Dust Networks D2120 User manual

Dust Networks
D2120 Evaluation Kit
Quick Start Guide

D2120 EVALUATION KIT QUICK START GUIDE
Trademarks
Dust Networks, the Dust Networks logo, and SmartMesh are trademarks of Dust Networks, Inc. All third party brand and product names
are the trademarks of their respective owners and are used solely for informational purposes.
Copyright
This documentation is protected by United States and international copyright and other intellectual and industrial property laws. It is solely
owned byDust Networks, Inc. and its licensors and is distributed under a restrictive license. This product, or any portion thereof, may not
be used, copied, modified, reverse assembled, reverse compiled, reverse engineered, distributed or redistributed in any form by any means
without the prior written authorization of Dust Networks, Inc.
RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g) (2)(6/87)
and FAR 52.227-19(6/87), or DFAR 252.227-7015 (b)(6/95) and DFAR 227.7202-3(a) and any and all similar and successor legislation
and regulation.
Disclaimer
THIS DOCUMENTATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
THIS DOCUMENTATION MIGHT INCLUDE TECHNICAL INACCURACIES OR OTHER ERRORS. CORRECTIONS AND
IMPROVEMENTS MIGHT BE INCORPORATED IN NEW VERSIONS OF THE DOCUMENTATION.
EMI Warning
This equipment has been tested and found to comply with the limits pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in an appropriate installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the dealer or an experienced radio or television technician for assistance.

Contents
D2120 EVALUATION KIT QUICK START GUIDE i
1 About This Guide
Related Documents..........................................................................iii
Conventions Used..............................................................................iii
1 M2020 Evaluation Module
M2020 Evaluation Module ........................................................... 1
Connector P1.......................................................................................... 2
Connector P2.......................................................................................... 3
Serial Interface .................................................................................... 4
Power Supply......................................................................................... 4
Absolute Maximum Ratings........................................................ 4
Recommended Operating Conditions................................. 5
Wireless Specifications.................................................................. 5
Antenna ...................................................................................................... 5
Regulatory Information ................................................................ 6
2 SmartMesh Manager
Description............................................................................................... 7
Connections............................................................................................. 8
Technical Specifications................................................................ 8
Regulatory Information ................................................................ 9
3 Setting Up a Network
Setting Up the SmartMesh Manager ................................. 11
Setting Up the Network............................................................... 11

TABLE OF CONTENTS
ii D2120 EVALUATION KIT QUICK START GUIDE

D2120 EVALUATION KIT QUICK START GUIDE iii
About This Guide
This guide provides information required to successfully demonstrate the capabilities of
the D2120 Evaulation Kit. It provides various pinout and connector information for
attaching sensors to a mote Evaluation Module and instructions for setting up a network.
Related Documents
The following documents are available for a SmartMesh Network:
•D2120 Evaluation Kit Quick Start Guide (this guide)
•SmartMesh Manager Application Programming Interface (API) Guide
•Mote Integration Guide
•SmartMesh Network Planning Guide
•SmartMesh Network Administration Guide
Conventions Used
The following conventions are used in this guide:
•Computer type indicates information that you enter, such as specifying a URL.
•Bold type indicates buttons, fields, and menu commands.
•Italic type is used to introduce a new term.
dNote: Notes provide more detailed information about concepts.
bCautions: Cautions advise you about actions that might result in a loss of data.
cWarning! Warnings advise you about actions that may cause physical harm to the
hardware or your person.

CHAPTER 1 - ABOUT THIS GUIDE Conventions Used
iv D2120 EVALUATION KIT QUICK START GUIDE
Body.

D2120 EVALUATION KIT QUICK START GUIDE 1
1
M2020 Evaluation
Module
This chapter provides specifications for the M2020 Evaluation Module (M2020-EVM)
provided in the D2120 Evaluation Kit. The M2020-EVM can be used as a reference
design for integrating an M2020 Mote into a self-contained device.
M2020 Evaluation Module
The M2020-EVM consists of an M2020-A Mote, packaged with an antenna, battery
holder, status LEDs, I/O connectors, and a recessed reset switch. The M2020-EVM
board is packaged in a plastic enclosure suitable for mounting on a wall or other vertical
surface.
Figure 1-1. M2020 Evaluation Module

CHAPTER 1 - M2020 EVALUATION MODULE Connector P1
2D2120 EVALUATION KIT QUICK START GUIDE
Connector P1
Connector P1 is a 4-position terminal block connector that accepts 12–22 AWG wire. It
assumes 0 to 5 V inputs, and contains internal filter circuitry for 60 Hz noise.
cWarning: Reverse biasing these inputs may result in damage to the device.
Table 1-1. P1 Connector Pinouts
Pin
Number Pin Name I/O Description
1 A1 I Analog input 1 (0–50)
2 GND I Ground
3 A2 I Analog input 2 (0–50)
4 GND I Ground

Connector P2 CHAPTER 1 - M2020 EVALUATION MODULE
D2120 EVALUATION KIT QUICK START GUIDE 3
Connector P2
Connector P2 is an HD-15 female connector, as shown in Figure 1-2. It assumes
0 to 1.5 V analog inputs, and is unfiltered. All digital I/O are LVTTL (3 V) signaling.
Figure 1-2. HD-15 Female Connector
cWarning: Reverse biasing these inputs may result in damage to the device.
Table 1-2. P2 Connector Pinouts
Pin
Number Pin Name I/O Description
1TX OUARTTransmit
2 D5 I/O Digital I/O 5 or SOF
(see the Mote Integration Guide,
Appendix C)
3 D2 I/O Digital I/O 2
4 A7 I Analog input 7
5 A4 I Analog input 4
6 RX I UART Receive
7 D6 I/O Digital I/O 6
8 D3 I/O Digital I/O 3
9 GND I Ground
10 A5 I Analog input 5
11 D7 I/O Digital I/O 7
12 D4 I/O Digital I/O 4 or CTS
(see the Mote Integration Guide,
Appendix C)
13 D1 I/O Digital I/O 1
14 A6 I Analog input 6
15 A3 I Analog input 3
Note: All I/O, including UART, are at LVTTL (3 V) signaling levels. An external
level converter is required for RS-232 communications.

CHAPTER 1 - M2020 EVALUATION MODULE Serial Interface
4D2120 EVALUATION KIT QUICK START GUIDE
Serial Interface
Connector P2 provides a flow-controlled serial interface with timing information (using
TX, RX, CTS, and SOF), as described in the Mote Integration Guide, Appendix C.
Serial port settings are 9600 bps, 8 data bits, no parity, 1 stop bit.
Power Supply
The M2020-EVM board is powered by a pair of L91 1.5 V AA lithium batteries (or
equivalent), and comes with a standard double AA battery holder. The M2020-EVM
does not contain a power switch. Units are tested and shipped in deep sleep mode. To
place the device into deep sleep, short pins 1 and 6 on P2, and reset the M2020-EVM.
The status LEDs should remain off, and the device remains asleep until it is reset. To
activate the unit, press reset with pins 1 and 6 unconnected.
Absolute Maximum Ratings
cWarning: The M2020 Mote is an ESD-sensitive device. Use caution when handling
in order to prevent permanent damage to the device.
Table 1-3. Absolute Maximum Ratings
Parameter Min Max Units Condition
Supply voltage
VBAT (VCC)2.73.6V
Referenced to GND
Voltage on any pin –0.3 VCC +0.3 V Referenced to GND
Digital I/O current
Source
Sink
Total I/O
2
6
24
mA
mA
mA
Storage temperature –40 +85 °C
Operating ambient
temperature
–40 +85 °C
This manual suits for next models
1
Table of contents
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual