CAUTION! When replacing batteries, replace with the same number of the sealed lead-acid batteries.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains
no user replaceable parts. Only authorized service personnel may perform repairs.
CAUTION! Do not stick fingers into sockets.
Please follow the instructions to correctly position your UPS:
1. The UPS must be placed on a horizontal surface.
2. This UPS is projected for indoor use.
3. The UPS must not be exposed to direct sunlight or any heat source.
4. The air temperature must be between 0°C and 40° C (25°C is the ideal temperature).
5. Ambient humidity must be less than 90%.
6. The UPS must not be placed on dusty environments.
7. The UPS must be placed at least 15 cm. far from walls to ensure enough ventilation.
8. Do not obstruct or pour any liquid on ventilation holes.
9. Do not cover the UPS with any object.
10. Keep away liquids, flammable gases or corrosive substances.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following: UPS Unit x1, USB cable x1.
HARDWARE INSTALLATION GUIDE
1. The UPS may be used immediately upon receipt. However, recharging battery for at least 8 hours is recommended
to ensure that the battery's max charge capacity is achieved. Charge loss may occur during shipping or storage. To
recharge the battery, simply leave the unit plugged into an AC outlet: it will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage
device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser printer,
copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets.
The power demands of these devices will overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected
by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner,
refrigerator, copier, etc). Avoid using extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the
UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make
sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery
every three months to ensure battery life.
600/800 VA
1. Power Switch
Press the switch to turn the UPS ON or OFF.
2. Led Indicators
Three LED indicators include Using AC, Using Battery, and Fault. Refer to “Definitions for Illuminated LED Indicators”
section for details.
3. AC Outlet
The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power
failure and against surges and spikes.
4.Input Circuit Breaker
The Circuit Breaker provides overload protection.
5. RJ45/11 Communication Protection Ports
Provide surge protection for any standard modem, fax, telephone line, or network cable
6. USB COMM. Port
This port allows connection to the USB port on the computer, so to get access to remote monitoring and shutdown
operations through the UPS management software
7. Input Power Cord
Connect to utility power.
INSTALLING YOUR UPS SYSTEM