Environmental MIJ-12 User manual

MIJ-12
The Water Proof Logger Manual
Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844

SM150T・ML3
Sig-
Sig+
GND
GND
+2.5V
+12V
SM150T
ML3
Soil Moisture Snesors
(Simultaneous temperature measurement requires 2 channels, so
temperature measurement is not possible with MIJ-12)
(For the EC5, please be careful not to connect the preheat to 12V )
EC5
10HS
Dendorometers
MIJ-02 Type3 Rotary
Sig-
Sig+
GND
GND
+2.5V
+12V
MIJ-02 Type2 LMS
MIJ-02 Type2 LMM
Sig-
Sig+
GND
GND
+2.5V
+12V
EC5・10HS
Sig-
Sig+
GND
GND
+2.5V
+12V
Typical sensor that require preheat
Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
MIJ-12 The Water Proof Logger Manual
Unpacking
・IP68 Case
・LR5041 or 5042 Datalogger
・PR-01(Preheat Power Supply Board;if your sensor need preheat function)
・Communication Adapter LR5091 or 5092(Only if you do not have one)
MIJ-12 is shipped fully assembled. Make sure that all of the following items are included.
MIJ-12 Preheat Version: How to wire sensor and logger
Sig-
Sig+
Sig-
Sig+
GND
GND
+2.5V
+12V
GND
PRH
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
LR5042
Connect sensor to PR-01
Sensors
Connect Logger (LR5042) to PR-01
・Connect voltage inputー(black)to Sig-
・Connect voltage input+(red)to Sig+
・Connect GND (for preheat; white) to GND
・Connect Preheat (yellow) to PRH
・Silica Gel Bag
・LR9802 cable
EC5
10HS

Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
Preheatless version does not use logger
preheat (white) and (yellow) wire.
MIJ-12 Preheat Less Version: How to wire Sensor and Logger
PR-01Sensor Preheat Power Supply Board
記録
ー+停止
確定 ー+
LR5041
I will explain how to wire the MIJ-12 preheatless. No PR-01 base is required as it does not require
preheating.
①
②
××
Sensors
MIJ-14/K2
PAR Sensor Soil Oxygen sensor
記録
ー+停止
確定 記録
ー+停止
確定
LR5041
×
×
記録
ー+停止
確定 記録
ー+停止
確定
LR5041
×
×
Sig-
Sig+
Sig-
Sig+
GND
GND
+2.5V
+12V
GND
PRH
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
Sig-
Sig+
Sig-
Sig+
GND
GND
+2.5V
+12V
GND
PRH
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
[2.5V&12V]
SM150T、ML3、EC5,10HS etc. EMJ Dendrometer
There is a red sticker on the board of [5Vと12V]
[5V&12V]
The PR-01 is a board that supplies the necessary power to the sensor from 4 AA batteries.The PR-01 has
two types of voltage output, [2.5V and 12V] or [5V and 12V], so you can choose according to the sensor.
The instantaneous capacity of each voltage output is 80mA. For general use, the preheat time is 1 second
and the interval is 10-30 minutes. When using AA alkaline batteries, the capacity is 2000mAh, so generally
four AA alkaline batteries can drive the sensor for over a year.
Typical sensor that do not require preheat

Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
Caution
Trouble Shooting
1:PR-01 not working?
No data available
・Are the battery polarities correct? (Battery polarity +,- may be inserted in the opposite direction by mistake.)
・Press the record button on the logger and try to move the sensor (for a soil moisture meter, grab the pin, etc.), and
will the PR-01 LED light up at that time?
・Try shorting PR-01's GND and PRH with tweezers. Does the LED light up at this time?
・If there are no problems with all of the above, it can be said that the PR-01 is almost not broken.
We recommend replacement for obvious failures that can be found without the above tests (the base is clearly
rotten, etc.).
Desiccant Opend
when insyalled
Desiccant Opend
when insyalled
Please note the following when using the MIJ-12 in the field.
・Open the zipper of the included silica gel and reinsert it into the MIJ-12.
・Tighten the cover of MIJ-12 tightly.
Sig-
Sig+
Sig-
Sig+
GND
GND
+2.5V
+12V
GND
PRH
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
2.Are the LR5042 settings correct?
・Is the LR5042's preheat set to OFF?
If you are using a sensor that requires preheating, be sure to set the preheating to 1 second (recommended).

Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
3. Is there any remaining battery for PR-01 or Logger?
If you still have problems after solving 1 to 3, please contact us.
Trouble Shooting
記録
ー+停止
確定 記録
ー+停止
確定
LR5042
記録
ー+停止
確定 記録
ー+停止
確定
LR5042
記録
ー+停止
確定 記録
ー+停止
確定
LR5042
Sig-
Sig+
Sig-
Sig+
GND
GND
+2.5V
+12V
GND
PRH
replace with new battery
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
AA Battery
+
ー
Setting:Logger LR5042 or LR5041
Basically, the following contents are set at the time of shipment.
・Rec Interval:10min
・Start method:Button operation
・Stop method:Button operation (One-time)
・Rec mode: instantaneous
・Preheat:1sec (Only if your sensor need preheat)
1.Plug the communication adapter LR5091 or LR5092 into your PC USB port.
2.The LR5000 Utility screen will appear on your PC. Please change various settings arbitrarily in the
recording method tab.(The factory setting is recommended.)
How to set

3.Click the measurement method tab to set preheat ON/OFF.
Note: Please set preheat to OFF when using the MIJ-12
preheatless version.
If you use the MIJ-12 preheat version, set the preheat option. (We recommend 1 second.)
4.Finally, click the Submit Settings button to complete.
Please refer to the HIOKI website for details of functions.
https://www.hioki.com/global/products/compact-data-loggers/compact/id_5920
Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
Setting:Logger LR5042 or LR5041
Measurement start/stop/data collection
Start Measurment
1. Install the sensor. Press the Record/Stop key for more than 2 seconds. Press until “REC” appears on
the display and it stops flashing and stays lit.
記録
ー+停止
確定 ー+
0
DATA
REC
記録
ー+停止
確定 ー+
0
REC
DATA

Measurement start/stop/data collection
Stop Measurment
記録
ー+停止
確定 ー+
5.000v
00
REC
2.The measurement screen is displayed 1 second after REC lights up. Measurement is started at this time.
記録
ー+停止
確定 ー+
1391
DATA
REC
5.000v
Press the record/stop button for 2 seconds or more, and stop is completed when "REC" disappears after
blinking.
記録
ー+停止
確定 ー+
1391
DATA
5.000v
Environmental Measurement Japan, CO., LTD.
2-52-42 Takamidai, Fukuoka-city Higashiku, Fukuoka 811-0215, Japan
TEL +81-92-608-6412
FAX +81-92-985-7844
HIOKI
LR5091 COMMUNICATION ADAPTER
HIOKI
LR5091 COMMUNICATION ADAPTER
Data Collecting steps
記録
ー+停止
確定 記録
ー+停止
確定
1391
DATA
5.000v
1.Connect the LR5091 to your PC.
2.Place the LR5092 on top of the LR5091 communication adapter. (Place the LR5042 with the DISPLAY
side facing down.)
PC
PC
Please refer to the HIOKI ocial page or the attached manual for details
Table of contents