Dome Sx User manual

Dome®Sx Display
User’s Guide

© 2012 NDS Surgical Imaging. All rights reserved.
Information in this document has been carefully checked for accuracy; however, no
guarantee is given to the correctness of the contents. This document is subject to
change without notice. Go to web site ndssi.com for the latest documentation.
NDSsi provides this information as reference only. Reference to products from other
vendors does not imply any recommendation or endorsement.
This document contains proprietary information protected by copyright. No part of
this manual may be reproduced by any mechanical, electronic, or other means, in
any form, without prior written permission of NDSsi.
NDS Surgical Imaging, NDSsi, the NDSsi logo, Dome, the Dome by NDSsi logo,
Dome S3, Dome S3c, Dome S10, Dome CXtra, RightLight are either registered or
unregistered trademarks of NDS Surgical Imaging. All other trademarks are the
property of their respective owners.
020-0904 Rev02A

About the Display
The Dome® Sx displays are available in 3 and 10 megapixels and
contain a TFT LCD panel. The display’s thin film transistors, in
a transmissive-type display, use an integrated cold cathode
fluorescent tube (CCFT) backlight system.
The display is designed for medical imaging in diagnostic settings and
comes fully tuned with gamma correction that complies with the
DICOM Part 14 Standard. The all-digital design enables the display to
produce the sharp, crisp images critical to softcopy medical viewing.
Unwanted analog display image artifacts are eliminated.
For display classification and use; environmental guidelines; safety
precautions; handling, cleaning and storage tip; and specifications,
see “Technical Information” on page 7.
System Requirements
• Windows 7 (x86 or x64) or Windows XP Service Pack 3 (x86 or x64)
• Intel or AMD multi-core processor
• PCI Express x16 lane slot
• 50 MB hard disk space
•512MBRAM
•CD-ROMdrive
• Power supply, 350 watts or greater

2 | Dome Sx Display
NOTE: DVI-to-DVI and DisplayPort cables ship in the Dome S3 and Dome S3c display packages. DVI and mini USB
cables ship in the Dome S10 display package.
The Dome S10 display, shown here for illustrative purposes. Your display package
may contain a Dome S3, Dome S3c, or Dome S10 unit.
DC power adapter Power cord
DVI cable DisplayPort cable Mini USB cable Quick reference

About the Display | 3
Display Components
Review the following illustrations to identify controls and ports on
the front and back panels of the Dome Sx displays.
The sensor on the front of the Dome S3 and Dome S3c displays allows
you to run an auto-conformance test without using a photometer.
The MQSA (Mammography Quality Standards Act) button (lower
right, beneath display ID) on the Dome S10 display facilitates any
daily, weekly, or annual tests that you have preset via calibration and
monitoring software.
Front sensor on Dome S3/Dome S3c MQSA button on Dome S10

4 | Dome Sx Display
The Dome Sx displays include the following components on
the connector plate:
•Powerinput.
– On Dome S3, drives power to the display via an 8-pin
DIN connector. The power input is 12V ±5% (130 W).
– On Dome S3c and Dome S10, drives power to the display via
a 6-pin DIN connector. The power input is 24V ±5% (150 W).
•USBport.
– Dome S3/Dome S3c uplink B port. Usage to be defined at
a future time.
– Dome S10 uplink mini-B port. Usage assigned for MQSA
button functionality.
• Video input. Drives the data to the display.
– The Dome S3/Dome S3c display offers two video connector
options: a standard DVI connector or a DisplayPort connector.
– The Dome S10 display offers two standard DVI connectors.
• Reset button. Restores the display configuration to default
setting.
• LED lights. Provides information on the status of the display.
Dome S3/Dome S3c
connector plate
Dome S10
connector plate

