9
3.3.2. Keyfobs
The Prime Control System supports up to 19 keyfobs.
Step 1: Register a keyfob
1. Go to the main menu, select [9]>[1]>[2] (Programming > Devices > Keyfobs)
2. Using the arro keys select a specific keyfob and press '√ʹ. The system initiates
Registration mode.
3. Press a button on the keyfob assuring the keyfob’s LED lights up hen the button is
pressed.
4. Press the same button again.
5. When 'Save?' appears on the Control System’s LCD display, press '√ʹ.
Step 2: Set the keyfob's parameters
1. Go to the main menu, select [9]>[1]>[2] (Programming, Devices, Keyfobs)
2. Using the arro keys select a specific keyfob and press '√ʹ.
3. Set the parameters for each keyfob according to the Table 6.
Quick
Key
Option Name Description and Notes
9>1>2>2 Type Controlled or non-controlled. A controlled keyfob causes the
system to send arm/disarm e ent messages to the central station.
Non-controlled keyfobs ne er send arm messages and send a
disarm message only if the system is disarmed after an alarm
occurrence
9>1>2>3 Descriptor Descriptors help identify the de ice when you operate and
program the system. Use the / key to insert a space
9>1>2>4 KF1 B1 Assign the HA unit you want the button to control. (01–16,
or 30 for PGM output) or enter 00 to program the button’s default
function – Part arming
9>1>2>5 KF1 B2
Assign the HA unit you want the button / to control.
(01–16, or 30 for PGM output) or enter 00 to program the button’s
default function – Perimeter arming
9>1>2>6 Delete Delete a keyfob
Table 6: Parameter setting
Step 3: Testing the keyfobs
1. Go to the main display press '√ʹ.
2. Enter your Installer code (default code '1111').
3. Enter [7]>[07]>[2] (Service > Transmitters > TX Test) to initiate TX communication Test.
Revie the explanation in Detectors section.