5
c) Timing: no timing and is OFF.
e) ECO: ECO is disabled and LED_ is OFF.
f) Temperature: the default setting temperature is 35℃.
g) Swing: no swing, is off.
Re-press to shutdown and show 60s countdown to enter standby mode.
Note: don’t determine the temperature within 10s after power-on, and turn
off the fan at a delay of 60s after power-off.
2. power switch button:
2.1 In power-on mode, press to switch among low-gear-high-gear-hot
wind.
a) Low-gear: PTC is operated at a low-gear wind and low-gear Led_ is ON.
b) High-hear: PTC is operated at high-gear wind and high-gear Led_ is
ON. (if it switches to high-gear from low-gear, PTC is operated at
high-gear by a delay of 10s and low-gear power indicator light is OFF.)
3. set button:
3.1 In power-on mode, press SET button to set temperature.
a) Temperature setting function: press SET button to flash nixie tube.
Then, press +/- to adjust the temperature shown by nixie tube without
repetition. Temperature can be set as 5℃ to 35℃ at a step length of 1℃.
b) In temperature-setting mode, set temperature isn’t changed.
Temperature is only reset when +/- is pressed and set temperature will
become valid after exit by pressing SET button.
c) It immediately enters temperature-setting display mode after non-
operation for 5s or pressing the button other than +/- in 5s.
d) Temperature isn’t determined in 10s after power-on. When ambient
temperature exceeds set temperature after operation for 10s, turn off
heating PTC, hide heating power, stop swing (if started before), turn off
wind wheel by delay for 60s, and keep other display unchanged; when
ambient temperature is 2℃ lower than set temperature, restart PTC, wind
wheel and swing (if started before) and display heating power at the time.
e) If time and temperature are set at the same time, timing and room
temperature are displayed alternatively at an interval of 30s. if timing isn’t
set, only temperature is shown.
3.2 In temperature setting mode, re-press SET button to set timing
function.