Elditest GE4500 Series User manual

Oscilloscope Probe
Sonde pour Oscilloscope
Tastkopf für Oszilloskop
GE4500 Series - 500 MHz
GE4511
GE4521
GE4511RA
GE4521RA

ELDITEST
© 2010 All rights reserved.
Elditest is a trademark of Sefram Instruments and Systems.
Elditest products are covered by US and foreign patents, issued and pending. In-
formation in this publication supersedes all earlier versions. Specifications sub-
ject to change without notice.
For product information, sales, service and technical support:
• In North America, call +1-714-221-9330 or visit www.caltestelectronics.com
• In Europe, call +33 (0)825 56 50 50 or visit www.sefram.fr
GE4511 10x 10 10 500 0.7 1.2 6 - 22
GE4511RA 10x 10 10 500 0.7 1.2 6 - 22
GE4521 10x 10 12 480 0.73 2.0 6 - 22
GE4521RA 10x 10 12 480 0.73 2.0 6 - 22
Input Compensation
Model Attn. Imped. B/W Rise Time Length Range
R (MΩ) C (pF) (M z) (ns) (m) (pF)
Model Number & Specifications
(RA = Readout Actuator or Sense Pin)
2

ELDITEST
Elditest warrants its probes for normal use and operation within specification for a
period of one (1) year from the date of shipment (accessories and manual not in-
cluded).
In exercising its warranty, Elditest, at its option, will either repair or replace any as-
sembly returned within the warranty period. owever, this will be done only if the
product is determined by Elditest’s examination to be defective because of work-
manship or materials, and the defect is not caused by misuse, neglect, accident,
abnormal conditions of operation, or damaged by attempted repair or modifica-
tions by non-authorized facility.
The customer will be responsible for the transportation and insurance charges for
the return of products.
This warranty replaces all other warranties, expressed or implied, including, but
not limited to, any implied warranty of merchantability, fitness, or adequacy for any
particular purpose or use. Elditest shall not be liable for any special, incidental or
consequential damages, whether in contract or otherwise.
Warranty
This electronic product is subject to disposal and recycling regulations
that vary by country and region. Many countries prohibit the disposal
of waste electronics equipment in standard waste receptacles.
2002/95/EC
Made in Taiwan 3

ELDITEST
To avoid personal injury and to prevent fire or damage to the probe or any product
connected to it, review and comply with the following safety precautions.
Use of this probe or test instrument it is connected to in a manner not specified by
the manufacturers may impair protection mechanisms.
Connect to properly grounded instruments. Use only with test instruments having
their BNC input connected to earth ground. Do not connect the probe ground ter-
minal to any point which is at a potential other than earth ground.
Do not disconnect the probe from instrument during measurement. Connect the
probe to the measurement instrument before connecting the probe to the test cir-
cuit.
Do not apply to the input any potential that exceeds the maximum rating of the
probe.
Comply with the voltage derating curve. When measuring higher frequency sig-
nals, be sure to comply with the Voltage vs Frequency Derating Curve.
Do not remove probe casing. Removal of the probe’s casing may expose you to
electric shock.
Do not use if any part is damaged. All maintenance should be referred to a quali-
fied service personnel only.
Do not use in wet or explosive atmospheres.
For indoor use only.
General Safety Information
To avoid Personal Injury and Product Damage:
WARNING.Warning statements identify conditions or practices that could result in
injury or loss of life.
Symbols and Terms
CAUTION.Caution statements identify conditions or practices that could result in
damage to this product or other property.
These terms may appear in this manual:
The following symbols may appear on the product:
D
ANGER
igh Voltage
A
TTENTION
Refer to Manual
D
OUBLE
I
NSULATION
Protective
(E
ART
) T
ERMINAL
4

ELDITEST
Basic Operation
The GE4500 Series are passive high impedance voltage oscilloscope probes de-
signed and calibrated for use with general purpose oscilloscopes having an input
impedance of 1 MΩ shunted by 13 pF, however selected models may be compen-
sated for use with instruments having an input capacitance between 10 to 30 pF.
Models with RA suffix are compatible with readout function oscilloscopes that au-
tomatically detect probe attenuation and adjust their readout scale accordingly.
Probe Compensation
Proper compensation of the probe is required to assure amplitude accuracy of the
waveform being measured by matching the probe to the oscilloscope’s input ca-
pacitance. Compensation should be adjusted whenever the probe is connected to
or transferred between oscilloscopes.
Low Frequency (LF):
• Apply a 1 k z square wave to the probe or connect to the oscilloscope’s
calibrator output.
• Adjust the trimmer located on the BNC Box (LF) for a flat topped square wave
per center illustration.
Procedure:
Incorrect Correct Incorrect
WARNING.To avoid electric shock, keep fingers behind the probe’s finger guard
during use.
igh frequency ( F):
(Should seldom require adjustment, however, if adjustment is required)
• Apply a 1 M z square wave to the probe (<0.7 ns rise-time).
• Adjust trimmers located on the BNC box ( F) for a flat topped square wave per
center illustration.
Incorrect Correct Incorrect 5

ELDITEST
Attenuation Ratio . . . . . . . . . . . . . 10x (10:1) 10:1±0.5%
Bandwidth . . . . . . . . . . . . . . . . . . see table
Rise Time . . . . . . . . . . . . . . . . . . . see table
Input Resistance . . . . . . . . . . . . . . see table (used with oscilloscope with 1 MΩ input)
Input Capacitance . . . . . . . . . . . . . see table
Compensation Range . . . . . . . . . . see table
Max. Input Voltage . . . . . . . . . . . . 600 V CAT I, 300 V CAT II (DC + peak AC)
Derated with Frequency (see Derating Curve)
Pollution Degree 2
Max. Operating Temp . . . . . . . . . . 0° to +50° C
umidity . . . . . . . . . . . . . . . . . . . . 85% R or less (at 35° C)
Cable Length . . . . . . . . . . . . . . . . see table
Definitions:
Measurement Category I (CAT I) is for measurements performed on circuits not directly connected to mains.
Measurement Category II (CAT II) is for measurements performed on circuits directly connected to the low voltage in-
stallation. Examples are on household appliances, portable tools and similar equipment.
Pollution Degree 2 refers to an operation environment where normally only dry non-conductive pollution occurs
Temporary conductivity caused by condensation must be expected.
Low Voltage Directive
(LVD) 93/68/EEC
(and 73/23/EEC)
EN 61010-031:2000
Ty e C robe assembly
Specifications [EC Declaration of Conformity]
10 K z
0 V
100 V
200 V
300 V
400 V
500 V
600 V
700 V
100 K z 1 M z 1 G z10 M z 100 M z
Voltage vs Frequency Derating Curve
WARNING.Do not apply to the input any potential that exceeds the maximum
ratings of the probe .
6

ELDITEST
1 Sprung ook, 5 mm, Black CT2709A-0 1
2 GND Lead w/Alligator Clip CT2710-12-0 1
3 BNC Adapter, 5 mm CT2708 1
4 Replacement Tip, Black CT2711A-0 1
5 Deluxe Trimmer Tool CT3648 1
6 IC Tip Insulator, 5 mm, Black CT2713A-0 1
7 Tip Insulator, 5 mm, Black CT2712A-0 1
8 Identifier Rings CT3662 1
9 Probe Tip GND CT2714 1
Itm. Description Model Quantity
Replaceable Parts
GE4500
1
3
4
5
6
7
8
9
2
X10
7

Use the following guidelines:
• Clean only the exterior of the probe, cables and accessories. Use a soft cotton
cloth moistened with a mild detergent and water solution. Do not allow any
portion of the probe to be submerged at any time.
• Dry the probe and accessory thoroughly before attempting to make any voltage
measurement.
• Do not subject the probe to solvents or solvent fumes as these can cause deteri-
oration of the probe body, cables and accessories.
For Elditest oscilloscope probes:
North America:
Cal Test Electronics, Inc.
22820 Savi Ranch Pkwy.
Yorba Linda, CA 92887-4610 USA
Tel : 714-221-9330
Fax : 714-921-9849
E-mail : info@caltestelectronics.com
Web : www.caltestelectronics.com
Europe:
SEFRAM Instruments et Systèmes
32, rue E. MARTEL BP55
F 42009 – SAINT-ETIENNE Cedex 2 France
Tel : +33 (0)825 56 50 50 (0,15€TTC/mn)
Fax : +33 (0)4 77 57 23 23
E-mail : sales@sefram.fr
Web : www.sefram.fr
User Man GE4500_r04
Cleaning
ELDITEST
8

Oscilloscope Probe
Sonde pour Oscilloscope
Tastkopf für Oszilloskop
GE4500 Série - 500 MHz
9

ELDITEST
© 2010 Tous droits réservés.
Elditest est une marque déposée de Sefram Instruments et Systèmes.
Les produits Elditest font l’objet de brevets déposés ou en cours. Les informations
présentes dans ce manuel remplacent toutes les informations antérieures. Les spé-
cifications peuvent être modifiées sans préavis.
Pour obtenir des informations, le SAV ou le support technique:
• In North America, call +1-714-221-9330 or visit www.caltestelectronics.com
• En Europe, appelez le +33 (0)825 56 50 50 ou visitez www.sefram.fr
GE4511 10x 10 10 500 0.7 1.2 6 - 22
GE4511RA 10x 10 10 500 0.7 1.2 6 - 22
GE4521 10x 10 12 480 0.73 2.0 6 - 22
GE4521RA 10x 10 12 480 0.73 2.0 6 - 22
Imp Temps Compensation
Modèle Attn. d’entrée Bande de monté Longueur Gamme
R (MΩ) C (pF) (M z) (ns) (m) (pF)
Référence & Spécifications
(RA = dispositif pour readout sur l’oscilloscope)
10