ELTEC IPIN-300 User manual

elektronik mainz
IPIN-300
Serial IPIN Module
Hardware Manual
Revision 3 A

© 1992 ELTEC Elektronik AG, Mainz
The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility
is assumed for inaccuracies. ELTEC reserves the right to make changes to any products to improve reliability, function or
design. ELTEC does not assume any liability arising out of the application or use of any product or circuit described in this
manual; neither does it convey any license under its patent rights nor the rights of others. ELTEC products are not authorized
for use as components in life support devices or systems intended for surgical implant into the body or intended to support or
sustain life. Buyer agrees to notify ELTEC of any such intended end use whereupon ELTEC shall detemine availability and
suitability of its product or products for the use intended.
This document contains copyrighted information. All rights including those of translation, reprint, broadcasting,
photomechanical or similar reproduction and storage or processing in computer systems, in whole or in part, are reserved.
EUROCOM is a trademark of ELTEC Elektronik AG. Other brands and their products are trademarks of their respective
holders and should be noted as such.
This document is edited and printed by:
Rev. Changes Date
Revision History IPIN-300
Editorial Team:
ELTEC Elektronik AG
Galileo-Galilei-Str. 11 Postfach 42 13 63
D-55129 Mainz D-55071 Mainz
Telephone +49(61 31) 9 18-0
Telefax +49(61 31) 9 18-1 99
0 A Preliminary 13.07.87, H.R.
1 A First Edition 26.08.87, H.R.
2 A Second Edition with IPIN-302/3 15.05.90, H.R.
3 A Third Edition,
improved device reliability,
valid for Hardware Revision 3.A 08.07.92, H.R.
H.K., U.I., J.G.

Table of Contents
Page
IPIN-300 Table of Contents
Hardware Manual III
1General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2LEB Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Installation of the Serial IPINs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Connecting to the I/O Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 The Configuration Array of IPIN-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 The Configuration Array of IPIN-302. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3 The Configuration Array of IPIN-303. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5Address Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7Serial I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.1 Baud Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.2 I/O Connectors of IPIN-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.3 I/O Connector of IPIN-302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.4 I/O Connectors of IPIN-303 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8Differences between IPIN-300 and IPIN-302/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Technical Action Request Form Sheet
Reader Comments Form Sheet

Page
Table of Contents IPIN-300
IV Hardware Manual
Tables:
Table1: I/O Functions of IPIN-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table2: Jumpers J401 to J406: TD/RD - Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table3: Address Range of IPIN-300/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table4: SCC Time Constants for x16 Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Table5: I/O Connectors (X2, X3, X4) of IPIN-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Table6: Connection of IPIN-300 to Various Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table7: Pin Assignment of 9-pin Sub-D Connectors (IPIN-300). . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table8: Connection of 9-pin to 25-pin Sub-D Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table9: I/O Connector of IPIN-302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table10: Pin Assignment of 6-pin Modular Jacks (IPIN-303). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table11: Differences between IPIN-300 and IPIN-302/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Figures:
Figure1: Block Diagram IPIN-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Figure2: Block Diagram IPIN-302/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure3: Jumper Location Diagram (Bottom View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure4: Jumper Location of IPIN-302 (Bottom View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Scope of Delivery
Description: Order No.:
IPIN-300 Scope of Delivery
Hardware Manual V
NOTE: The last letter of the order numbers refers to the hardware revision and is subject to
changes. Please contact ELTEC for information about valid order numbers.
IPIN-A300 V-IPIN-A300
Serial IPIN with 3 x cable (0.3m) 18-pin DIL to 2x9-pin Sub-D
and front panel
IPIN-A302 V-IPIN-A302
Opto-isolated serial IPIN
IPIN-A303 V-IPIN-A303
I/O for 2 x IPIN-A302
with 2x26-pin connection cable to IPIN-A302 (0.25m)

Options
Description: Order No.:
Options IPIN-300
VI Hardware Manual
NOTE: The last letter of the order numbers refers to the hardware revision and is subject to
changes. Please contact ELTEC for information about valid order numbers.
Related Products
Description: Order No.:
3 x Cable (1.5 m) 18-pin DIL to 2x9-pin Sub-D V-IPIN-Z300
and Front Panel
Documentation:
Hardware Manual IPIN-300 V-IPIN-C993
Hardware:
Connection Cable 9-pin to 25-pin Sub-D, 2 m V-CABL-A119
RxD TxD =
Connection Cable 9-pin Sub-D , 2 m V-CABL-A120
RxD TxD X
Connection Cable 6-pin to 25-pin Sub-D , 3 m V-CABL-A143
Connection Cable 6-pin to 9-pin Sub-D , 3 m V-CABL-A144
RS232 to RS422/485 Converter V-CONV-A100
Data Sheets:
Data sheet Zilog SCC Z8530 V-DTBT-A906

Warning !
This equipment generates and can radiate radio frequencies. If not installed in accordance
with the instruction manual, it may cause interference to radio communications. The
equipment has not been tested for compliance with the limits for class A computing devices,
pursuant to subpart J of part 15 of FCC rules, which are designed to provide reasonable
protection against such interference, but temporary usage is permitted as per regulations.
Operation of this equipment in a residential area is likely to cause interference, in which case
the user, at his own expense will be required to take whatever measures may be required to
shield the interference.
Unpacking Instructions
Carefully remove the board from the shipping carton.
Save the original shipping container and packing material for storing or reshipping the board.
Avoid touching integrated circuits except in an electrostatic free environment.
Electrostatic discharge can damage these circuits.
Inspect the board for any shipping damage. If undamaged, the module can be prepared for
system installation.
CAUTION
IPIN-300 Unpacking and Warning
Hardware Manual VII

Conventions
If not otherwise specified, addresses are written in hexadecimal notation and identified by a
leading dollar sign ("$").
Signal names preceded by a slash ("/"), indicate that this signal is either active low or that this
signal becomes active with the trailing edge.
Used abbreviations:
bbit
Bbyte
Kkilo, means the factor 400 in hex (1024decimal)
Mmega, the multiplication with 100 000 in hex (1 048576 decimal)
MHz 1 000 000 Hertz
Conventions IPIN-300
VIII Hardware Manual

IPIN-300 1 General Description
Hardware Manual 1
1 General Description
The IPIN-300 and IPIN-302 are single Intelligent Peripheral INterface (IPIN) modules for use
in connection with an ELTEC Local Extension Bus (LEB) base module.
The most important features of these IPINs are:
•Three Zilog Z8530 8MHz serial communications controllers (SCCs) for six high-speed,
multi-mode, multi-protocol channels with program control.
•In asynchronous mode, each channel is programmable for five to eight bits per word with
one, one and one-half, or two stop bits. The user can also select odd, even, or no parity.
•Programmable baud rate generators and digital phase-locked loops for clock recovery for
50bps up to 115 200bps in asynchronous x16 mode.
•In synchronous mode, you can select external or internal character synchronization on one
or two characters, CRC generation and checking with CRC-16 or CRC-CCITT, present to
either 1s or 0s.
•Each SCC has also an SDLC/HDLC mode with comprehensive frame-level control,
automatic zero insertion and deletion, I-field residue handling, abort generation and
detection, CRC generation and checking and SDLC loop mode operation.
•Multi-protocol operation under program control; programmable for NRZ, NRZI, or FM data
encoding.
•Vectored interrupt support with three different vectors per channel for transmit, receive, and
status interrupt sources.
•Software driver for OS-9 and UNIX, for other operating systems sample drivers available.
•In connection with an IBAM board, the user has up to 18 multi-mode high-speed serial I/O
channels in a single VME slot.
Special features of the IPIN-300:
•0 to 2Mbps in synchronous mode.
•RS232 / V 24 (X.21 bis) full modem control with a 9-pin IBM compatible Sub-D connector.
•RS422,485 / V 11 (X.21) converter available.
•500mV pico fuse to protect 12V supplied chips.
Special features of the IPIN-302:
•On-board level converter for RS232 or RS422.
•Opto-isolated channel, 500VDC isolation voltage against system, not between channels.
•Only RxD and TxD supported.
•Front panel with 12 x 6-pin modular jack for two IPIN-302s available (IPIN-A303).

1 General Description IPIN-300
2Hardware Manual
Figure1: Block Diagram IPIN-300
This manual suits for next models
1
Table of contents
Other ELTEC Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual