393843-2 Rev 0: 01.09.2017. BBV
We reserve the right to change technical data without notice. http://www.ensy.no Page 7
Main menu
1. Control Button indicator for fan.
2. Control Button indicator set point.
3. Control Button indicator information.
4. Control Button indicator settings.
Overview of control panel
The main screen consists of, from top, left:
Time Indication, hour, minute
Timer, Weekly schedule (if programmed)
Reheating coil (if connected)
Temperature readings, Outdoor / Indoor
Status airflow – fan speed setting
OFF MIN NORM or MAX
Temperature set point, 15 - 21 °C
Reheating coil – (here refers active element)
Rotary exchanger Indicator - (here refers
active rotary wheel)
Indicators in the menu screen:
"Sun" indicates that the rotor has
stopped, the air handling unit is in
the summer operation mode.
"Snowflake" low temperature
indicates that the air handling unit
is in defrosting mode.
"Steaming pot" and blinking fan
blades indicates that the kitchen
exhaust is activated.
"Timer" and the countdown of the
fan symbol indicate that the forced
ventilation is enabled.
From 10 up to 240 minutes
"Away" indicates when the feature
is enabled, this feature will override
timer.
"Clock over the fan symbol"
indicates that the timer is activated.
Co2 over the fan symbol" indicates
that the carbon sensor is activated.
"Exclamation point" indicates that
moisture recorded over the sensor
is higher than the set value.
May also indicate that the motion
sensor is activated if connected on
D2 signal output.
This symbol indicates that the
rotary heat exchanger is activated
and will be rotated