ENFORCER SK-1123-SPQ User manual

Vandal Resistant Outdoor
Access Control Keypads
Manual
(SK-1123-SPQ shown)
Model
Number 2 Outputs Backlit
Keys
Proximity
Reader
SK-1123-SDQ
SK-1123-SPQ

Installation
screws
2
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Quick Installation Guide:
Mounting Diagram:
Quick Wiring Diagram:
This page is for installers looking to do a basic installation and programming of the keypad. For
more in-depth installation and programming instructions, see the Table of Contents on page 4.
SK-1123-SDQ / SK-1123-SPQ

3
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Quick Programming Guide:
This page is for installers looking to do a basic installation and programming of the keypad.
For more in-depth installation and programming instructions, see the Table of Contents on page 4.
Programming Tips:
•The master, super user, common user, visitor, duress, and user codes cannot
be the same.
•A ashing amber LED indicates the keypad is in standby mode. A solid amber LED indicates the
keypad is in programming mode.
•If the keypad is set for Auto Code Entry Mode, all codes will need to be the same number of
digits as the master code (see page 24).
Programming Instructions:
Follow the instructions below if the following covers your needs:
•A new master code.
•A single 4-digit user code for all users, and no proximity cards.*
•One output to unlock a door.
•A 3-second delay time in opening the door after the output is activated.
1. Turn off the beeping before the 1-minute power-up period ends:
12 #
2. Enter Programming Mode:
0000 **
NOTE: 0000 is the default master code.
3. Change the master code:
01 xxxx #
NOTE: xxxx is the new master code.
4. Set the user code to operate output #1 (unlock the door):
10 2 000 xxxx #
NOTE: 000 chooses user ID #000 of 1,000 possible users (000~999).
XXXX is the new user code for user ID #000.
5. Set the output #1 delay time (skip this step if the default value of 5 seconds is
acceptable):
51 3 #
NOTE: 3sets the output #1 delay time for 3 seconds.
6. Exit Programming Mode:
**
*SK-1123-SPQ only

4
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Table of Contents:
Quick Installation Guide..................................................................................................................... 2
Mounting Diagram ............................................................................................................................. 2
Quick Wiring Diagram........................................................................................................................ 2
Quick Programming Guide ................................................................................................................ 3
Table of Contents............................................................................................................................... 4
Features ............................................................................................................................................ 5
Specications .................................................................................................................................... 5
Overview............................................................................................................................................ 6
Parts List............................................................................................................................................ 6
LED Indicators and Keypad Sounds.................................................................................................. 6
Installation ......................................................................................................................................... 7
IMPORTANT NOTES ........................................................................................................................ 7
Wiring Diagram.................................................................................................................................. 8
Sample Applications .................................................................................................................... 9~10
Getting Ready to Program..........................................................................................................10~11
Programming Format and Default Programming Values................................................................. 12
System Restore............................................................................................................................... 13
Programming the Master Code ....................................................................................................... 13
Programming the Super User Code .......................................................................................... 14~15
Programming Common User Codes ......................................................................................... 15~16
Programming User Codes and Proximity Cards........................................................................ 16~17
Programming Visitor Codes for Output #1....................................................................................... 18
Programming Duress Codes ..................................................................................................... 19~20
Programming the Output Mode and Output Timing......................................................................... 21
Programming the Real-Time Clock ................................................................................................. 22
Programming the Output #1 Auto-Disable Time........................................................................ 22~23
Programming the Wrong-Code System Lock-Up ............................................................................ 24
Programming the User Code Entry Mode ................................................................................. 24~25
Programming the Keypad Sounds................................................................................................... 25
Programming the Output Relay Activation Sounds ......................................................................... 25
Programming the Amber LED Flashing during Standby Mode........................................................ 26
Programming the Door-Forced-Open Warning and Timing............................................................. 26
Programming the Door-Propped-Open Warning and Delay Time................................................... 27
Programming the Egress Delay/Warning .................................................................................. 28~29
Direct Access to Programming (DAP) ............................................................................................. 29
Notes ............................................................................................................................................... 30
User’s Guide to Operating the SK-1123-SDQ/SK-1123-SPQ.......................................................... 31
Also Available .................................................................................................................................. 32

*SK-1123-SPQ only
5
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Features:
Specications:
Operating voltage 12~24 VAC/VDC
Current draw
(at 12VDC)
Standby 66mA
Keypress 93mA
Output 1 active 99mA
Output 1 & 2 active 126mA
Total max current draw 160mA
Outputs
#1 – Form C 1A@30VDC
#2 – Form C 1A@30VDC
Key active 100mA@24VDC
Duress 100mA@24VDC
Interlock 100mA@24VDC
Tamper 50mA@24VDC
Inputs
Egress N.O. Ground
Door sensor N.C. Ground
Door inhibit N.O. Ground
Proximity reader frequency* 125kHz (EM125)
Proximity reader sensing distance* 1½” (38mm)
Operating temperature -4°~158° F (-20°~70° C)
Operating humidity 5~95% Non-condensing
IP Rating IP66
Housing material Die-cast aluminum, powder paint coating
Dimensions (including back box) 4⁄”x3⁄”x2⁄” (125x79x52 mm)
Weight 1-lb 2-oz (520g)
•Built-in proximity card reader*
•12~24 VAC/VDC Auto-adjusting operation
•Up to 1,000 possible user codes (000~999)
and/or proximity cards* programmable for
output #1 and 100 (001~100) for output #2
•Up to 50 (01~50) possible temporary visitor
codes, which can be programmed for one-
time or limited-time use (1~99 hours)
•Output #1: Form C relay, 1A@30VDC max.
•Output #2: Form C relay, 1A@30VDC max.
•Outputs #1 and #2 can be programmed to
activate for up to 99,999 seconds
(nearly 28 hours)
•Tamper output: N.C. Dry contact,
50mA@24VDC max.
•IP66 Weatherproof Rating
•Surface-mount back box included
•Keypad illuminates when a button is pressed;
backlight can be programmed for FULL,
AUTO, or OFF in standby mode
•All features are programmed directly from the
keypad: No need for an external programmer
•EEPROM Memory protects programmed
information in case of power loss
•Up to 50 (01~50) duress codes for output #1,
and 10 (01~10) for output #2
•Duress code signals a silent alarm if an
authorized user is forced to open the door
under duress
•Egress input lets users exit the premises
without keying in the code
•Door sensor input for anti-tailgating operation
•Interlocking input for connecting to a second
keypad

7 8 9
113/16”
(46mm)
21/16”
(52mm)
31/8”
(79mm)
415/16”
(125mm)
45/8”
(118mm)
6
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Overview:
LED Indicators and Keypad Sounds:
Parts List:
1x Keypad
1x Back box
2x Installation screws
3x Mounting screws
3x Mounting screw
anchors
1x Security wrench
1x Diode
1x Manual
Keypad Sounds and LEDs
Status Sounds(1) Amber LED (Center)
In programming mode –Steady ON
Successful key entry 1 Beep 1 Flash
Successful code/card* entry 2 Beeps 2 Flashes
Unsuccessful code/card* entry 5 Beeps 5 Flashes
Power up delay Continuous beeping Continuous ashing
Output relay activation(2) 1-Sec long beep –
In standby mode(3) –1 Flash/sec
System restore mode 2 Beeps Fast ashing for 2.5 min
Card*/code already stored 1 Long beep –
Real-time clock stopped after
power loss
Continuous 3 fast beeps
every 5 seconds –
NOTE:
1. Keypad sounds can be programmed ON or OFF (see page 25).
2. Output relay activation sounds can be programmed for 1-sec long beep, 2 short beeps, or OFF
(see page 25).
3. Amber LED ashing during standby mode can be programmed ON or OFF
(see page 26).
*SK-1123-SPQ only
LED Indicators
Red LED (Left) Amber LED (Center) Green / Red LED (Right)
Steady Output #2 Activated Programming mode Output #1 activated (green)
Output #1 inhibited (red)
Flashing – Standby mode Inhibit mode paused (red)

Installation
screws
7
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Installation:
IMPORTANT NOTES:
1. Find a suitable location to mount the keypad. Install it at the height at which most users will be
able to easily operate the keypad.
2. Install the back box using the included mounting screws and mounting screw anchors (if
necessary).
3. Run the wire through the wall or conduit to the back box location, then run the wire through the
back box.
4. Refer to the wiring diagram (page 8) and ensure that the backlit jumper is properly set.
5. Connect the wires to the keypad according to the wiring diagram on page 8.
6. Finish assembly by attaching the keypad to the back box with the included installation screws.
1. Always disconnect power before servicing the keypad. Do not apply power until all connection
wiring is completed.
2. The keypad must be properly grounded. Use a minimum 22AWG wire connected to the
common ground output. Failure to do so may damage the keypad.
3. Allow at least 2ft (60cm) between this and any other keypads to avoid interference.
4. All wiring and programming should be done by a professional installer to reduce the risk of
improper installation.
5. The user’s guide for this keypad is located on page 31 of this manual. Be sure to store this
manual in a safe place for future reference.
IF USING THE KEYPAD WITH A MECHANICALLY
OPERATED DOOR OR GATE, MOUNT THE KEYPAD AT
LEAST 15’ (5m) FROM THE DOOR OR GATE TO PREVENT
USERS FROM BEING CRUSHED OR PINNED. FAILURE TO
DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

Connection Terminals
Connection Terminals
Backlit
jumper
Connection Terminals
Terminal Description
12~24 VAC/VDC Connect to a 12~24 VAC/VDC
power supply. Observe polarity.
Output 1 N.C.
NO/NC/COM, relay output,
max. 1A@30VDC.
Output 1 COM
Output 1 N.O.
Output 2 N.C.
NO/NC/COM, relay output,
max. 1A@30VDC.
Output 2 COM
Output 2 N.O.
Egress Input
N.O. Pushbutton contact to
ground. Press button to activate
Output #1
8
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Key Active Output Transistor ground output, max. 100mA@24VDC. Switches to ground (-) for 10 seconds after any
button pressed.
Duress Output Transistor ground output, max. 100mA@24VDC. Switches to ground (-) to trigger a silent alarm
or other device when the user enters a duress code.
Ground (-) Common ground output.
Door Sensor Connect to an optional N.C. sensor such as a magnetic contact to monitor if a door is open or
closed. Connect to ground (-) if not used.
Output 1 Inhibit Output #1 inhibitor. N.O. input, connect to Interlock Control of second keypad if needed so that if
one keypad is used to open a door, the other is temporarily disabled.
Interlock Control Interlock Control. N.O. input, connect to Output #1 Inhibit of second keypad if needed so that if
one keypad is used to open a door, the other is temporarily disabled.
Tamper N.C. Tamper switch output, N.C. contact, max. 50mA@24VDC. Connect to the N.C. 24-hour
protection zone of an alarm if needed.
Wiring Diagram:
Jumper Settings
Jumper Position Description
Backlit
Full Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto No backlit during standby. Full backlit for 10 seconds after any button press.
Off Backlit function disabled.
Backlit
jumper

SK-1123-SDQ / SK-1123-SPQ
SK-1123-SDQ/SK-1123-SPQ
(Keypad #1)
SK-1123-SDQ/SK-1123-SPQ
(Keypad #2)
9
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Sample Applications:
Stand-Alone Door Lock:
In this application, the keypad is connected to a single door lock and an egress pushbutton.
Inter-Lock System Using Two Keypads:
In this application, two keypads are each connected to separate door locks and egress
pushbuttons. While one door is open, the other cannot be opened.
• Use an N.C. magnetic contact or some other N.C. device to detect whether a door is opened or
closed. Do this for the two doors being protected.

10
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Getting Ready to Program:
Sample Applications (continued):
Codes and/or Cards*:
The keypad can be set to be activated by users in one of three ways:
1. Keypad code only – There are ve types of keypad codes:
•Master code – Used only for entering programming mode; there can be only one master
code per keypad.
•Super user code – Can be used to activate outputs #1 and #2, or to disable (inhibit) or
enable the operation of output #1.
•User codes – Unique codes for each user to activate outputs #1 or #2.
•Visitor codes – Temporary user codes that can be assigned to visitors or temporary
workers to activate output #1; the visitor codes can be programmed for one-time use or
to expire after a set number of hours has passed.
•Duress codes – Assigned to specic users as a way to send a silent alert if forced to use
the keypad under duress.
2. Proximity card only* – Standard 125kHz (EM125) proximity cards can be used to activate
outputs #1 or #2.
3. Card* + code – For enhanced security, the user can be required to also enter a code after
tapping a proximity card. The code may be unique to each card or to a group of users, or a
common code can be used with all cards.
Security Levels:
There are four possible security levels for the keypad:
1. Card only* – The most basic, convenient level of security. Hold a previously-programmed
proximity card over the keypad to activate outputs #1 or #2 (see “Programming User Codes
and Proximity Cards” on pages 16~17).
Door-Hold-Open Mode:
1. For N.C. locking devices, connect outputs in
series with working device.
2. For N.O. locking devices, connect outputs in
parallel with locking device.
*SK-1123-SPQ only
This manual suits for next models
2
Table of contents
Other ENFORCER Keypad manuals

ENFORCER
ENFORCER SK-2323-SDAQ User manual

ENFORCER
ENFORCER Enforcer Access SK-1131-SQ User manual

ENFORCER
ENFORCER SK-983A User manual

ENFORCER
ENFORCER SK-1123-SDQ User manual

ENFORCER
ENFORCER SECO-LARM SLI SK-2612-SPQ User manual

ENFORCER
ENFORCER SK-983A User manual

ENFORCER
ENFORCER SK-1011-SDQ User manual

ENFORCER
ENFORCER SK-2323-SDQ User manual

ENFORCER
ENFORCER SK-1131-SPQ User manual

ENFORCER
ENFORCER SECO-LARM SLI SK-3133-PPQ User manual