DSPPA MAG2126 User manual

20-Zone Speaker Selector & Line Detector
MAG2126
POWER
MAG2126 20 Zones Speaker Selector & Line Detector
User's Manual
Welcome to use DSPPA public address system. For the better use of this product, please read this instruction carefully
prior to use.
Guangzhou DSPPA Audio Co., Ltd
http://www.dsppatech.com

* * Peripheral Equipment
Caution
To assure the finest performance, please use or operate the product in accordance with corresponding
instructions.
This symbol indicates "forbidden content" This symbol indicates "compulsory content"
■ Please make sure that the
power wire is NOT damaged.
Do NOT unplug the equipment
by pulling the power wire;
otherwise it may cause electric
shock, short circuit or fire.
■ When the equipment is in use, DO NOT block the air
outlet which should be kept clear, in order to avoid
overheat.
■Do NOT store this
equipment in any
place with heavy
dust or vibration, or
where it is extremely
cold or hot.
■ Please do NOT place any heavy article on this
equipment. Please operate
switches, buttons or
external audio source
carefully.
■ Please prevent foreign matters (such as paper,
metal etc.) entering the equipment through the gaps
or opening, in such cases, please cut off the power
supply
immediat
ely.
■ Do NOT attempt to remove any internal component
from the equipment, or
to
modify the equipment in
whatever manner.
■ In case that sound is suddenly off or there is
abnormal odor or smoke, please unplug the
equipment from the power socket to avoid potential
electric shock, fire or other accident. The equipment
should be inspected by professional personnel.
Burning Smell
■ If the equipment is not in use for a long period, please
unplug it from the AC power socket to realize zero
energy consumption.

* * Peripheral Equipment
Contents
1. Product Introduction...................................................................................................................................................... 1
1.1 Description......................................................................................................................................................... 1
1.2 Features..............................................................................................................................................................1
2. Description of Appearance.............................................................................................................................................. 1
2.1 Description of front panel......................................................................................................................................1
2.2 Description of rear panel.......................................................................................................................................2
3. Connection Diagram...................................................................................................................................................... 3
3.1 System connection............................................................................................................................................... 3
4. Operation Instruction..................................................................................................................................................... 3
4.1 Start up...............................................................................................................................................................3
4.2 Introduction to Main Interface............................................................................................................................... 4
4.3 System Settings................................................................................................................................................... 7
Safety Precautions.............................................................................................................................................................9
Matters needing attention................................................................................................................................................. 10
Packing List................................................................................................................................................................... 11
Specification...................................................................................................................................................................11

1
1. Product Introduction
1.1 Description
MAG2126 is a 20-zone speaker line detector.
1.2 Features
Independent detection of speaker line impedance change, open circuit, overload and light load for 20 zones
High-performance industry-level CPU, 32 bit high-speed DSP technology which increases detection speed
and precision in each zone
With touch screen alarm display and beeper alarm for zone fault
Max 2A output current of DC 24V wet contact
Support scheduled detection of load status for each zone, even a zone that is turned off
Support real-time detection of load status of closed zone
With load short circuit protection function, automatic return to normal status after troubleshooting
4.3’ touch screen, easy to control and display working status of all zones
With power-off memory function
Compatible with 100V/70V system
20 channels output and 20 channels of input, support 20 audio sources or 20 zones
Support AC 220V and DC 24V power supply, seamless switch between two modes
2. Description of Appearance
2.1 Description of front panel
POWER
1 2 3
MAG2126 20 Zones Speaker Selector & Line Detector
1. 4.3 inch color touch screen
Users could set up functions on this screen.

2
2. Power Switch
Press “一“ to turn on and “O” to turn off. Note: the power switch only controls the AC supply voltage,
and the DC 24V power supply is not controlled by the switch.
3. Power Indicator
Indicator on when power supply is turned on and off when power supply is turned off.
2.2 Description of rear panel
广州市迪士普音响科技有限公司 Guangzhou DSPPA Audio Co.,Ltd.
COM1
WET CONTACTDC24V/4A
POWERIN FAULT ALARM OUT
INPUT OUTPUT
COM 100V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION!
DRY CONTACT
COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
COM2 GND 24V/2A
GND 24V/4A
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
~220V/50Hz/90W
F1AL250V
AMP11AMP12AMP13AMP14AMP15AMP16AMP17AMP18AMP19AMP20
AMP1AMP2AMP3AMP4AMP5AMP6AMP7AMP8AMP9AMP10
2 3 4 5
1 6 7
1. Power fuse
2. AC220V Power Supply
3. POWREIN: 24V DC power input interface
4. FAULT ALARM OUT: Output interface of dry contact and wet contact (WET CONTACT is 24V/2A
interface), alarm signal output when light load or overload in some zones
5. 20 independent zones
6. INPUT: amplifier power input interface
7. OUTPUT: speaker interface

3
3.Connection Diagram
3.1 System connection
4. Operation Instruction
4.1 Start up
Connect each zone correctly and turn on power switch. You will see the following interface. (If the
20-zone load is not fully connected, an alert will be issued when the boot detects a faulted zone)
Figure 1-1 Start up Interface
MAG2126
Amplifier Input
Speaker
广州市迪士普音响科技有限公司 Guangzhou DSPPA Audio Co.,Ltd.
COM1
WET CONTACTDC24V/4A
POWERIN FAULT ALARM OUT
INPUT OUTPUT
COM 100V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION!
DRY CONTACT
COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
COM2 GND 24V/2A
GND 24V/4A
INPUT OUTPUT
COM 100V COM 100V
INPUT OUTPUT
COM 100V COM 100V
~220V/50Hz/90W
F1AL250V
AMP11AMP12AMP13AMP14AMP15AMP16AMP17AMP18AMP19AMP20
AMP1AMP2AMP3AMP4AMP5AMP6AMP7AMP8AMP9AMP10

4
4.2 Introduction to Main Interface
Figure 2-1
Functions:
1. Zone on/off;
2. Zone status display: four colors to indicate four different status– on, off, light load and overload;
3. Load change rate display: R% = original load/actual load*100% (Original load value: load of first-time
calibration)
Note: the error of scheduled detection, all zone detection and single zone detection for used zone is within 20%;
the error of real-time detection for unused zone is within 10%. Therefore, if the detection data changes when
performing scheduled detection, all zone detection and single zone detection, please manually turn off the zone, so
as to further confirm the detection result through real-time detection. Each time the zone is turned off for real-time
detection, wait for 30 seconds to stabilize the data before reading the test data.
Click to turn to
next interface as
Figure 2-2

5
Figure 2-2
(1) Zone function description
All zone detection: press this button to detect all 20 zones.
Single zone detection: press this button and choose a zone to detect. Note: no other operation could be
done at the same time.
Single zone calibration: press this button and choose a zone to calibrate (only zones that are
successfully connected and load rate is not 100% could be calibrated individually). Note: no other
operation could be done at the same time.
All zone on: press this button to turn on all zones.
Fault Ack: this button will turn red and give alarm when there is light load or overload in some zones.
Press it to stop giving alarm.
Status display: click “ ” to enter the interface as Figure 2-4.
System settings: click “ ” to enter the interface as Figure 3-1.
(2) Zone status description
: normal load, zone off
: normal load, zone on
: load open circuit, zone off
: load open circuit, zone on
: light load, zone off

6
: light load, zone on
: overload, zone off
: overload, zone on
: load short circuit, zone off, zone cannot be turned on
Note: If some zones are not used, please insert a 4P/5.08MM interface with 1.5K/0.25W resistors into the unused
output as shown in Figure 2-3 (this interface with resistor is not allowed to connect the amplifier output), so that
all the zones will be displayed normally.
Figure 2-3
Figure 2-4
Click to view
operation
instruction and
function
introduction.
Impedance threshold setting
button, press Enter to save your
change
Display detection time
interval (h/m/s)

7
Figure 2-5
4.3 System Settings
Figure 3-1
Table of contents
Other DSPPA Recording Equipment manuals