EPS EGV1.1 User manual

EGV1.1
Self-Monitoring Blood Glucose System
User’s Manual
Dear EGV1.1 SMBG System Owner,
Please read this User’s Manual thoroughly
Before using your blood glucose meter

Thank you for using the EGV1.1 Self-Monitoring Blood Glucose (SMBG) System. We designed this system to
be dependable, easy-to-use, compact, lightweight and portable to help you monitor your blood glucose on a
regular basis.
Please read this manual thoroughly before you begin testing. This manual provides you and your diabetes
care team with important information and step-by-step direction to use the EGV1.1 Self-Monitoring Blood
Glucose System. To start testing quickly, you can also refer to the Quick Reference Guide.
Thanks again for choosing the EGV1.1 SMBG.
Intended Use
The EGV1.1 Self Monitoring Blood Glucose System is intended for the quantitative measurement of
glucose in fresh capillary whole blood samples drawn from the fingertip, palm, or forearm. Testing is done
outside the body (In Vitro diagnostic use). It is indicated for use at home (over the counter [OTC]) by a single
patient with diabetes and should not be shared, as an aid to monitor the effectiveness of diabetes control. The
system is not to be used on neonates, nor for the diagnosis of, or screening for diabetes mellitus. Alternative
site testing can be only used during steady-state blood glucose conditions.

Important Safety Instructions
Lancing devices and meters are for single patient use only. A new, sterile lancet should be used each time
you perform a test. The lancing device, lancets and meter are NOT to be shared between users or other family
members. Do NOT use on multiple individuals. Sharing a lancing device and lancets may transmit blood
borne pathogens, such as viral hepatitis.
All parts of the kit are considered biohazardous and may transmit infection, even if you have performed
cleaning and disinfection. Wash hands thoroughly with soap and water after handling the meter or lancing
device.
For further information, please see: "FDA Public Health Notification: Use of Fingerstick Devices on More
than One Person Poses Risk for Transmitting Bloodborne Pathogens: Initial Communication" (2010)
http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm224025.
"CDC Clinical Reminder: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting
Blood borne Pathogens" (2010) http://www.cdc.gov/injectionsafety/Fingerstick-DevicesBGM.html

Standard Accessories
The EGV1.1 Blood Glucose meter and accessories are working together to measure the amount of glucose
in your blood. The system includes:
Optional Accessories
• EGV1.1 Blood Glucose Meter
• Alkaline Battery (2 ct)
• EGV1.1 Blood Glucose Test Strips (10 pcs)
• Test Strip Instructions
• Lancets (10 pcs)
• Lancing device
• AST Lancing Device Cap
• User’s Manual
• Quick Reference Guide
• Self-Test Log Book
• EGV1.1 Level 2 Control Solution
• Control Solution Instructions
• Carrying Case
• EGV1.1 Level 3 Control Solution
Note:
1. EGV1.1 Level 2 Control Solution is included with the system.
2. EGV1.1 Level 3 Control Solution are available. For purchase, please call the Customer Care
Service toll-free at 866-994-3345 (Eastern Standard Time, Mon-Fri 8:00AM~6:00PM).

Why is it so important to test blood glucose regularly?
Testing your blood glucose regularly can make a big difference in how you manage your diabetes every day.
We have made this SMBG system as simple as possible to help you use it regularly. Your meter is easy to
use, and you can adjust the lancing device for your comfort.
Do you need help?
If you have questions or need assistance, please call the Customer Care Service toll-free at 866-994-3345
(Eastern Standard Time, Mon-Fri 8:00AM~6:00PM). During non-service hours, please contact your healthcare
provider.
Please complete your warranty card and mail it, so you receive the best customer service possible and news
about product update.
Note:
Although the EGV1.1 SMBG System is easy to use, you may need to consult with your
healthcare professional (this may be your doctor, pharmacist or diabetes nurse educator) for
instructions on how to use the system. Only the correct use of the system will ensure
accurate results.

