Epic Fans Brevis User manual

User’s Manual
Installation, Operations,
Maintenance and Parts
Part No. 6022110A
Do not install, operate or service this product unless you
have read and understand the Safety Practices, Warnings,
and Installation and Operating Instructions contained in
this User’s Manual. Failure to do so could result in death
or serious injury.
This manual applies to fans
manufactured beginning March
2019.
Brevis 3 Blade HVLS Fan
User’s Manual
E506041

2 6022110A — 3 Blade HVLS Fans April 2019
You may nd safety signal words such as DANGER, WARNING, CAUTION or NOTICE throughout this User’s
Manual. Their use is explained below:
SAFETY SIGNAL WORDS
Introduction.................................................................2
Safety Signal Words ..................................................2
Safety Practices..........................................................3
Owner’s Responsibilities ............................................5
Hardware....................................................................6
Fan Kit ........................................................................7
Installation Considerations .........................................8
Installation ................................................................12
Components and Specications...............................19
table of contents
Operating Instructions ..............................................20
Planned Maintenance...............................................21
Troubleshooting Guide .............................................22
VFD Fault Codes......................................................23
Fire Control System Fan Shutdown..........................25
Electrical Schematics ...............................................28
Parts List...................................................................31
Warranty Information ................................................32
Distributor Information ..............................................32
INTRODUCTION
Welcome and thank you for choosing this 3-Blade HVLS fan from Epic Fans.
This User’s Manual contains information that you need to safely install, operate and maintain the fan. It also
contains a complete parts list and information about ordering replacement parts. Please keep and read this User’s
Manual before using your new fan.
WARNING AND CAUTION SYMBOL
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL
PERSONAL INJURY HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW
THIS SYMBOL TO AVOID POSSIBLE DEATH OR INJURY.
DANGER SYMBOL
INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED,
WILL RESULT IN DEATH OR SERIOUS INJURY
ELECTRICAL WARNING SYMBOL
INDICATES AN ELECTRICAL HAZARD WITH A MEDIUM LEVEL OF RISK THAT
COULD RESULT IN DEATH OR SERIOUS INJURY.

April 2019 6022110A — 3 Blade HVLS Fans 3
CAUTION SYMBOL
INDICATES A POTENTIALLY HAZARDOUS SITUATION, WHICH IF NOT AVOIDED
MAY RESULT IN MINOR OR MODERATE INJURY.
WARNING SYMBOL
INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED,
COULD RESULT IN DEATH OR SERIOUS INJURY.
NOTICE SYMBOL
NOTICE IS USED TO ADDRESS PRACTICES NOT RELATED TO PERSONAL
INJURY.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
READ THESE SAFETY PRACTICES BEFORE INSTALLING, OPERATING, OR
SERVICING THE FAN. FAILURE TO FOLLOW THESE SAFETY PRACTICES
COULD RESULT IN DEATH OR SERIOUS INJURY.
READ AND FOLLOW THE OPERATING INSTRUCTIONS IN THIS MANUAL
BEFORE OPERATING THE FAN. IF YOU DO NOT UNDERSTAND THE
INSTRUCTIONS, ASK YOUR SUPERVISOR TO TEACH YOU HOW TO USE THEM
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE
BRACKETS WHEN INSTALLING THE BRACKETS OR CLEANING THE FAN. DO
NOT INSERT FOREIGN OBJECTS IN BETWEEN ROTATING FAN BLADES.
TO REDUCE THE RISK OF FIRE, HVLS FAN MOTOR ASSEMBLIES MUST BE
INSTALLED WITH THE BLADE ASSEMBLIES THAT ARE MARKED ON THEIR
CARTONS TO INDICATE THE SUITABILITY WITH THIS MODEL. OTHER BLADE
ASSEMBLIES CANNOT BE SUBSTITUTED.
BE CERTAIN TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL.

4 6022110A — 3 Blade HVLS Fans April 2019
INSTALLATION OF THE EQUIPMENT MUST COMPLY WITH LOCAL AND NATIONAL
ELECTRICAL CODES AND MUST BE IN ACCORDANCE WITH ANSI/NFPA 7-1999.
DO NOT USE THIS INDUSTRIAL FAN UNTIL YOU HAVE RECEIVED PROPER
TRAINING. IMPROPER USE COULD RESULT IN PROPERTY DAMAGE, BODILY
INJURY AND/OR DEATH. READ AND FOLLOW THE COMPLETE OPERATING
INSTRUCTIONS ON PAGES 20AND 21 BEFORE USE. IFYOU DO NOT UNDERSTAND
THE INSTRUCTIONS, ASK YOUR SUPERVISOR TO EXPLAIN THEM TO YOU OR
CALL YOUR LOCAL DISTRIBUTOR.
DO NOT USE THE FAN IF IT APPEARS DAMAGED OR DOES NOT OPERATE
PROPERLY. INFORM YOUR SUPERVISOR IMMEDIATELY.
DO NOT OPERATE THE FAN UNTIL ALL PERSONNEL, BUILDING STRUCTURE,
AND EQUIPMENT ARE CLEAR OF ALL MOVING PARTS AND EXCLUSION ZONES.
INSTALL GUARDS AS REQUIRED.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE TO WATER OR
RAIN.
SUPPORT DIRECTLY FROM BUILDING STRUCTURE. DO NOT INSTALL THE
FAN UNIT ONTO STRUCTURE OF INSUFFICIENT STRENGTH. CONSULT
A PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. IMPROPER
INSTALLATION OF THE FAN COULD RESULT IN DEATH OR SERIOUS INJURY.
BEFORE SERVICE, INSPECTION, OR CLEANING, MAKE CERTAIN THE POWER IS
DISCONNECTED AND PROPERLY LOCKED OUT.
IF THE FAN DOES OPERATE PROPERLY USING THE PROCEDURES IN THIS
MANUAL, BE CERTAIN TO REMOVE POWER FROM THE UNIT AND LOCK-OUT
THE DISCONNECT ON THE POWER CIRCUIT. CALL YOUR LOCAL DISTRIBUTOR
FOR SERVICE.
KEEP YOUR BODY CLEAR OF MOVING PARTS AT ALL TIMES.
ALL ELECTRICAL TROUBLESHOOTING AND REPAIR MUST BE DONE BY A
QUALIFIED TECHNICIAN AND MEET ALL APPLICABLE CODES.
IF IT IS NECESSARY TO MAKE TROUBLESHOOTING CHECKS INSIDE THE VFD
BOX WITH THE POWER ON, USE EXTREME CAUTION. DO NOT PLACE FINGERS
OR UN-INSULATED TOOLS INSIDE THE ENCLOSURE. TOUCHING WIRES OR
OTHER PARTS INSIDE THE ENCLOSURE COULD RESULT IN ELECTRICAL
SHOCK. DEATH, OR SERIOUS INJURY.
VARIABLE FREQUENCY DRIVE (VFD) FAN CONTROLLERS CONTAIN HIGH
VOLTAGE CAPACITORS. BEFORE WORKING ON THE FAN CONTROLLER,
ENSURE ISOLATION OF THE MAIN VOLTAGE SUPPLY AND VERIFY VOLTAGE
HAS BLED OFF PRIOR TO BEGINNING WORK. FAILURE TO DO SO MAY RESULT
IN DEATH OR SERIOUS INJURY.
IF YOU HAVE PROBLEMS OR QUESTIONS, CONTACT YOUR LOCAL DISTRIBUTOR
FOR ASSISTANCE.

