Page 2 ©EnOcean GmbH
Important Notes
This information describes the type of component and shall not be considered as assured characteristics.
No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are
subject to change without notice. For the latest product specifications, refer to the EnOcean website:
http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not
for the described applications, processes and circuits. EnOcean does not assume responsibility for use of
modules described and limits its liability to the replacement of modules determined to be defective due
to workmanship. Devices or systems containing RF components must meet the essential requirements
of the local legal authorities. The modules must not be used in any relation with equipment that sup-
ports, directly or indirectly, human health or life or with applications that can result in danger for peo-
ple, animals or real value. Components of the modules are considered and should be disposed of as
hazardous waste. Local government regulations are to be observed.
USB 300 and USB 300C are designed and produced as OEM products. They will be brought to
market by local OEM manufacturers. They are not considered to be finished end products in terms of
WEEE (electronic waste regulation) and CE. Product warranty, labelling, WEEE and CE declarations are
covered by the local OEM.
Packing: Please use the recycling operators known to you. By agreement we will take packing material
back if it is sorted. You must bear the costs of transport. For packing material that is returned to us
unsorted or that we are not obliged to accept, we shall have to invoice you for any costs incurred.
Important notice for users in Japan: This product is not certified as confirming to technical regula-
tions of radio law of Japan. If you use this kit in Japan, you are required by Radio Law of Japan to follow
the instructions below with respect to this product: Use this product in a shielded room or any other test
facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on
March 28, 2006, based on sub-section 1.1 of article 6 of the “Rule for Enforcement of Radio Law of
Japan”. Use this kit only after you obtained the license of “Test Radio Station” as provided in Radio Law
of Japan with respect to this product, or use of this product only after you obtained the technical regula-
tions conformity certification as provided in radio law of Japan with respect to this product. Do not
transfer this product, unless you give the same notice above to the transferee. Please note that if you
could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.

USB 300 / USB 300C / USB 300U (OEM)
User Manual
Page 4 ©EnOcean GmbH
1Introduction
USB 300 is a small USB stick which connects PC’s or smart home
servers to the world of EnOcean based radio products.
EnOcean Alliance 3D-label
available on request
USB 300 is equipped with the TCM 310 transceiver module and the
gateway controller software. It provides bidirectional EnOcean radio
protocol to devices with USB interface. Radio messages are sent and
received through a virtual serial interface (FTDI Virtual COM Port).
USB 300 provides additional information like signal strength (RSSI).

V1.3 April 2013 Page 5
Control commands can be sent, e.g. to configure repeater functionali-
ty. Further information about supported commands and the software
features can be found within the TCM 310 user manual:
http://www.enocean.com/en/enocean_modules/tcm-310
USB 300 is available for 868 MHz, 315 MHz and 902 MHz:
USB 300 (868MHz) has been CE certified and fulfils R&TTE EU
directive on radio equipment
USB 300C (315MHz) and USB 300U (902MHz) fulfils FCC / IC
requirements

USB 300 / USB 300C / USB 300U (OEM)
User Manual
Page 6 ©EnOcean GmbH
2Technical Data & Environmental Conditions
Dimensions: 66 x 23 x 9mm
(incl. transport cap 70 x 23 x 9mm)
OEM label area: 39 x 12mm
Weight: 12g
Operation temperature: 0°C - +40°C
Storage temperature: -25°C - +65°C
Operation humidity: 0% - 80% r.h.
Storage humidity: 0% - 93% r.h.
USB contact durability: 500 cycles
Max. ripple USB voltage: 50 mVpp
868 MHz version: Chip antenna (R&TTE EN 300 220)
315 MHz / 902 MHz version: Whip antenna (FCC CFR-47 Part15)
CE declaration: yes
RoHS: yes

V1.3 April 2013 Page 7
Housing:
PCB:
OEM Label
TCM 310
USB activity LED,
positions depends on HW variant
Power LED

USB 300 / USB 300C / USB 300U (OEM)
User Manual
Page 8 ©EnOcean GmbH
3Block Diagram and Protocol Layers
Sensor/
Actuator
Host
USB
Interface
FTDI Virtual
COM Port
USB<>UART
FTDI
FT232R
TCM 310
EnOcean
Gateway
Controller
USB
UART
Sensor/
Actuator
EnOcean
Radio
EnOcean
Radio
125kBit/s
USB 300
EnOcean Serial Protocol 3
Host
Controller
EnOcean Equipment Profile (EEP 2.5)
FTDI Virtual
COM Port
57,6kBit/s
8N1
RF

V1.3 April 2013 Page 9
4Documentation of Protocols and EnOcean Profiles
Plug’n play device drivers are available from USB chip manufacturer
FTDI Limited for the operating systems Microsoft Windows, Linux and
Apple Mac OS: http://www.ftdichip.com/FTDrivers.htm
If you want to develop for other host platforms, you can use or adapt
available C-source code for Linux OS from FTDI Website:
http://www.ftdichip.com/Drivers/VCP.htm
USB 300 uses EnOcean Serial Protocol 3 for control commands and
data communication. A description of ESP 3 is available at:
http://www.enocean.com/en/knowledge-base/
USB 300 is based on a TCM 310 radio module, specific features and
commands are described at:
http://www.enocean.com/en/enocean_modules/tcm-310/
The content of EnOcean radio telegrams is standardized by the EnOcean
Alliance. You will find the latest definition of EnOcean Equipment Pro-
files (EEP) at: http://www.enocean-alliance.org/

USB 300 / USB 300C / USB 300U (OEM)
User Manual
Page 10 ©EnOcean GmbH
5Additional Features of USB 300
USB 300 can be used as repeater of EnOcean telegrams; this will ex-
pand the range of radio devices. Repeater command has to be sent after
every power up. For details see ESP3 command description of
CO_WR_REPEATER within the ESP3 description:
USB 300 can filter EnOcean telegrams; this can avoid heavy data load
for the host system. For details see ESP3 command description of
CO_WR_FILTER_ADD within the ESP3 description.
USB 300 supports remote management of self-powered radio nodes.
For details see TCM 310 and ESP3 command description of RE-
MOTE_MAN_COMMAND within the ESP3 description.
USB 300 supports smart acknowledge of self-powered radio nodes.
This feature enables bidirectional communication for self-powered radio
nodes. For details see TCM 310 and ESP3 command description of
SMART_ACK_COMMAND within the ESP3 description.
USB 300 commands are defined within TCM 310 Gateway Controller and
ESP3 documentation is available at:
http://www.enocean.com/en/knowledge-base/
Hint:
For advanced analysis and protocol debugging we recommend EnOcean Developer Kit
EDK 350 with DolphinView Advanced and Sniffer Software on TCM 3x0.
Other manuals for USB 300
3
This manual suits for next models
2
Table of contents
Other EnOcean Gateway manuals
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual