Drainvac CYCLONIK Series User manual

MAN.CYC.AN
PRINTED IN CANADA (02-21)
OWNER’S MANUAL
CYCLONIK SERIES
Cleaning Systems

Central Vacuums
Central Vacuums
The compact series’ models
do not comply with NFPA standards.
IMPORTANT SAFETY INSTRUCTIONS
When using an electronic appliance, basic safety precautions should always be
followed. Read all guidelines before operating the unit.
To reduce risk of fire, electric discharges or injuries :
• Use this vacuum only for its intended use as described in this manual. (Use of
attachments not recommended by the manufacturer may cause fire, electric shock,
injury or damage to system components.)
• Do not allow vacuum to be used as a toy. Close supervision is necessary when this
vacuum is used by or near children.
• Do not leave the unit running without any supervising. Disconnect the unit if it is not
used and before maintenance.
• The Cyclonik series is designed to pick up small quantities of liquids only, up to 16 L
(3.5 imp. gal.). However, models DV1R800 and DF1R630 cannot pick up any liquid.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or
hot ashes.
• Do not pick up any flammable liquids or combustible materials (gasoline, fuel, diesel)
hot debris, waste solvents (paint or other), explosive materials that would cause
harm to the vacuum cleaner.
• Do not vacuum drywall dust or baking flour as it may cause damage to your vacuum.
• Avoid picking up hard or sharp objects to prevent damaging or block the hose and
the plastic pipes.
• Do not put any object into openings. Do not use if an opening is blocked. Keep free
of dust, lint, hair and anything that may reduce airflow/suction. Lack of air flow will
cause the motor to overheat.
• This vacuum cleaner creates suction. Keep hair, face, fingers, all body parts and
loose clothing away from any openings.
• Never operate without dust bag and/or filter in place.
• Never plug in a unit designed to operate with a current of 120V in a 230V outlet and
vice versa.
• If the power cord is damaged, it must be replaced by a special cord available from
the authorized local dealer/distributor.
• Do not use extension cords or outlets with inadequate current carry capacity.
• Never operate this vacuum if it has a damaged cord or plug, if it is not working
properly, or if it has been dropped or damaged. Return to authorized dealers/
distributor for repairs.
• Never handle plug, cord or power units with wet hands.
• Never disconnect plug by pulling cord. To disconnect from the outlet, grasp the plug,
not the cord.
• Connect to a properly grounded outlet only. See grounding instructions.
• Keep cord away from heated surfaces.
• Turn off all controls before unplugging.
• Hoses with electrical connections must not be used if damaged.
By overlooking safety rules, you might risk putting your health in danger and to those
who surround you!
Drainvac disclaims any responsibility should you infringe upon these guidelines.
SAVE THESE INSTRUCTIONS

4 5
INTRODUCTION TABLE OF CONTENTS
We wish to thank you for your trust and congratulate you for having chosen a Drainvac
product. It is a sound investment that will satisfy your vacuuming needs for years to come.
Drainvac’s central vacuum cleaners are manufactured and checked at our factory by our
qualified staff who have been specifically trained to this end. A number of installations
and operating methods must be followed to ensure your system’s maximum performance
and to avoid unnecessary service calls. Please read this manual carefully.
First off, we recommend you to fill out
this form before you start the installation
process. If you have any concerns or
problems you may encounter, please
contact the nearest retailer. The unit’s
profile will be required.
To fill in the Drainvac product registration form, go to
www.drainvac.com/client-support/register-your-drainvac
Model* :
Serial number* :
Retailer name :
Date of purchase:
Date of the last maintenance:
*This information is found on a metal tag located on the left side of the unit.
Metal tag
REGISTRATION
MODEL TYPE .................................................... 6-7
UNIT DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
INSTALLATION
FIRST THINGS FIRST.................................................. 14-15
MOUNTING THE UNIT TO THE WALL .................................... 16-17
CONNECTING THE DUST INLET............................................17
AUDIOPROTEK MUFFLER / AIR OUTLET................................. 18-19
PIPING INSTALLATION
GENERAL NOTES.................................................... 20-21
INSTALLATION DIAGRAM..............................................22-24
EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS .................25-27
ELECTRICAL POWER SUPPLY
PROCEDURE / EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS ...... 28
DIAGRAMS OF AN APPROPRIATE CONNECTION ............................ 29
GROUNDING INSTRUCTIONS............................................. 30
MAINTENANCE PROCEDURES............................ 30
WEEE GUIDELINES .............................................31
TECHNICAL PROBLEMS / SUPPORT................... 32
ANNEX
ANNEX I (CIRC02)
ANNEX II (CIRC03)
ANNEX III (CIRC18)

6 7
INTERNATIONAL (220V - 240V) INTERNATIONAL (220V - 240V)
MODEL TYPE MODEL TYPE
You have purchased one of the following models. Identify the one related to it.
The model number is marked on the label stuck on the left side of the head.
RESIDENTIAL SERIES
NORTH AMERICA (108V - 120V)
COMMERCIAL SERIES
NORTH AMERICA (108V - 120V)
MODELS AIR WATTS H2O CFM DECIBELS AMPS GAL./L SIZE in / cm
DV1R12-CT 700 145 136 62 11.6
10 / 46 15 dia. x 38 /
38 dia. x 95
DV1R15-CT 2 x 355 160 111 70 18
DV1R800 800 138 138 60 14
MODELS AIR WATTS mmH2O m3/h DECIBELS AMPS GAL. / L SIZE in / cm
DF1R11 483 3148 207 66 7
10 / 46 15 dia. x 38 /
38 dia. x 95
DF1R15 2 x 355 4191 198 70 10.8
DF1R630 700 3880 315 58 7
MODELS HP H2O CFM DECIBELS AMPS GAL./L SIZE in / cm
DV1R12-CTTM 2.1 145 136 62 11.6
10 / 46 15 dia. x 38 /
38 dia. x 95
DV1R15-CTTM 3 160 111 70 18
DV1R19-27CT 3.9 181 122 70 22
DV1R20-27CT 3.9 181 122 70 22 12 / 54 15 dia. x 51 /
38 dia. x 130
MODELS HP mmH2O m3/h DECIBELS AMPS GAL. / L SIZE in / cm
DF1R19-CT 3.46 4191 198 70 10.8 10 / 46 15 dia. x 38 /
38 dia. x 95
DF1R20-CT 3.46 4191 198 70 10.8 12 / 54 15 dia. x 51 /
38 dia. x 130

8 9
DV1R12-CT / DV1R12-CTTM* DV1R15-CT / DV1R15-CTTM* / DF1R15
UNIT DESCRIPTION
Exhaust muffler
UNIT DESCRIPTION
Canister
Audioprotek muffler
24V plug
Power cord
Power cord
Canister
24V plug
Exhaust muffler
Audioprotek muffler
Audioprotek muffler
*The DV1R12-CTTM model has an hour meter. *The DV1R15-CTTM model has an hour meter.

10 11
DF1R11DV1R800 / DF1R630
UNIT DESCRIPTION UNIT DESCRIPTION
Exhaust muffler
Canister
24V plug
Power cord Foam filter
Exhaust muffler
Canister
Audioprotek muffler
24V plug
Power cord

12 13
DV1R19-27CT / DF1R19-CT DV1R20-27CT / DF1R20-CT
UNIT DESCRIPTION UNIT DESCRIPTION
Power cord* Power cord*
Canister Canister
24V plug 24V plug
Exhaust muffler Exhaust muffler
Audioprotek muffler Audioprotek muffler
Audioprotek muffler Audioprotek muffler

14 15
12’’ (30cm)
24’’ (60cm)
10’’
(25cm)
51’’ (130cm)
INSTALLATION
- FIRST THINGS FIRST -
REQUIRED TOOLS
Philips Screwdriver
Cutting Pliers Measuring Tape Hole saw 2.25”
(57 mm)
Drill 0.5”
(12.5 m) bit
Mitre box and saw PVC Pipe Cutter
2” (50 mm)
Regular Screwdriver5/16” Socket
Head Screwdriver
or
INSTALLATION
- FIRST THINGS FIRST -
WHERE TO INSTALL THE UNIT
We recommend installing the system on the lowest level of the building to avoid having
to work against gravity. Dust and solids will fall easier than being pulled upwards, this
is why the basement is generally the most ideal location. If there is no basement, the
garage or a storage room will do.
MINIMUM DIMENSIONS AND SPACING
It is important to install the unit in a location where it will be easily
accessible for maintenance and to effectively evacuate dust. The
minimum spacing required is the following:

16 17
INSTALLATION INSTALLATION
Gypsum
Board
Wood
Panel
Wall Stud
• Attach the bracket to the wall with the 5 screws supplied with the head.
If the wall includes wall studs covered with gypsum board, we recommend
installing a wooden panel screwed to the wall studs beforehand for more stability.
Cut the
fastener
1) MOUNTING THE UNIT ON THE WALL
• Undo the fastener securing the wall bracket and base at the
back of the unit with cutting pliers.
Suggested distance from the floor:
50” (125 cm)
• Lift the unit and slide its
support onto the wall bracket.
2) CONNECTING THE
DUST INLET
• Connect the dust inlet onto the unit
securing it with a collar (do not glue).

18 19
INSTALLATION INSTALLATION
3) AUDIOPROTEK MUFFLER
All Cyclonik systems are supplied with Audioproteks,
except for models DV1R800 and DF1R630.
• Instructions on how to assemble the Audioprotek mufflers are included in a leaflet
inside the packaging.
4) AIR OUTLET
An air outlet leading outside the building is mandatory for all Cyclonik systems,
except for models DV1R800 and DF1R630, which you can install an Activac 3 filter.
MUFFLER
• Connect the air outlet to the unit, securing it with a clamp and install the muffler
with a second collar (do not glue).
ACTIVAC 3
• Clamp the 90oshort elbow to the unit
with the supplied collar and insert
the Activac3 filter to the other end
with a second collar (do not glue).
2 motor unit1 motor unit
Installation with a straight pipe.
Straight muffler Straight muffler
Curved muffler
Installation with a 90oelbow.
STEEL MUFFLER
Some units are equipped with a steel muffler to absorb the noise produced
by more powerful systems. Unlike plastic mufflers, this steel muffler must be
installed on the wall.
• You will find the installation method on the sheet provided with the exhaust.
Steel Muffler
This manual suits for next models
12
Table of contents
Other Drainvac Vacuum Cleaner manuals