April 2019 6022110A — 3 Blade HVLS Fans 5
TO REDUCE THE RISK OF INJURY TO PERSONS, INSTALL FAN SO THAT THE
BLADE IS AT LEAST 3.05M (10') ABOVE THE FLOOR.
INSTALLATION WORK AND ELECTRICAL WIRING MUST BE DONE BY QUALIFIED
PERSON(S) IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS.
WHEN CUTTING OR DRILLING INTO WALL OR CEILING, DO NOT DAMAGE
ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.
EXERCISE CAUTION AND COMMON SENSE WHEN POWERING THE FAN. DO NOT
CONNECT THE FAN TO A DAMAGED OR HAZARDOUS POWER SOURCE. DO NOT
ATTEMPT TO RESOLVE ELECTRICAL MALFUNCTIONS OR FAILURES ON YOUR
OWN.
WHEN SERVICE OR REPLACEMENT OF A COMPONENT IN THE FAN REQUIRES
THE REMOVAL OR DISCONNECTION OF A SAFETY DEVICE, THE SAFETY DEVICE
IS TO BE REINSTALLED OR REMOUNTED AS PREVIOUSLY INSTALLED.
RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS DURING CLEANING
AND USER-MAINTENANCE. DISCONNECT THE FAN FROM THE POWER SUPPLY
BEFORE SERVICING.
STAY ALERT, WATCH WHAT YOU ARE DOING, AND USE COMMON SENSE
WHEN INSTALLING FANS. DO NOT INSTALL FANS WHEN TIRED, OR UNDER
THE INFLUENCE OF DRUGS, ALCOHOL, OR MEDICATIONS. A MOMENT OF
INATTENTION WHILE INSTALLING FANS MAY RESULT IN SERIOUS PERSONAL
INJURY.
THE INSTALLATION OF THIS FAN REQUIRES THE USE OF SOME POWER TOOLS.
FOLLOW THE SAFETY PROCEDURES FOUND IN THE OWNER'S MANUAL FOR
EACH OF THESE TOOLS AND DO NOT USE THEM FOR PURPOSES OTHER THAN
INTENDED BY THE MANUFACTURER.
OWNER’SRESPONSIBILITIES
The owner’s responsibilities include the following:
The owner should recognize the inherent danger of the interface between the 3 Blade fan and shop worker. The owner
should, therefore, train and instruct operators in the safe use of the 3 Blade fan.
Nameplates, cautions, instructions and posted warnings shall not be obscured from the view of operating or maintenance
personnel for whom such warnings are intended. Warnings which are worn or non-legible should be replaced.
Manufacturer’s recommended periodic maintenance and inspection procedures in eect a t d ate o f s hipment s hall be
followed, and written records of the performance of these procedures should be kept.
3 Blade fans that are structurally damaged or have experienced impacts from external sources, shall be removed from
service, inspected by the manufacturer’s authorized representative, and repaired as needed before being placed back in
service.
The owner shall see that all nameplates and caution and instruction markings or labels are in place and that the
appropriate operating and maintenance manuals are provided to users.
Modifications or alterations of 3 Blade fans shall be made only with written permission of the original manufacturer.

6 6022110A — 3 Blade HVLS Fans April 2019
HARDWARE
(x4) 1/2-13UNC x 2-1/2
Mount ─ Building
(x4) 1/2-13UNC lock nut
Guy wire assembly
Safety cable
(x20) 3/8-16UNC lock nut
Mount ─ Blade
Identification labels
Fan information
Fan diameter
Operating instructions
Fastener torque requirements
Description Torque Wrench size
1/2 dia mount hardware 44-48 ft-lbs. 3/4 hex
3/8 dia blade mount hardware 24-28 ft-lbs. 9/16 hex
Cable clamp, guy wire Secure tight 5/16 nut driver
Cable clamp, safety cable Secure tight 1/2 nut driver
(x4) 1/2-13UNC x 1-1/4 bolt
(x4) 1/2-13UNC lock nut
Mount ─ Motor frame
(x2) 1/2-13UNC x 4-1/2 bolt
(x4) 1/2 dia. washer
(x2) 1/2-13UNC nyloc lock nut
Mount ─ Assembly
NOTE:
Additional spare hardware is provided as a courtesy.

April 2019 6022110A — 3 Blade HVLS Fans 7
PACKING KIT (Standard)
1. Blade Box – 3 each
2. Fan Motor Box
a. Motor/gearbox assembly.
b. Mounting hardware. See page 5.
c. VFD box.
REQUIRED TOOLS
• Wrenches: 9/16, 3/4 (x2), 1/2
• Sockets: 1/2, 9/16, 3/4
• Nut drivers: 5/16
• Torque wrench: 15-60 Ft-lbs (for use with sockets)
• Wire strippers
• 1/4" cable cutter
• Tape measure
• Spirit level, short
• Gloves
•For laminated wood beam installs, a drill and 1/2" dia.
drill bit are required.
PRIOR TO FAN INSTALLATION:
1. Ensure that the supplied voltage matches the fan
voltage. A label containing voltage information specic
to the individual fan is located on the side of the VFD
box.
2. Ensure all mounting hardware shown on page 5 is
present.
FAN KIT
NATIONAL FIRE PROTECTION
ASSOCIATION STANDARD
In accordance with NFPA 13 Standard from the National Fire
Prevention Association as referenced in sections 12.1.4 and
11.1.7: High Volume Low Speed (HVLS) Fans: The installation
of HVLS fans in buildings equipped with sprinklers, including
ESFR sprinklers, shall comply with the following:
• The maximum fan diameter shall be 24 feet (6.1 m).
• The fan shall be approximately centered between four
adjacent sprinklers.
• The vertical clearance from the fan to sprinkler deector
shall be a minimum of 3 feet (0.9 m).
• All fans shall be interlocked to shut down immediately
upon receiving a water ow signal from the alarm system
in accordance with the requirements of NFPA 72- National
Fire Alarm and Signaling Code.

8 6022110A — 3 Blade HVLS Fans April 2019
INSTALLATION CONSIDERATIONS
ROOF SLOPE
NOTE:
For roof angles in excess of 20°, consult factory. The extension
lengths shown are minimum recommendations only, based
solely o roof pitch and fan diameter. Other considerations
must be evaluated when determining extension requirements,
such as placement of lights, sprinkler systems, HVAC
systems, etc. In addition, OSHA requirements state that fan
blades must be a minimum of 10' above the oor.
NOTE:
All fan blade parts must be greater
than 3' from all obstructions
including lights, cables, sprinklers
and other building components and
greater than one (1) fan diameter
from any wall to blade tip.
Failure to maintain exclusion
zones outlined on pages 7,
8 and 9 could result in fan
failures, including blade
separation, which could result
in death or serious injury.
DO NOT operate fans when
physical obstructions or HVAC
air ows extend into exclusion
zones. Regularly inspect fans
to ensure exclusion zones
remain clear of interference
before operating fan.
*Consult factory for assistance with fan placement and extension selection.
Fig. 1
300
300
300
Roof Slope* 2/12 4/12
Roof Angle* 9.5° 18.4°
Fan Diameter (Ft)
12 5 76
16 8 10
20 10 12
Hanging
Weight
(Lb)
Maximum
Torque
(Ft. Lb)
165
170
180
0
0
5
6
7
3/12
14.0°
9
11
Blade length (In.)
45.16
69.16
93.16
Distance from ceiling (Ft)

April 2019 6022110A — 3 Blade HVLS Fans 9
INSTALLATION CONSIDERATIONS,continued
CLEARANCE FROM HVAC EQUIPMENT
For applications near HVAC equipment (diusers, radiant
heaters, exhaust fans, louvers, etc.), the HVLS fan must be
installed at minimum distances.
• Fans located at or above HVAC equipment must have
a minimum clearance of greater than or equal to 1 fan
diameter. See Fig. 2.
• Fans located below HVAC equipment must have a minimum
clearance of greater than or equal to 2 fan diameters. See
Fig. 3.
Failure to maintain exclusion zones outlined on pages
7, 8 and 9 could result in fan failures, including blade
separation, which could result in death or serious injury.
DO NOT operate fans when physical obstructions or
HVAC air ows extend into exclusion zones. Regularly
inspect fans to ensure exclusion zones remain clear of
interference before operating fan.
Fig. 2
Fig. 3
Greater than
1 fan dia.
Greater than
2 fan dia.

10 6022110A — 3 Blade HVLS Fans April 2019
Failure to maintain exclusion zones outlined on pages
7, 8 and 9 could result in fan failures, including blade
separation, which could result in death or serious injury.
DO NOT operate fans when physical obstructions or
HVAC air ows extend into exclusion zones. Regularly
inspect fans to ensure exclusion zones remain clear of
interference before operating fan.
CLEARANCE FROM SOLID OBSTRUCTIONS
For applications near solid obstructions the HVLS fan must
be installed at minimum distances.
• Fans located above solid obstructions such as racks, walls,
etc. must have a minimum vertical clearance of greater than
or equal to 1/2 fan diameter above and less than or equal
to 1/4 fan diameter inside the fan blade arc. See Fig. 4.
Fig. 4
INSTALLATION CONSIDERATIONS,continued
Greater than
1/2 fan dia.
Less than
1/4 fan dia.
Greater than
1/2 fan dia.
Table of contents
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions