Eaton E5-248-C1420 User manual

MN05405001E 1
español englishfrançais
deutsch
italiano
Operating Instructions
Timers
E5-248-C1420
FRONT PANEL
The key below each digit sets the Set Time on the Subsidiary Display. The red reset
key resets the unit to zero when timing up or to the Set Time when timing down.
Direction of timing is programmable. There are several annunciators as follows:
• PROG appears in programming mode
• and indicate direction of
timing
• Various segments of the suite of mode
annunciators indicate the current mode
and status at a point in time
• Relay Symbol. Indicates whether relay
contacts are open or closed
• LEVEL EDGE RETRIG indicates
triggering mode.
• HRS MIN SEC together with the decimal
point position indicates which timing
range is selected.
1234567
DESCRIPTION
This programmable timer has a two line black on silver LCD readout with the timing on
the Main Display and the Set Time on the Subsidiary Display. A wide range of modes
can be selected in programming.
CONNECTIONS
Typical Installation Wiring
Neutral
Relay
Short to inhibit
keyboard
Live
Timer Input
External Reset
Main Display
Reset Digit 5 Digit 1
Subsidiary Display
S
1Common for terminals 2 + 3
2Timing input.
Programmable
to level or edge
triggered
These inputs can
be 12-240V AC or
DC. For DC input
the polarity is
unimported
3Reset input
4/5 Voltage free relay contacts.
Programmable to NO or NC
6/7 Connect together to disable front
panel keys

2MN05405001E
BATTERY REPLACEMENT
Slide the cover backwards off the top of the timer to gain access to the two ½AA
lithium cells. Lift out each cell and observe the polarity sign on the PCB beneath it.
Ensure that the replacement batteries are inserted the correct way. You will need to
re-program the timer after replacing the batteries.
DO NOT THROW LITHIUM BATTERIES IN THE FIRE.
Dimensions
48 mm x 48 mm x 93 mm
(1.89" x 1.89" x 3.66")
depth including rear connector
Panel Cut-out
Square 45 +0.6 -0 mm (1.77" +0.2" -0")
Display
2 rows of 5 digits, black on silver LCD.
Upper row 6.5 mm (0.25") high
indicates Time, Lower row 3.5 mm
(0.14") high indicates Set Time.
Also mode and relay
Batteries
Two 3V ½AA Lithium batteries. 10 year
or >500,000 relay operations expected
life
Set Time
Single user selectable value within the
selected range
Accuracy
Timing
+50ms -20ms or ± 0.5% of Set Time
whichever is greater
Repeat
±0.3% of Set Time
Timing and Reset Inputs
Opto-isolated 12-240V ±10% AC or DC.
Minimum pulse width 20ms. Input
impedance 180k
Installation Category (IEC 664)
Overvoltage category II
(Pollution degree 2)
SPECIFICATIONS
Output Relay
Contacts
SPST voltage free contacts
programmable as NO or NC.
Contact Rating
8A 250V AC cosø =1
5A 250V AC cosø =0.4
8A 30V DC cosø =1
Reaction time
<20ms.
Expected life
Electrical 8A resistive load 100,000
operations
Electrical 2A resistive load 1,000,000
operations
Operating temperature
-10 to +60°C (14 to 140°F)
Storage temperature
-20 to +70°C (-4 to 158°F)
Altitude
Up to 2000m
Relative Humidity
80% max up to 31°C (88°F),
decreasing to 50% max at 40°C
(104°F)
Environmental protection
IP65 when properly installed using the
sealing gasket supplied

MN05405001E 3
english
• 1 to 99999 seconds (C3)
• 0.2 to 9999.9 seconds (B3)
• 0.20 to 999.99 seconds (A3)
• 1 to 99999 minutes (E4)
• 0.1 to 9999.9 minutes (E3)
• 0.01 to 999.99 minutes (D3)
• 1 to 99999 hours (B4)
• 0.1 to 9999.9 hours (C4)
• 0.01 to 999.99 hours (D4)
These can be displayed as elapsed time
(time up) or time remaining (time down).
Elapsed time is annunciated with
and reset is to zero.
Time remaining is annunciated with
and reset is to Preset (t, t+ or t=).
TIMING RANGE AND DISPLAY
There are nine timing ranges and against each is given (in brackets) the flowchart
display which selects it.
PROGRAMMING
To enter programming mode press and hold the Digit 1 and Digit 2 keys together for
3 seconds until the word PROG is annunciated.
The PROG annunciator appears on the display all the time in programing but has been
omitted from the flowchart for the sake of clarity. On the flowchart the annunciators are
very much bigger in proportion to the numeric digits than the real display. This is to aid
legibility.
Whenever you enter programming mode the options and values displayed are the
ones in current use. Go through all the stages in the flowchart using S to step
backwards and forwards though the options at each stage and Reset (R) to move on
to the next stage.
Line 1
Select one of 8 timing modes which, on the flowchart (only) overflows on to line 2.
Line 3
Select one of 9 timing ranges, hours, minutes or seconds and resolution. The selection
you make here determines the range in which the Time is displayed. This stage
overflows (on the flowchart only) on to line 4.

4MN05405001E
Line 5
Here the programming sequence automatically takes one of three branches. The route
it takes depends on the timing mode selected above.
For modes ON DLY, OFF DLY, SS, RC= and RC= DLY, the sequence goes to column A
on the flowchart with the appropriate annunciator showing. For these modes you need
only one Set Time. The next press of Reset goes to line 7.
Modes RC DLY and RC require 2 Set Times. Enter t+ at B5, press Reset and enter t-
at B6.
For mode OS only you enter t, press Reset and then enter a Pulse Width. Pulse Width
(C6) is always in seconds to 2 places of decimals.
Line 7
Use the S key to step though LEVEL TRIGgered, EDGE TRIGgered and EDGE
RETRIGgerable and Reset to move on.
Line 8
Select increment time (up) in which reset is to zero or decrement (down) in which reset
is to Preset (Set Time).
Line 9
Select normally open (NO) or normally closed (NC) for the relay contacts.
At the end of the sequence, accept the settings by going through all the stages again
without making any changes.
NOTE:
You can also set any of the Set Times (t, t+, t- or t=) “on the fly” during normal
operation. To do this you use the digit keys and the Set Time appears on the
subsidiary display. If the timer is running in a cyclical mode, the Set Time which
changes when you press the keys is the one being annunciated at that instant.

MN05405001E 5
english
2
1
+
(3...2...1...)
LEVEL EDGE EDGE
HRS
HRS HRS HRS
HRS HRS
HRS
MIN
MIN
MIN
MIN
MIN MIN
MIN
SEC
SEC SEC SEC
SEC
SEC SEC
SEC
R
R
R
R
RR
R
=
RE
TRIG TRIGTRIG
ABCDE
1
2
3
4
5
6
7
8
9
OFF DLY
RC
RC
RC
RC
RC
RC
+
-
=
=
OS SS
DLY
DLY
ON DLY
REPEAT WITH
NO CHANGES
The minimum time setting
is 0.2 seconds.
PROGRAMMING FLOWCHART

6MN05405001E
t
t
tt
tt t
t
t
pw
pw pw t
tt
t
tt
t
ON DLY
OFF DLY
OS
SS
TIMING
(On Delay - relay turns on after delay t)
(Off Delay - relay turns off after delay t)
(One Shot - a single pulse of length pw, after delay t)
(Single Shot - a single pulse of length t)
LEVEL TRIG
Timing Input
Reset Input Same as end of
timing input
Relay
Timing Input
Reset Input
Same as end of
timing input
Relay
Timing Input
Reset Input Same as end of
timing input
Relay
Timing Input
Reset Input
Same as end of
timing input
Relay
EDGE TRIG EDGE RETRIG

MN05405001E 7
english
13
RC DLY
RC
RC DLY=
RC=
t+
t+ t+ t+ t+
t+
t+ t+ t+ t+
t-
t- t- t-
t- t-
=t
=t
=t
=t
=t =t =t
=t
=t
=t
=t
=t
=t
=t
=t
MODES
(Repeat Cycle Delay - after delay t+, relay turns on for t- ; then repeats)
(Repeat Cycle - relay turns on for time t+, off for t-; then repeats)
(Repeat Cycle Delay - as RC DLY , but both times equal; t)
(Repeat Cycle - as RC, but both times equal; t)
Timing Input
Reset Input Same as end of
timing input
Relay
Timing Input
Reset Input Same as end of
timing input
Relay
Timing Input
Reset Input Same as end of
timing input
Relay
Timing Input
Reset Input Same as end of
timing input
Relay
LEVEL TRIG EDGE TRIG EDGE RETRIG

8MN05405001E
WARNING
Installation and maintenance must be carried out by suitably qualified
personnel only. Hazardous voltages may be present on the connection
terminals.
Installation
This product is intended to be installed in accordance with the operating and
installation requirements of Overvoltage Category II and Pollution Degree 2 (as defined
by IEC 664).
It must be fitted in a suitable enclosure which is accessible to qualified personnel only.
The relay output circuits must be fitted with fuses suitable for the voltage and current
being switched.
Maximum fuse ratings:
250V AC @ 8A cosØ= 1 fuse rating 8A
250V AC @ 5A cosØ= 0.4 fuse rating 5A
30V DC @ 8A cosØ= 1 fuse rating 8A
All conductors carrying hazardous voltage should have external switching or
disconnect mechanisms fitted which provide at least 3 mm of contact separation in all
poles.
Failure to install or operate the unit in accordance with the above requirements
may result in the electrical safety of the unit being impaired.
Maintenance
Ensure that all power sources to the unit are isolated prior to maintenance,
inspection or cleaning.
There are no user serviceable parts inside this unit. Under no circumstances should
the case be opened.
All external wiring connections should be inspected at regular intervals. Any damaged
wiring should be replaced and any loose connections should be retightened.
Cleaning should be carried out using a dry cloth to wipe the casing of the unit.
WARNING
THIS UNIT CONTAINS A LITHIUM BATTERY AND MUST NOT BE DISPOSED
OF IN A FIRE OR EXPOSED TO TEMPERATURES BELOW -20 C OR
ABOVE +70 C.

MN05405001E 9
español
Instrucciones de operación
Temporizadores
E5-248-C1420
PANEL FRONTAL
La tecla bajo cada dígito ajusta el Tiempo Fijado en la Pantalla Secundaria. La tecla
roja resetea la unidad a cero al sincronizar en dirección ascendente o al Tiempo Fijado
al sincronizar en dirección descendente. La dirección de temporización es
programable. Hay varios anunciadores como se indica a continuación:
• PROG aparece en el modo de
programación
• y indican la dirección de
temporización
• Varios segmentos del conjunto de paneles
de regulación de los anunciadores del
modo indican el modo actual y el estado
en un punto en el tiempo.
• El símbolo de Relé indica si los contactos
de relé están abiertos o cerrados
• LEVEL EDGE RETRIG indican el modo
de disparo.
• HRS MIN SEC junto con el punto decimal
indican qué intervalo de tiempo ha sido
seleccionado.
1234567
DESCRIPCIÓN
Este temporizador programable tiene una lectura de doble línea negra sobre fondo de
color plata de LCD con la temporización en la Pantalla Principal y el Tiempo Fijado en
la Pantalla Secundaria. Se puede seleccionar una amplia gama de modos en la
programación.
CONEXIONES
Cableado de instalación típica
Neutro
Relé
Poner en Cortocircuito
para inhibir el teclado
Tensión
Entrada
de Tiempo
Reset Externo
Pantalla principal
Tecla de reset Dígito 5 Dígito 1
Pantalla
secundaria
S
1Entrada común de Tiempo y de Reset.
2Entrada de Tiempo.
Programable a
nivel o margen
disparado.
Estas entradas
pueden ser de
12-240V CA o CC
Para la entrada de
CC la polaridad no
es importante.
3Entrada de reset.
4/5 Contactos de relé libres de tensión.
Programables a NO (normalmente
abierto) o NC (normalmente cerrado).
6/7 Conectar entre sí para desactivar las
teclas del panel frontal.

10 MN05405001E
CAMBIO DE LAS PILAS
Deslice la cubierta hacia atrás en la parte superior del temporizador para obtener
acceso a las dos pilas de ½AA de litio. Levante cada pila y observe el signo de
polaridad en el PCB debajo. Asegúrese de que inserta correctamente las pilas de
recambio. Necesitará volver a programar el temporizador después de reemplazarlas.
NO DESECHE LAS PILAS DE LITIO INCINERÁNDOLAS.
Dimensiones
48 mm x 48 mm y 93 mm de
profundidad incluyendo el conector
posterior
Recorte del panel
Cuadrado 45 +0,6-0 mm
Pantalla
2 filas de 5 dígitos, negro sobre fondo
plata LCD. La fila superior de 6,5 mm
de altura indica el Tiempo, la fila
inferior de 3,5 mm de altura indica el
Tiempo Fijado. También los
anunciadores del modo y relé.
Pilas
Dos pilas de litio 3V ½AA. Duración
esperada de 10 años o >500,000 de
operaciones de relé.
Tiempo Fijado
Punto individual seleccionable por el
usuario dentro de la gama
seleccionada
Precisión
Temporización
+50ms -20ms ó ±0,5% del Tiempo
Fijado, el que sea mayor
Repetición
±0,3% del Tiempo Fijado
Entradas de temporización y de reset
Optoaisladas 12-240v ±10% CA o CC.
Mínima anchura de impulso 20ms.
Impedancia de entrada 180k
Categoría de Instalación (IEC 664)
Categoría II de sobrevoltaje
(grado de contaminación 2)
Relé de salida
Contactos
Contactos libres de tensión SPST
programables como NO (normalmente
abierto) o NC (normalmente cerrado).
Valor nominal del contacto
250VCA @ 8A cos ø= 1
250VCA @ 5A cos ø= 0,4
30VCC @ 8A cos ø= 1
Tiempo de reacción
<20ms
Duración esperada
Carga eléctrica resistiva de 8A -
100.000 operaciones
Carga eléctrica resistiva de 2A -
1.000.000 operaciones
Temperatura de funcionamiento
-10°C a +60°C
Temperatura de almacenamiento
-20°C a +70°C
Altitud
Hasta 2000m
Humedad Relativa
80% máx. hasta 31°C, disminuyendo al
50% máx. a 40 °C
Grado de protección
A IP65 cuando haya sido instalado
correctamente utilizando la junta de
estanqueidad suministrada
ESPECIFICACIONES
Table of contents
Languages:
Other Eaton Timer manuals

Eaton
Eaton TSDW1COA-1 User manual

Eaton
Eaton 3h.508 User manual

Eaton
Eaton TRL04 User manual

Eaton
Eaton Durant Eclipse Series User manual

Eaton
Eaton TRL04 Instruction manual

Eaton
Eaton TSSD1CO User manual

Eaton
Eaton TSQW1CO User manual

Eaton
Eaton AT2P Instruction manual

Eaton
Eaton easy500 Series Owner's manual

Eaton
Eaton AT18HM User manual