Important Information about Your New Meter
EGV1.1 blood glucose meter is designed and approved for testing fresh capillary whole blood samples
from your fingertip, palm or forearm. The meter is for in vitro diagnostic use ONLY (for testing outside the
body). It should not be used to diagnose or screen for diabetes.
EGV1.1 blood glucose meter can only be used with EGV1.1 Blood Glucose Test Strips. Other test strips
will give inaccurate results.
Testing is not valid for neonatal blood specimens.
Do not disassemble the meter as this may cause damage to the components resulting in incorrect
readings. Disassembling the meter will also void the warranty.
Always keep the meter clean and store it in a safe place. Protect the meter from direct sunlight to ensure
a longer lifespan.
You should not store the meter and test strips in a car, bathroom, or freezer.
Keep the meter, test strips and lancing device away from children and pets.
Critically ill patients should not be tested with this meter.
Incorrect results may occur when performing the test. If you believe you are not feeling well, please
contact your healthcare professional.
Remove batteries if the meter will not be used for one month or more.

Note:
Consult with your healthcare professional before testing on your fingertip, palm or forearm.
Do not touch the strips with wet hands.
Do not use expired strips (the expiration date is shown on the bottle.)
Do not bend, cut or twist the strips.
Altitude up to 10,000 feet above sea level has no effect on readings.
It should not be used to diagnose or screen for diabetes.

Health-Related Information
If you are experiencing dehydration, frequent urination, low blood pressure, shock or hyperosmolar
hyperglycemic nonketotic coma (HHNKC), you may get an inaccurate glucose result. If you think you
have any of these conditions, contact your healthcare provider immediately.
If you have followed the steps in the user’s manual, but still have symptoms that don’t seem to match
your test results, contact your Healthcare Professional or physician immediately. If you have questions
regarding the use of the meter, please call the Customer Care Service toll-free at 866-994-3345 (Eastern
Standard Time, Mon-Fri 8:00AM~6:00PM). During non-service hours, please contact your healthcare
provider.
Please read your test strip instructions carefully for additional health-related information.
Table of Contents
Chapter 1: Understanding Your Meter ….......................................................................................................11

The EGV1.1 Blood Glucose Meter ….........................................................................................................11
The EGV1.1 Accessories............................................................................................................................13
Inserting Batteries......................................................................................................................................14
Setting The Time and Date - First Time Use..............................................................................................15
Using EGV1.1 Blood Glucose Test Strips ..................................................................................................16
Chapter 2: Control Solution Testing..............................................................................................................17
Why Run a Control Solution Test ...............................................................................................................17
About the Control Solutions ......................................................................................................................18
Running a Control Solution Test ................................................................................................................19
Understanding Control Solution Test Results ............................................................................................21
Chapter 3: Testing Your Blood Glucose .......................................................................................................23
Using the Lancing Device .........................................................................................................................23
Inserting a Lancet into the Lancing Device ................................................................................................24
Running a Blood Glucose Test with Blood from Your Fingertip .................................................................26
Alternative Site Testing (AST)……...……………….…………………………………………………………….28
Running a Blood Glucose Test with Blood from Your Forearm ……..........................................................30
Running a Blood Glucose Test with Blood from Your Palm ……...............................................................31
Discarding Used Lancets …......................................................................................................................32
Understanding Your Test Results - Expected Values………......................................................................33
Unusual Test Results…..............................................................................................................................33
Comparing Your Meter Result to Lab Results …........................................................................................34

Chapter 4: Meter Memory, Setup …...............................................................................................................35
Memory, Storing Test Results …................................................................................................................35
Viewing & Deleting Test Results….............................................................................................................36
Chapter 5: Maintenance and Troubleshooting ….........................................................................................37
Inserting Batteries …..................................................................................................................................37
Cleaning and Disinfecting Your Meter and Lancing Device....……...........................................................38
Cleaning and Disinfection Frequency.........................................................................................................40
Maintenance and Testing ...........................................................................................................................42
Screen Messages and Troubleshooting ….................................................................................................43
Chapter 6: Technical Information …..............................................................................................................48
Specifications ….........................................................................................................................................48
Limitations…...............................................................................................................................................49
Accuracy Study………………………….................................................................................................51
Device Information ….................................................................................................................................53
Warranty ...................................................................................................................................................53
Table of contents