04 Safety
Never modify the fan or electronics•
Do not store inammable products in the vicinity of this product•
This appliance is not intended for use by persons (including children) with•
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
For a bathroom application the power supply should be installed outside the•
bathroom as it is 230V.
This unit draws air in from atmosphere and you must ensure that any emissions•
from any other systems such as gas or oil boilers, do not contaminate the air
entering the heatSava product. Therefore, before installation, consider where
the external cowl will be located in relation to any boiler ues etc. Externally,
we recommend that the unit to be positioned a minimum distance away of; 1
metre horizontally, 1 metre below or 3 metres above any boiler ue etc. Also
refer to Building Regulations, Document J – Combustion Appliances & Fuel
Storage Systems.
In kitchens, if the unit has to be tted above a cooker, it should be installed a •
minimum distance of 650mm above electric cookers and 750mm above gas
cookers, and not have a pullcord tted.
Be sure to have read and understood these instructions before
beginning the installation process. Electrical Assembly
When wiring the unit in, a suitable disconnect device such as
a switched fused spur should be used, do not use a plug. The
means of disconnecting the unit from the mains power supply
must be incorporated in the xed wiring in accordance with the
wiring rules.
There must be a necessity to allow disconnection of the
appliance from the supply after installation, unless the appliance
incorporates a switch complying with the wiring rules. The
disconnection may be achieved by incorporating a switch in
the xed wiring in accordance with the wiring rule.
The electrical install comprises of a power supply unit (Fig.1) or a
low voltage box - SELV (Fig.2). The 2 and 3 core cables are to be
supplied by the installer. See pages 21-22 for wiring diagrams..
Connect 3 core
cable into unit
Connect 2 core cable
from SELV box into unit
Connect 3 core
cable into SELV
3 core2 core
SELV Box
Fan
Board
Power
Supply
SELV
MAINS
Fig.1
Fig.2
IPX4 Rated
This unit has been tested to IPX4 and is suitable for installation
within Zone 1 of bathrooms. However, we recommend that
you must position the unit above any water devices such
as taps, showerheads or jets and ensure water is not aimed
directly at the unit. Do not use jets or shower heads etc to
clean this unit.