SR Series User manual

ETC
ETC LIZANNE SINGLE User manual

ETC
ETC Unison Paradigm P-TS7 User manual

ETC
ETC OneTrack by ETC Technical manual

ETC
ETC Sensor 3 User manual
Popular Rack & Stand manuals by other brands

Salamander
Salamander Acadia AC/W/L400/WH Assembly instructions

Fohhn
Fohhn VAT-09 Mounting instruction

ricoo
ricoo FS0522 quick start guide

AMSOIL
AMSOIL BMK-22 Installation and service instructions

Kargo Master
Kargo Master 48220 installation guide

Milestone AV Technologies
Milestone AV Technologies SIMPLICITY SLF2 installation instructions