Emotiva XPR-2 User manual

XPR-2
Stereo Reference Power Amplifier
User Manual
XPR-2

Important Safety Precautions and Explanation of Symbols
!
!
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important installation, operation, and service instructions in this manual.
The lightning ash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of uninsulated dangerous voltages within the enclosure that may be of sufcient
magnitude to constitute a risk of electric shock to the user.
Please read this manual thoroughly before attempting to install, congure, or operate the XPR-2.
After successful installation and conguration of the XPR-2, be sure to retain this manual in a safe
place for future reference.
Safety is a key component to a long lasting and trouble free installation. Please read and follow
all instructions and heed all warnings on the XPR-2 and in this manual. The vast majority of the
subsequent safety precautions are common sense. If you are not comfortable with the installation
of audio/video entertainment equipment, you should seek the services of a qualied installation
professional or call us for help.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THE
XPR-2 NEAR WATER OR IN WET LOCATIONS, DO NOT EXPOSE IT TO RAIN OR MOISTURE,
DO NOT EXPOSE IT TO DRIPPING OR SPLASHING FROM OTHER SOURCES, AND ENSURE
THAT NO OBJECTS FILLED WITH LIQUIDS (SUCH AS VASES) ARE PLACED ON IT. DOING SO
MAY RESULT IN DAMAGE TO THE UNIT AND THE RISK OF ELECTRIC SHOCK, WHICH MAY
RESULT IN BODILY INJURY OR DEATH.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER
FROM THE XPR-2. THERE ARE NO USER-SERVICEABLE PARTS INSIDE THE UNIT. REFER
ALL SERVICE TO QUALIFIED SERVICE PERSONNEL.
WARNING: DANGEROUS VOLTAGES MAY BE PRESENT AT THE SPEAKER OUTPUT
TERMINALS OF THE XPR-2 (AND ALL HIGH-POWERED AMPLIFIERS). TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT TOUCH UNINSULATED AREAS OF TERMINALS OR SPEAKER
WIRES UNLESS THE AMPLIFIER IS TURNED OFF. DO NOT SHORT THE SPEAKER OUTPUTS
OF THE XPR-2 TO EACH OTHER, OR TO OTHER EQUIPMENT, WHILE THE AMPLIFIER IS
POWERED ON; SERIOUS EQUIPMENT DAMAGE OR INJURY MAY RESULT IF YOU DO.
To reduce the risk of electrical damage, verify that no short circuits are present between terminals
and / or speaker wires before applying power.
Do not install the XPR-2 near or above any heat sources such as radiators, heating vents, or other
apparatus that produces heat. Do not block any ventilation openings or heat sinks. Avoid installing
the unit directly above other heat-producing equipment unless sufcient ventilation or forced-air
cooling is provided.
Do not install the XPR-2 in locations without proper ventilation. The XPR-2 should not be operated
on a bed, sofa, rug, or similar surface that may block vents. The unit should not be installed in an
enclosed location such as a bookcase, cabinet, or closed equipment rack unless sufcient forced-air
ventilation is provided.
Always install your XPR-2 according to the manufacturer’s instructions and only use attachments or
accessories specied by the manufacturer.
Do not install the XPR-2 on any stand, shelf, or other piece of furniture that is unable to support its
weight. If a cart is used to move the unit, use caution to avoid injury from tip-over.
Connect the XPR-2 only to power sources of the correct voltage (as shown in this manual and on
the XPR-2).

Protect power supply cables from being pinched, walked on, or otherwise damaged. Be especially careful
where the power cable enters the power outlet and the unit.
Only connect the XPR-2 to an electrical outlet or extension cord of appropriate type and rating. MOST
power strips and extension cords are NOT sufcient to safely supply the power required by the XPR-2.
Using a power source of insufcient capacity will constitute a safety risk and also seriously compromise the
performance of the XPR-2
DO NOT defeat the safety purpose of a grounding or polarized plug by removing ground pins or using
unsafe adapters. A polarized plug has two blades - one wider than the other. A grounding plug has a third
ground prong in addition to the two main conductors. The wide blade or third groundling prong is provided
for your safety. If the provided plug does not t your outlet, consult an electrician to replace your obsolete
outlet. If you replace the power cord, only use one of similar type and equal or greater current rating.
The power cable for the XPR-2 should be unplugged from the outlet during severe electrical storms, or
when unused for a long period of time.
Only replace the fuse(s) in the XPR-2 with fuse(s) of proper value and voltage rating.
WARNING: UNDER SOME OPERATING CONDITIONS, THE XPR-2 MAY CAUSE A FUSE OR
CIRCUIT BREAKER IN YOUR BREAKER PANEL TO OPEN, WHICH INDICATES THAT THE XPR-2
IS ATTEMPTING TO DRAW MORE CURRENT THAN YOUR CIRCUIT CAN SAFELY SUPPLY. IF THIS
OCCURS, DO NOT REPLACE THE BREAKER OR FUSE WITH ONE OF HIGHER RATING. DOING
SO MAY RESULT IN THE POSSIBILITY OF FIRE OR ELECTRIC SHOCK, WHICH MAY RESULT IN
SERIOUS INJURY OR DEATH.
The XPR-2 should only be cleaned as directed in the manual. Avoid spraying liquids directly onto the unit
and NEVER spray liquids into the vents. Care should be taken so that small objects do not fall into the
inside of the unit.
You should seek service for your XPR-2 by qualied service personnel if any of the following occur:
1. The power-supply cord or the plug has been damaged.
2. Objects or liquid have fallen or spilled into the vents.
3. The unit has been exposed to rain.
4. The unit exhibits a marked change in performance.
5. The unit has been dropped, or its enclosure or chassis is damaged.
WARNING: THE XPR-2 IS VERY HEAVY. THE XPR-2 SHOULD BE LIFTED BY TWO PERSONS, OR
BY ONE PERSON WITH MECHANICAL ASSISTANCE. THE XPR-2 SHOULD ONLY BE PLACED ON
TABLES, STANDS, OR SHELVES, OR MOUNTED IN RACKS, WITH A CAPACITY OF AT LEAST 200
POUNDS.
NOTE: TO COMPLETELY DISCONNECT THE XPR-2 FROM THE AC POWER MAINS, DISCONNECT
THE AC POWER CORD FROM THE AC RECEPTACLE.
NOTE: THE POWER CORD ON THE XPR-2 MUST REMAIN READILY ACCESSIBLE AT ALL TIMES.
!
CAUTION
CAUTION: TO REDUCE THE RISK
OF ELECTRICAL SHOCK, DO
NOT REMOVE COVER. NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
!
!

Page 1
XPR-2
Contents
Important Safety Precautions and Explanation of Symbols
Introduction.........................................................................................3
About This Manual..............................................................................4
Features .............................................................................................5
Unpacking...........................................................................................6
XPR-2 Front Panel .............................................................................7
XPR-2 Rear Panel..............................................................................9
Quick Start........................................................................................11
Connections......................................................................................12
Conguration and Operation ............................................................14
Care and Maintenance .....................................................................15
Specications ...................................................................................16
Troubleshooting................................................................................18
Emotiva Audio Corporation Five-Year Limited Warranty ..................20
Accessories ......................................................................................22
Notes ................................................................................................23
XPR-2 Stereo Reference Power Amplifier

Page 2
XPR-2

Page 3
XPR-2
Introduction
The XPR-2 Stereo Reference Power Amplier quite simply delivers all the raw power, superb
sound quality, cutting edge technology, and good looks that you would expect in a agship
stereo amplier from Emotiva.
The XPR-2 can effortlessly deliver 600 watts per channel into 8 ohms and 1000 watts per
channel into 4 ohms with both channels driven, at less than 0.1% THD (that’s 2 kilowatts total
into 4 ohms). At 1 watt, the distortion is a miniscule 0.0025%; and the S/N ratio is an impressive
118 dB below full power. The XPR-2’s two high efciency Optimized Class H™ power amplier
modules are powered by a massive 2.5 kVA toroidal power supply with 240,000 microfarads of
energy storage.
An advanced ARM-7 microprocessor with a custom operating system continuously monitors
operation, runs the high performance LED metering system, and controls the acoustically
transparent high-speed protection circuitry. Gold-plated, machined, heavy duty input and output
connectors ensure that signals are transferred with the utmost delity.
The XPR-2 faceplate, made of 25 millimeters of solid machined aluminum, sports a high-gloss
black nish, and is tooled and polished like ne jewelry. A smoked polycarbonate display window
conceals the LED display when it’s not engaged, and the Emotiva logo laser engraved on the
faceplate proudly proclaims the XPR-2’s place in Emotiva’s superlative new Reference amplier
line. Concealed blue accent lighting completes the picture of cool elegance and effortless
performance.
This philosophy of raw power, quality construction, and precise control is at the heart of every
component in the new Emotiva Reference Series. More important, however, is how the
XPR-2 sounds: simply superb.
The Emotiva XPR-2: classic good looks; limitless power; precise control.
Experience it for yourself.
What are you waiting for?
Happy Listening
The Emotiva Team

Page 4
XPR-2
About This Manual
This User Manual will provide you with all the information you need to get started enjoying
your XPR-2 Stereo Reference Power Amplier.
We suggest that you read through the entire manual; we kept things as short and direct as
possible. Even if you’re an expert user, you will probably nd some interesting information
and useful suggestions.
You may wish to keep a copy of this manual with your records, and record serial numbers or
other purchase information on the Notes page at the back.

Page 5
XPR-2
Features
The XPR-2 Stereo Reference Power Amplier is a truly exceptional performer. It combines
the power, reliability, and superb sound quality of a great audiophile amplier with the
features and aesthetics of a true audio showpiece.
Some of the features offered by the XPR-2 include:
• Superbsoundquality-as with all Emotiva ampliers, the XPR-2 was designed rst
and foremost to deliver outstanding sound quality.
• Massiveoutputpower-600 watts per channel (x2) into 8 ohms; 1000 watts per
channel into 4 ohms, of real continuous power; both channels driven.
• OptimizedClassH™operation-with independently tracking power supply rails,
provides better efciency and cooler operation than Class A/B (and even other types of
Class H designs), with no sacrice in sound quality.
• Hugepowersupply - with an enormous 2.5 kVA toroidal power transformer and
240,000 microfarads of energy storage, ensures stunning dynamic capabilities, and no
loss of power under virtually any signal or load conditions.
• Totallystable - with virtually all real-world speaker loads.
• Attractivestyling-which harmonizes well with virtually any audio system or room
decor. The cool blue accent illumination and blue meter LEDs complement the high-
gloss black of the front panel and trim; the accent lighting and meters can each be
independently switched off (or dimmed in multiple steps) for times when you’d rather
avoid distractions from your music or movie.
• Superheavydutyaudiophilespeakerbindingposts- with clear acrylic insulators
and heavy duty gold plated contacts; designed to accept heavy-gauge bare cables,
lugs, or banana plugs.
• High-qualitygold-platedRCAinputconnectors - ensure a perfect connection,
and provide a rock-solid connection for even heavy audiophile interconnects.
• Trueaudiophile-gradefaultprotection - is entirely transparent under normal
conditions, yet protects the amp and your other equipment from virtually all common
fault conditions.
• TriggerInputandTriggerOutput - for linking to other trigger-enabled equipment.
• UniversalAClinevoltageoperation -115 VAC or 230 VAC (auto-switching).
• Fullytransferableve-yearwarranty - ensures that you’ll be able to enjoy your
XPR-2 for years to come.
You can nd more information about the XPR-2 on our website at www.emotiva.com.

Page 6
XPR-2
Unpacking
Your XPR-2 was carefully packed and should reach you in perfect condition. If you
notice any shipping damage or other issues when you unpack it, please contact Emotiva
immediately.
Gently remove your XPR-2 from the packing carton and remove all wrappings and shipping
material.
It is important to save the boxes and all packing materials in case your power amp ever
needs to be moved or shipped back to the factory for service.
We truly value customer feedback and would like to hear from you.

Page 7
XPR-2
XPR-2 Front Panel
CH1 CH2
STANDBY PEAK DIM METER
1 2
3 4 65
1. Accent Lighting
Blue accent lighting is provided by cool, long lived LEDs.
2. Channel Status and Meter LEDs
Each channel has a single Channel Status LED (the bottom one), and a blue LED Bargraph
Meter above it. Either or both are active depending on the conguration chosen. If a fault
occurs on one or both channels of the XPR-2, the LED above the Standby button, the
Channel Status LEDs, and the LED Bargraph Meter LEDs associated with the channel that
is reporting the fault will ash red.
3. Standby Button (and Power LED)
Press to switch the amplier On; press again to return to Standby. The LED above the
button will illuminate red for Standby, blue for On, and blinking red for a Fault condition.
4. Peak Button
Press once to switch the LED Bargraph Meters into Peak Meter mode; press again to select
Peak Hold Mode.
Table of contents
Other Emotiva Amplifier manuals

Emotiva
Emotiva Gen 2 XPA-3 User manual

Emotiva
Emotiva XPA HC-1 User manual

Emotiva
Emotiva BasX PT1 User manual

Emotiva
Emotiva XSP-1 User manual

Emotiva
Emotiva XMC-1 User manual

Emotiva
Emotiva RSP-1 User manual

Emotiva
Emotiva upa-200 User manual

Emotiva
Emotiva RPA-1 User manual

Emotiva
Emotiva basX A-100 User manual

Emotiva
Emotiva XPR-1 User manual

Emotiva
Emotiva BasX A-400Z User manual

Emotiva
Emotiva USP-1 User manual

Emotiva
Emotiva XPA-1 User manual

Emotiva
Emotiva MPS-1 User manual

Emotiva
Emotiva LMC-1 User manual

Emotiva
Emotiva Gen 2 XPA-5 User manual

Emotiva
Emotiva BASX PT-100 User manual

Emotiva
Emotiva RSP-1 User manual

Emotiva
Emotiva XPA-1 User manual

Emotiva
Emotiva Ultra UPA-1 User manual





