Installing the Display | 5
Installing the Display
Turn your computer off. Leave the power cord plugged into the
grounded outlet. Use the Dome Sx display with the power
adapter and video cable shipped.
Connecting the Video and Power Cables
IMPORTANT! For the Dome S3 or Dome S3c display only. Install either
the DVI or the DisplayPort video cable, not both.
To connect the cables
1 Plug one end of the video cable into the video port on
the connector plate. Secure the connection.
2 Plug the power cord into the power input port on the
connector plate.
3 Plug the other end of the cable into the video port on your
computer system. Secure the connection.
4 Plug the other end of the power cord into the power supply.
5 Plug the power supply cord(s) into a grounded AC outlet.
6 Turn on the adapter power before you turn on the computer.
Warning
In locations where 240V outlets are used, connect the Dome Sx
display only to a center-tapped, 240V, single-phase supply (for
Canada and the United States only).

6 | Dome Sx Display
Video Cable Installation on the Dome S10 Display
Note the location of the primary input on the Dome S10 display,
shown below, for proper video cable installation. Improper
connection may cause VGA boot messages not to appear on
the display screen.
Primary video signal input on the Dome S10 connector plate

Technical Information | 7
Technical Information
The design of the Dome® Sx digital display takes into account every
known measure to ensure your personal safety. Improper use of
the display can result in electric shock, fire, or damage to the display.
Read all instructions before setting up the display.
Classification
Shock Protection: Class I.
Degree of Protection Against Electric Shock: No applied part.
Degree of Protection Against Harmful Ingress of Water:
Ordinary equipment (IPX0).
Degree of Safety in the Presence of Flammable Anaesthetic
Mixture with Air or with Oxygen or Nitrous Oxide:
Not suitable for use in the presence of a flammable
anaesthetic mixture with air or with oxygen or nitrous oxide.
Mode of Operation: Continuous.
No applied part
Important recycle instruction
HAZARDOUS SUBSTANCE. Lamp(s) inside this product contain
mercury. This product may contain other electronic waste
that can be hazardous if not disposed of properly. Recycle
or dispose in accordance with local, state, or federal laws.
For more information, contact the Telecommunications
Industry Association at WWW.ECYCLINGCENTRAL.COM. For lamp-
specific disposal information, check WWW.LAMPRECYCLE.ORG.
DISPOSAL. Do not use household or municipal waste
collection services for disposal of electrical and electronic
equipment. EU countries require the use of separate
recycling collection services.
ENVIRONMENT-FRIENDLY USE PERIOD. Hazardous
substances are present. The number encircled by the
recycling symbol indicates the safe-use period (in years).
China requires the use of recycling services at the end of
product life.

8 | Dome Sx Display
Symbol explanations
Intended use
The Dome S series offers AMLCD units designed for viewing medical
X-ray images. A Dome Sx display should not be used near patients
and should be kept outside of 1.83 m perimeter and 2.29 m vertical.
Dome S3 and Dome S3c are intended for use in displaying and
viewing medical images for review and analysis by trained medical
practitioners.
Dome S10 is intended for use in displaying and viewing medical
images for review and analysis by trained medical practitioners, or
for use in displaying and viewing radiographs of the breast for review
and analysis by trained medical practitioners.
IMPORTANT: Only the Dome S10 display can be used for review and
analysis in mammography. Do not use the Dome S3 or Dome S3c
display in mammography review and analysis.
Federal law restricts this device to sale by or on the order of
a medical practitioner.
CAUTION. Read the accompanying text carefully, for
proper operation and maintenance of the display
system.
DANGEROUS VOLTAGE. Important precautions about
electric shock. Read the accompanying text carefully, to
prevent damage to display components and to guard
your safety.
DIRECT CURRENT.
BAROMETRIC PRESSURE. Transport and storage
12,000 meters (39,400 feet), maximum in unpressurized
container.
RELATIVE HUMIDITY. Transport and storage 5% to 90%
(noncondensing).
TEMPERATURE. Transport and storage -20° to 60° C.
Table of contents
Other Dome Monitor manuals