Dutypoint VT Booster Set User manual

VTBooster Set
O&M Manual

Table of Contents
1. Important Health & Safety Information ......................................................................................... 3
1.1 Document Conventions................................................................................................... 4
1.2 Health and Safety Information......................................................................................... 6
1.3 Operating Limits for Standard Dutypoint Systems Pumpsets ......................................... 9
2. System Information, Installation and Commissioning................................................................. 10
2.1 Booster Set Components ............................................................................................... 11
2.2 Control Panel Wiring Diagrams..................................................................................... 12
2.3 HAND/OFF/AUTO Switch Operation............................................................................. 16
2.4 Installation and Commissioning VT Booster Sets ......................................................... 17
3. User Maintenance and Troubleshooting..................................................................................... 22
3.1 Routine User Maintenance............................................................................................ 23
3.2 Troubleshooting............................................................................................................. 25
Appendix A- Grundfos CRIE Pumps O&M Details ......................................................................... 28
Ap1.1 Grundfos CR/CRI/CRN Pump O&M ......................................................................... 29
Ap1.2 Grundfos CRE/CRIE, CRNE/SPKE/MTRE/CME Controller O&M (Up to 2.2kW) ..... 30
Ap1.3 Grundfos MGE 71/MGE 80/MGE 90/MGE 132 Controller O&M (More than 2.2kW) 31
Page 2VT Booster Set

1. Important Health & Safety Information
Page 3VT Booster Set

1.1 Document Conventions
Throughout this manual, text may be accompanied by one of the following icons. Where these
occur the conventions shown below are applied.
In general these conventions will also apply to OEM Manufacture’s manuals that are included
within this User Guide, however variations may occur, but these will be redefined at the beginning
of their manual.
PLEASE READ THE FOLLOWING INFORMATION WHICH IS PROVIDED FOR YOUR SAFETY
Danger: Denotes attention to the possibility of the risk of personal
injury or damage to adjacent property if the information is ignored.
Electric Shock: Denotes attention to the possibility of life-
threatening electric shock if the information is ignored.
Warning: Denotes attention to a condition that may result in under-
performance or damage to the equipment if the information is
ignored.
Page 4VT Booster Set

Note: Denotes attention to an important factor applicable to the
action being performed.
Page 5VT Booster Set

1.2 Health and Safety Information
Basic safety warnings relating to all products.
United Kingdom Health & Safety at Work Act 1974
Dutypoint Responsibility
Section 6(a) of this Act requires manufacturers to advise their customers on the safety and the
handling precautions to be observed when installing, operating, maintaining and servicing their
products. The user’s attention is therefore drawn to the following:
• The appropriate sections of this manual must be read before working on the equipment.
• Installation, operating and maintenance must only be carried out by suitably trained/
qualified personnel.
• Normal safety precautions must be taken and appropriate procedures observed to avoid
accidents.
Refer to DUTYPOINT SYSTEMS for any technical advice or product information.
Customer / Contractor Responsibility
It is the responsibility of the customer and/or the contractor:
• To ensure that anyone working on the equipment is wearing all necessary protective gear/
clothing.
• Is aware of appropriate health & safety warnings
• has read the information in this section of the manual.
Page 6VT Booster Set

Hand Control Mode
In the 'HAND' position the pump(s) controlled by the switch will normally run at full speed and
completely independently of any control devices, and can result in pump(s) running against a
closed valve head if there is no draw.
This can cause the system to be maintained at the maximum pressure produced by the pump plus
any incoming pressure and additional pressure caused by water surge and can potentially damage
the pump and other parts of the system.
The 'HAND' option should only be used with a competent operator in attendance, or when
there is a continued demand sufficient to provide constant flow through the pumps to
maintain the running pressure of the system to an acceptable level.
Pump Servicing
• Familiarise yourself with the relevant contents of this manual
• Installation, maintenance and repair work must only be carried out by trained, skilled and
suitably qualified personnel.
• Disconnect or lock-out the power source to ensure that the pump(s) will remain
inoperative. Locking out the equipment by switching off the release mechanism or
set value WILL NOT prevent accidental starting of the motor.
• Allow the pump(s) to cool if over-heated.
•CLOSE the isolating valves on the suction and discharge connections of the affected
pump(s).
•VENT the pump(s) slowly and cautiously – Refer to the relevant section of this manual.
•DRAIN the pump(s).
High Voltages
Especially applicable when Variable Speed Controllers (Inverters) are fitted.
Page 7VT Booster Set

• When the inverter variable speed drive head is connected to the power supply the components of
the power unit – as well as certain components of the master control unit – are also connected to
the power supply.
TOUCHING THESE COMPONENTS CAN SERIOUSLY ENDANGER LIFE!
• Before removing the frequency inverter cover, the system must be disconnected from the power
supply. After switching off the power supply wait at least 5 minutes before starting work on or in
the inverter drive head – the capacitors in the intermediate circuit must be given time to discharge
completely via the discharge resistors.
Up to 800 volts can be present – if there are faults this can be higher.
• All work carried out when the frequency inverter is open must be performed only by suitably
qualified and properly authorised personnel.
When connecting external control wires care must be taken not to short circuit adjacent
components. Bare cable ends which are not in use must be insulated.
THE SYSTEM MUST ONLY BE OPERATED WHEN IT HAS BEEN CORRECTLY EARTHED
AND PIPES BONDED TO EARTH IN ACCORDANCE WITH IEE REGULATIONS
Electronic Safety Devices
• High voltage tests of the inverter or the motor may damage the electronic components.
Bridge before the incoming/outgoing terminals L-L2-L3 and U-V-W.
• To avoid incorrect metering by capacitors incorporated in the electronic circuits, isolate the
motor from the inverter drive head.
High voltage testing may damage electronic components
• High voltage tests of the inverter or the motor may damage the electronic components.
Bridge before the incoming/outgoing terminals L-L2-L3 and U-V-W.
• To avoid incorrect metering by capacitors incorporated in the electronic circuits, isolate the
motor from the inverter drive head.
Page 8VT Booster Set

1.3 Operating Limits for Standard Dutypoint Systems
Pumpsets
Table showing standard operating limits which apply to cold water booster sets.
Table showing standard operating limits
Type of pumped liquids Water with no gas or aggressive substances
Maximum pumped liquids
temperature
+35°C domestic uses. (EN 60335-2-41). 40°C for other purposes
Minimum pumped liquid
temperature
1°C to avoid icing
Operating ambient
temperature
+5°C to 40°C for indoor installation. (CEI EN 60439-1).
Relative humidity Max 50% at 40°C.
Air impurities The air must be clean and free of acid vapours, corrosive gases
and excessive amounts of dust.
Storage temperature +5°C to 50°C.
Suction conditions Minimum positive pressure 0.1 Bar. Maximum positive pressure
0.5 Bar
Page 9VT Booster Set

2. System Information, Installation and
Commissioning
Page 10VT Booster Set
Table of contents
Other Dutypoint Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual