DTS INSIGHT Micom Pack FH808M07 User manual

Micom Pack
Instruction Manual
Micom Pack for Control Module
for
Flash Microcomputer Programmer
(NET IMPRESS)
FH808M07
Target Microcomputer: H8S/2612F (HD64F2612)
DTS INSIGHT CORPORATION

HF808M07 (H8S/2612F)
Revision History
Edition Date of issue Description
First Edition November 13, 2003 Initial publication
(1) No part of this manual may be reproduced, transmitted or transcribed in any form or by
any means, without the express written permission of DTS INSIGHT CORPORATION.
(2)
Information in this document may be changed without notice for purposes of
improvement and does not represent a commitment on the part of DTS INSIGHT
CORPORATION.
(3) Please contact us if you would find unclear points, questions or errors regarding the
information of this document.
(4) DTS INSIGHT CORPORATION assumes no responsibility for any damages
arising from the use or inability to use this document, or results of using the control
module.
© 2003 DTS INSIGHT CORPORATION. All Rights Reserved.
Printed in Japan
i

Contents
1OVERVIEW ........................................................................................................1
2SPECIFICATIONS................................................................................................2
2.1 TARGET MICROCOMPUTER AND SPECIFICATIONS .......................................................... 2
3COPYING WRITE CONTROL PROGRAM INTO MICROCOMPUTER ..............................3
3.1 OVERVIEW ................................................................................................................... 3
3.2 COPYING THE WRITE CONTROL PROGRAM FILE ............................................................ 4
4CONNECTING TO THE TARGET SYSTEM AND CONNECTOR .....................................5
4.1 SIGNAL LIST................................................................................................................. 5
4.2 MODEL CONNECTION TO A TARGET SYSTEM ................................................................. 6
4.3 WAVEFORM OF CONTROL SIGNAL ................................................................................. 8
5DOWNLOADING MICOM PACK ...........................................................................10
5.1 CONNECTING THE REMOTE CONTROLLER (AZ490) ..................................................... 10
5.2 DOWNLOADING MICOM PACK...................................................................................... 11
6NOTES AND CAUTIONS FOR USING CONTROL MODULE.......................................12
ii

1 Overview
The FH808M07 is the Micom Pack for the control module FH808 supporting the flash
microcomputer programmer NET IMPRESS, and contains a parameter file supporting the
microcomputer Renesas H8S/2612F.
For a Micom Pack for other microcomputers, contact us or your local distributor.
The control module supported by this Micom Pack is FH808.
CAUTION:
The Micom Pack FH808M07 is built for the specific control module FH808. Do not use this
Micom Pack with any control modules other than the specified control module.
The handling instructions are described in the Micom Pack Instruction Manual and be sure
to read this Instruction Manual carefully before you start operation.
To use the Micom Pack, you also need the remote controller AZ490 that is available for an
additional order.
For how to download the Micom Pack to the control module, see Chapter 5 “
” of this Instruction Manual.
Downloading
Micom Pack
Check once again if combination of the Micom Pack and control module is correct. Also,
check if you have a correct microcomputer, memory size, power supply, etc. Incorrect
parameter values would lead to serious damage to your microcomputer and target system.
For any questions or unclear points, please contact us.
1

2 Specifications
2.1 Target Microcomputer and Specifications
For any items that are not specifically described here, the standard specifications of the
NET IMPRESS are applied.
Target Microcomputer FH808M07
Microcomputer H8S/2134F
H8S/2612F
User Flash Memory Capacity 128Kbyte
User Flash Memory Address #000000 to #01FFFF
Programming Voltage (Vpp) Not applied.
Default
Vccp (Minimum voltage during
programming)
Object File Format
Intel HEX
Motorola S
Binary
Default Motorola S
Target Interface
UART (Asynchronous communication) Interface
2400/4800/9600/19200/31250/38400/62500/76800/10400bps
□MSBfirst ■LSB first
CSI (Synchronous communication) Interface
62.5Kbps/125Kbps/250Kbps/500Kbps/850Kbps/1.25Mbps
□MSBfirst ■LSB first
Data Transfer Format between
Flash Microcomputer Programmer
and Target System
Binary
Memory status when erased #FF
MCU Clock during programming 2MHz to 20MHz 4MHz to 20MHz
2

3 Copying Write Control Program into Microcomputer
3.1 Overview
With the control module FH808, the write control program (WCP) is sent to the target
microcomputer to run on it before execution of the Device Functions. The microcomputer
executes the programming sequence under this write control program.
Copy the write control program into the DOS area of the control module and save it under a
file name with extension “.BTP” in advance.
Only one file with extension “.BTP” can be placed in the DOS area of the control module.
You cannot place multiple files with extension “BTP” or use the control module without
placing a file with extension “.BTP”.
Write Control Program that
is booted.
DOS Area
Object Program File
WCP File
xxx.BTP
abc.S
Control Module
Target System
NET IMPRESS
3

3.2 Copying the Write Control Program File
From the Utility Assy provided with the control module, select an appropriate write control
program that has conditions matching with the target microcomputer.
To save the file with “.BTP” extension in the DOS area of the control module, follow the
steps below.
(1) Set this control module in a personal computer that has a PCMCIA card slot. Make sure
that the PC card driver has been properly installed in advance. For how to install the
PC card driver, see our Web site at the following URL:
https://www.dts-insight.co.jp/en/index.html
See the Q & A page on the flash microcomputer programmer.
(2) Copy the write control program (xxx. BTP) from the Utility Assy into the DOS area of the
FH808 control module.
4

4 Connecting to the Target System and Connector
4.1 Signal List
The table below lists signal example at the side of the target probe connector when using
the control module FH808.
CPU Signal NET IMPRESS Standard Signal CPU Signal
Vss GND 15 1 GND GND
TVpp1 16 2 TVccd User Vcc
TVpp2 17 3 Vcc
WDT 18 4 TRES
FEW TAUX3
TVpp1c 19 5 /TRES /RES
TAUX4
TVpp2c 20 6 TCK SCK2
Reserved 21 7 Reserved
Reserved 22 8 Reserved
Reserved TAUX 23 9
TAUX2
(TRW)
TBUSY 24 10 /TICS
TI0 25 11
TAUX5
(/TOE)
TVccs 26 12 TMODE MD2
TxD2 TRxD 27 13 TTxD RxD2
Vss GND 28 14 GND Vss
Table 4-1: Target Probe Signal List (FH808M07)
•
•
•
Be sure to connect the signals marked with “ “ to the target system.
The signals in dotted parentheses are also controlled for output. Connect them only when
necessary.
Though the signals listed as “reserved” are not to be used, they are being controlled. Therefore,
be sure not to connect them to a circuit of the target system.
5

4.2 Model Connection to a Target System
(6)
TCK SCK2
(12)
TMODE MD2
(18)
WDT
/TRES
(5) /RES
TTxD RxD2
(13)
(2)
TVccd
TxD2
(27)
TRxD
FWETAUX3 (19)
Vcc
GND (1, 14, 15, 28)
Vss
(10)
/TICS
H8S/2612F
User Target System
AZ410
(Probe)
NET IMPRESS
User Power Supply
The recommended value of pull-up and pull-down resistance is 10KΩ.
6

(1) For the signals defined as shared terminals, multiplexing circuit of these signals must be
provided to the user system.
/TICS signal is asserted only when the NET IMPRESS is performing the Device Functions.
/TICS signal multiplexes the signals connected to these shared terminals.
Multiplexing circuits are not required for a target system where these signals for write
control are defined as the control signals for the flash microcomputer.
Inserting the multiplexing circuit into the user system can produce the same conditions with
a state where the NET IMPRESS is not connected (i.e., the connector is unplugged) while
/TICS signal is being negated (when the Device Functions are not executed).
(2) WDT Signal:
The clock signal defined with the WDT Clock Period [FUNC D 5] is generated from WDT
signal terminal by the NET IMPRESS.
Connect this signal to the user circuit that requires the appropriate clock signal when
programming the flash memory.
(3) TRES Signal:
The NET IMPRESS is provided with /TRES signal in the standard probe, which is an open
collector type output so that it can make wired-or connection in the target system and be
connected to /RESET signal of your microcomputer using the user circuit. /TRES signal
can be used when the target system requires a reset signal of positive logic. TRES signal is
a totem pole output signal.
7
Table of contents
Other DTS INSIGHT Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual