DR. BENDER EBM 33 F User manual

DR. BENDER
GmbH
Innovative Elektrowerkzeuge
Manual for
drilling motor EBM 33 F
EBM 33 S
230 V
Valid from 01.2019 Art.-Nr. 201296 Subject to alterations
201297
All rights reserved
DR. BENDER
GmbH • D-75382 Althengstett • Tel 07051-9291-0 • Fax 07051-9291-91
Our website address is: http://www.dr-bender.de• eMail: info@dr-bender.de

2
Conformity Declaration
DR.BENDER
GmbH
Innovative Elektrowerkzeuge
EC declaration of conformity (EG-RL 2006/42/EG)
Hereby the nmanufacturer
Dr. Bender GmbH
Industriestrasse 22
75382 Althengstett
declares for the products
EBM 33 F
EBM 33 S
The named product conforms to the following Council Directives on approximation of laws of the EEC
Member States:
-Council Directive for machinery (2006/42/EC)
-Council Directive for Electromagnetic compatibility (EMC) (2004/108/EG)
-Low Voltage Guide Lines (2006/95/EG)
Conformity with the requirements of this Directives is testified by complete adherence to the following stan-
dards:
EN 50144-1
EN 50144-2-1
EN 55014-1
EN 61000-3-2
EN 61000-3-3
EN 55014-2
EN 61029-1
The instructions contained in the operating manual for installation and start up the machine have to be fol-
lowed.
Authorised Person for Documentation:
Min Wei
c/o Dr. Bender GmbH
Industriestrasse 22
75382 Althengstett
Deutschland
DR.BENDER GmbH Althengstett, 30.07.2018
Industriestraße 22
D-75382 Althengstett
Tel. 07051/9291-0, Fax 07051/9291-91
Min Wei, Managing Director
This Declaration does not include Assurance of Product Properties.
The Safety Instructions of the enclosed Product Documentation have to be respected.

3
Contents
Seite
Conformity declaration 2
Contents 3
1.0 Symbol- and Pictograph description 4
1.1 Function description 4
2.0 General instructions 5
2.1 Application 5
2.2 Safety 5
3.0 Transport and storage 6
3.1 Transport 6
3.2 Storage 6
4.0 Main dimensions and technical data 7
4.1 Dimensions EBM 33F / EBM 33S 7
4.2 Technical data 7
4.3 Noise emissions and vibrations [EN 50144] 8
5.0 Commissioning 8
5.1 Changing gear 9
5.2 Safety coupling 9
5.3 Core bits 9
5.4 To change a core bit 9
6.0 Safety instructions 10
7.0 Servicing and care 11
7.1 Daily care 11
7.2 After approx. 150 hours of use 11
7.3 After approx. 250 hours of use 11
7.4 Quarterly 11
8.0 Speed adjustment dependent on the cutting speed 12
9.0 Warranty 13
10.0 General safety instructions 13
11.0 Spare parts list 14
11.1 Stone drilling machine complete EBM 33 F 14
11.2 Stone drilling machine complete EBM 33 S 16
11.3 Motor complete EBM 33 F 18
11.4 Motor complete EBM 33 S 20
11.5 Gear complete 22

4
Warning
The safety instructions set out in this operating manual must be followed at all
costs.
Special designs and versions may differ from the standard models in terms of their technical de-
tails. If any points are unclear, we urgently recommend that you contact DR.BENDER GmbH, indi-
cating the machine type and machine number.
1.0 Symbol- and Pictograph description
This sign tells you rules, if you not pay attention for this your health and the function of
the machine is in danger. You have no warranty if the machine breaks down because
you not looking about this.
1.1 Function description
Air outlets
Air inlets
Nameplate
Drill-spindle
Water connection
Switch on/off
Quick fastener
PQ6
Handle
Handle

5
2.0 General instructions
2.1 Application
The core drills can be used for the purposes outlined by the data on the model plate. If you are using spe-
cial machines, the details in the quotation and order confirmation also apply.
The core drills are supplied as standard in protection class I, only this can guarantee the full high quality
production of the residual current-operated circuit-breaker or PRCD switch.
If you use suitable core bits, you will be able to drill holes in the most diverse material types:
- Concrete (even if it contains thick reinforcement steel)
- Sandstone and limestone
- All building materials for solid walls
- Asphalt floors
Warning
The core drills comply with the regulations issued by the ”Stone and Earth” Profes-
sional Association issued in July 1989. They are machines of category II, which means
that they must be placed on stands and be stable (pursuant to DIN 57100 or VDE
0100), the stand must be equipped with
- a reversing block, and
- a water suction device.
The machine must be connected to the 230 V mains
- direct using a personal safety switch (residual current-operated circuit-breaker or PRCD), or
- using a coded (1h) plug to a safety box (IP 44) with a residual current-operated circuit-breaker.
2.2 Safety
Warning
Before using the machine for the first time, check that the conformity of the
data on the model plate with the mains voltage and frequency. Voltage devia-
tions of ± 5 % and/or voltage deviations of ± 2 % are permissible. Repairs must
only be completed by quality persons who have suitable training and qualifica-
tions.
The following points are to be given special attention:
- the technical data and details of the permitted use of the machine (commissioning, ambient and
operating conditions) which are set out in the catalogue, the operating manual, the model plate
data and other product information,
- the relevant accident prevention regulations
- the correct use of tools
- the use of personal safety equipment

6
3.0 Transport and storage
3.1 Transport
Warning
The core drills are to be checked for signs for transport damage on receipt. Any
damage must be documented in writing.
3.2 Storage
If possible, the storage site should be dry, clean and have a constant temperature. To ensure that the film
of lubricant in the bearings and sealing system is not lost, the motor shaft should be turned through several
revolutions by hand after a lengthy period of storage, for example at monthly intervals. The roller bearings
in the motors should be replaced (or regreased) if the period between delivery and commissioning is over
four years. If the machines are stored in adverse conditions, this period may differ considerably.

7
4.0 Main dimensions and technical data
4.1 Dimensions
4.2 Technical Data
Rated Voltage 230 V
Current consumption 9 A
Power requirement 2200 W
Frequency 50 – 60 Hz
Idling speed 830 / 2200 / 4600 min
-1
Full speed 520 / 1400 / 2900 min
-1
Output rating 1400 W
Torque 27 / 12 / 6 Nm
Drilling diameter 15 – 150 mm
Weight EBM 33F / EBM 33S 5,2 kg
Core bit connection 6-polygonal profile -
Overload coupling torque 12 Nm

8
4.3 Noise emissions and vibrations [EN 50144]
Noise level Noise level Vibration
dB(A) dB m/s
2
88 101 < 2,5
5.0 Commissioning
Check that the mains voltage is identical with the voltage specified on the model plate.
When drilling a hole ensure that you are on a secure surface. Make particularly sure the core bit is not bent
during the drilling process and hold the core drilling machine as rigid as possible. Concentrate hard on the
work since if the core bit suddenly blocks, despite the low setting of the safety slip clutch, high forces may
be generated. If you let go of the core drilling during the drilling process, you may suffer serious injury.
Only used three-core extension cables with a protective conductor and an adequate cross-section. If the
cross-section is too low you may suffer excessive power loss and the motor and cable may overheat. An
extension cable must be secured with an overload switch. Recommended cable cross-sections:
Rated current = 9 A
Cable length m 7.5 15 25 30 45 60
Cable cross-section
mm
2
2.5 2.5 2.5 2.5 2.5 4
When drilling a hole ensure that you have sufficient cooling water. Only use clean tap water, do not use
dirty or waste water. Adjust the supply to the core bit diameter and drive rating of the core drill so that you
do not exceed the rated current.

9
5.1 Changing gear
Warning
Never change gear using force and only do so when the machine is slowing
down or at a standstill.
Move the gear switch handle by approx. 40° to the next higher or lower gear. If necessary (if it is difficult to
engage the gear) turn the drive spindle briefly by hand until the gear engages easily. Never use tools (pli-
ers, hammer, etc.) to change gear since otherwise gear damage will be inevitable.
5.2 Safety coupling
The values set out in the table are theoretical values and may be used to provide a rough guide for gear
changing. Since a whole range of other parameters also plays a major role in adjusting the speed, we can-
not offer any guarantee if the tool is damaged when using the values in the table. Drilling work for which the
speeds are outside the range of the core drill (values printed in italics), should only be completed with ex-
treme care and by trained personnel.
5.3 Core bits
New core drill bits equipped with the hex polygon connector are already available. Adapters for continued
use of classic core drill bits are also available. Therefore existing equipment can still be used.
Only use core bits that are suitable for the type of stone.
You will keep the core drill in good condition if you only use core bits that are concentric and not deformed
ones.
Ensure that the diamond segments have an adequate undercut against the core bit body.
Warning
To use wrong tools or accessories is danger for your life.
5.4 To change a core bit
The hex polygon connection of the drill spindle allows for toolless assembly and disassembly of the core
drill bit. As soon as the drill bit is positioned on the drill spindle, both hands can be used for tightening the
safety nut on the hex polygon connector. No tools needed anytime.

10
6.0 Safety instructions
Important
Only use the core drill under supervision. Disconnect the mains plug and check
that the switch has been turned off,
- if you intend to leave the core drill unsupervised,
- for attachment and disconnection work,
- if the voltage drops (below 200 V),
- for adjustments or for fitting an accessory,
Switch off the machine if it stops for any reason. This will prevent its starting suddenly when it is not under
supervision.
Do not use the tool if
-part of the casing is missing or defective,
- If water drips out of the overflow hole, stop work and have the core drill inspected by an authorised
service contractor.
-Only drill above your head with suitable safety equipment (water collector), RCD and transformer
protection class II.
-Connect dust extraction if required.
- After a fault do not switch on the machine again until the core bit can be turned easily.
- Check the area you wish to drill with a line detector to prevent drilling through electric cables, water
or gas lines, etc.
- the switch, lead or plug connector has suffered damage (conduct a visual inspection every day).
-Cooling water must not be allowed to ingress into the motor or the electrical components when op-
erating the core drill in any position.
Do not expose the tool to rain and use not in humidity or wet environment. Use a good lightning. Do not use
the tool near flammable fluids or gase air mixes.
This manual suits for next models
3
Table of contents
Other DR. BENDER Drill manuals

DR. BENDER
DR. BENDER EBM 33 FNT User manual

DR. BENDER
DR. BENDER EBM 23 User manual

DR. BENDER
DR. BENDER DX 5 L User manual

DR. BENDER
DR. BENDER 201210 User manual

DR. BENDER
DR. BENDER 200940 User manual

DR. BENDER
DR. BENDER EBM 25 User manual

DR. BENDER
DR. BENDER EBM 23 F User manual

DR. BENDER
DR. BENDER 201216 User manual

DR. BENDER
DR. BENDER EBM 33 User manual

DR. BENDER
DR. BENDER 201214 User manual