DITEC OBBI3BH User manual

OBBI
IP1639EN - rev. 2012-07-31
Installation and
maintenance manual for
swing gates.
(Original instructions)
EN
DITEC S.p.A.
Via Mons. Ban, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314

2
IP1639EN • 2012-07-31
INDEX
All rights reserved
All data and specications have been drawn up and checked with the greatest care. The manufacturer cannot
however take any responsibility for eventual errors, omissions or incomplete data due to technical or illustrative
purposes.
Subject Page
1. General safety precautions 3
2. Declaration of incorporation of partly completed machinery 4
2.1 Machinery Directive 4
3. Technical specications 5
3.1 Operating instructions 5
4. Standard installation 6
4.1 Geared motor references 7
5. Installation 8
5.1 Preliminary checks 8
5.2 Geared motor installation 8
6. Electrical connections 11
6.1 OBBI3BFCH limit switch adjustment 12
7. Ordinary maintenance program 13
8. User instructions 15
8.1 General safety precautions 15
8.2 Manual release instruction 15

3IP1639EN • 2012-07-31
1. GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally competent personnel only.
Installation, electrical connections and adjustments must be performed in accordance with Good Working
Methods and in compliance with applicable regulations.
Before installing the product, carefully read the instructions.
Bad installation could be hazardous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within
reach of children, as these are a potential source of hazard.
Before installing the product, make sure it is in perfect condition.
Do not install the product in an explosive environment and atmosphere: gas or inammable fumes are a serious
hazard risk.
Before installing the motors, make all structural changes relating to safety clearances and protection or segre-
gation of all areas where there is risk of being crushed, cut or dragged, and danger areas in general.
Make sure the existing structure is up to standard in terms of strength and stability.
The motor manufacturer is not responsible for failure to use Good Working Methods in building the frames to
be motorized or for any deformation occurring during use.
The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account:
applicable laws and directives, Good Working Methods, installation premises, system operating logic and the
forces developed by the motorized gate.
The safety devices must protect any areas where the risk exists of being crushed, cut or gragged, or where
there are any other risks generated by the motorized gate.
Apply hazard area notices required by applicable regulations.
Each installation must clearly show the identication details of the motorized gate.
Before making power connections, make sure the plate details correspond to those of the power mains.
Fit an omnipolar disconnection switch with a contact opening gap of at least 3 mm.
Make sure an adequate residual current circuit breaker and overcurrent cutout are tted upstream of the
electrical system.
When necessary, connect the motorized gate to a reliable earth system made in accordance with applicable
safety regulations.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the
electrical parts.
To handle electronic parts, wear earthed antistatic conductive bracelets.
The motor manufacturer declines all responsibility in the event of component parts being tted that are not
compatible with the safe an correct operation.
For repairs or replacements of products only original spare parts must be used.
The installer shall provide all information relating to automatic, manual and emergency operation of the
motorized gate, and provide the user with operating instructions.

4
IP1639EN • 2012-07-31
2. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY
(Directive 2006/42/EC, Annex II-B)
The manufacturer DITEC S.p.A. with headquarters in Via Mons. Ban, 3 - 21042 Caronno Pertusella (VA) -
ITALY declares that the automation system for OBBI swing gates:
- has been constructed to be installed on a manual door to construct a machine pursuant to the Directive
2006/42/EC. The manufacturer of the motorized door shall declare conformity pursuant to the Directive
2006/42/EC (annex II-A), prior to the machine being put into service;
- conforms to applicable essential safety requirements indicated in annex I, chapter 1 of the Directive
2006/42/EC;
- conforms to the Low Voltage Directive 2006/95/EC;
- conforms to the Electromagnetic Compatibility Directive 2004/108/EC;
- technical documentation conforms to Annex VII-B to the Directive 2006/42/EC;
- technical documentation is managed by Renato Calza with ofces in Via Mons. Ban, 3 - 21042 Caronno
Pertusella (VA) - ITALY;
- a copy of technical documentation will be provided to national competent authorities, following a suitably
justied request.
Caronno Pertusella, 30-08-2010 Silvano Angaroni
(Managing Director)
2.1 Machinery Directive
Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the same obliga-
tions as the manufacturer of machinery and as such must:
- prepare the technical le which must contain the documents indicated in Annex V of the Machinery Directive;
(The technical le must be kept and placed at the disposal of competent national authorities for at least
ten years from the date of manufacture of the motorized door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Directive and
deliver it to the customer;
- afx the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the Machinery
Directive.

5IP1639EN • 2012-07-31
3. TECHNICAL DATA
OBBI3BH OBBI3BFCH
Power supply 24 V= 24 V=
Absorption 3 A 3 A
Thrust 1500 N 1500 N
Max run 350 mm 350 mm
Opening time 25 s / 90° 25 s / 90°
Limit switch -Magnetic limit switch
Service class 3 - FREQUENT 3 - FREQUENT
Intermittence S2 = 30 min
S3 = 50%
S2 = 30 min
S3 = 50%
Temperature -20 °C/+55 °C -20 °C/+55 °C
Degree of protection IP54 IP54
Control panel E2HOB E2HOB
Applications
m = leaf width
kg = leaf weight
Recommended dimensions
Limit dimensions
500 kg
400 kg
300 kg
200 kg
100 kg
m12345
3.1 Operating instructions
Service life: 3 (minimum 10÷5 years of working life with 30÷60 cycles a day)
Applications: FREQUENT (For vehicle or pedestrian accesses to town houses or small condominiums with
frequent use).
- Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of
maximum permissible weight). When used with the maximum permissible weight a reduction in the above
mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely indicative
Having been statistically determined under average operating conditions, and are therefore not necessarily
applicable to speci c conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental factors,
all of which may substantially alter the performance characteristics of the automatic entrance or curtail
its working life or parts thereof (including the automatic devices themselves). The installer should adopt
suitable safety conditions for each particular installation.

6
IP1639EN • 2012-07-31
TX - 4x0.5 mm²
TX - 4x0.5 mm²
RX - 4x0.5 mm²
RX - 4x0.5 mm²
4x0.5 mm²
2x1.5 mm²
3x1.5 mm²
1
77
3
2
8
A
65
2x1.5 mm²
2x1.5 mm²
77
4
2x1.5 mm²
4. STANDARD INSTALLATION
Ref. Code Description
1GOL4 Transmitter
2LAMPH Flashing light
3XEL5
GOL4M
Key selector
Codied via radio control keyboard
4 LAB9 Magnetic loop detection device for trafc monitoring
5 OBBI3BH
OBBI3BFCH
Right geared motor
Right geared motor with limit switch
6OBBI3BH
OBBI3BFCH
Left geared motor
Left geared motor with limit switch
7XEL2
LAB4
Photocells
Photocells IP55
8E2HOB Control panel
A Connect the power supply to an approved omnipolar switch with an opening distance
of the contacts of at least 3mm (not supplied).
The connection to the mains must be made via an independent channel, separated
from the connections to command and safety devices.
i
NOTE: the given operating and performance features can only be guaranteed with the use of DITEC
accessories and safety devices.

7IP1639EN • 2012-07-31
4.1. Geared motor references
Ref. Code Description
9Key release
10 Casing
11 Draft tube
12 Tube cover
13 Closing plug
14 Tail bracket
15 Head bracket
16 Cable guide sheat hooking bracket
200
110
995
350
13 12
10
11
916
15
14
60
Ø12
68
62
150
83
26
30
Ø12
Ø8,5

8
IP1639EN • 2012-07-31
5. INSTALLATION
Unless otherwise specied, all measurements are expressed in millimetres (mm).
5.1 Preliminary checks
Check that the structure is sufciently rugged and that the hinge pivots are properly lubricated. Provide an
opening and closing stop.
5.2 Geared motor installation
Check the installation measurements on the basis of the distance between the hinge of the door wing and the
corner of the pillar [C] and of the desired opening angle [D].
The installation measurements indicated in the table allow you to choose the values of [A] and [B] on the basis
of the desired opening angle and in relation to the on site spaces and overall dimensions.
NOTE: The measurements [A] and [B] must be the same, in order to have a regular moviment.
Increasing [A] decreases the coming up speed during opening.
Increasing [B] decreases the coming up speed during closing and improves burglar-proong.
Reducing [B] increases the extent of gate opening.
Measurements [A] and [B] must in any case be compatible with the useful travel of the piston so that; if [A] is
increased, [B] must be decreased and vice versa.
A B C max D max E L
150 150 85 100°
75 910
120 160 95 100°
120 180 115 100°
160 120 55 110°
A
D
E
L
min 120
B
C

9IP1639EN • 2012-07-31
- If the gearmotor opening direction needs to be modied, proceed as shown in the gure (example of motor
transformation with opening direction from right to left).
blue
brown
180°
blue
brown
Fig. 5
1
2
3
4
5
• Loosen the motor fastening screws.
• With the reduction gear rotated, insert the
motor and cap, and insert the cable.
WARNING: the motor must be assembled so
that the cable remains on the side opposite
the release
• Extract the motor and the reducer cap and
unthread the motor cable.
• Insert and x the motor fastening screws.
• Rotate the reduction gear by 180°.

10
IP1639EN • 2012-07-31
- Fix the tail bracket [14], respecting measurements [A] and [B] on the basis of the desired opening angle
[D].
On the tail bracket there are holes that facilitate the assembly operation.
- Fix the piston to the rear bracket [14] with the pin [F] supplied.
- Extend the haulage tube completely [11] to its maximum length, then shorten it by approximately 20
mm.
WARNING: the stops must keep a 10 mm margin of tube stroke, in both the door wing closed and door
wing open positions.
- With the gate completely closed, position the front bracket [15], check it is aligned with the rear bracket
and x it to the gate.
- Fix the piston to the front bracket with the pin [G] supplied. To work correctly, the gearmotors must be
assembled with the motor casing at the top.
- Unblock the gearmotor and check (moving the gate manually) the entire stroke is free of interference.
Slightly lubricate the front and rear articulated joints.
- Assemble the tube cover [12] with the cap [13] and seal, and x it with the screws [H] supplied.
Pay attention to the insertion direction. The slits on the closing cap [13] must be on the lower part in order
to help the water to come out.
- Assemble the casing [10], xing it with the screw [N], paying attention to the positioning of the cable.
12
10
N
H
13
11
16
15
G
F
14
Other manuals for OBBI3BH
2
This manual suits for next models
1
Table of contents
Other DITEC Gate Opener manuals

DITEC
DITEC Entrematic FACIL3H User manual

DITEC
DITEC OBBI3BH-E2H User manual

DITEC
DITEC LUXO3BH E2H User manual

DITEC
DITEC QIK7EH-73R User manual

DITEC
DITEC COM502ES User manual

DITEC
DITEC FACIL3EH E2H User manual

DITEC
DITEC entrematic TRAFFIC C User guide

DITEC
DITEC E2 User manual

DITEC
DITEC ENTREMATIC SMART RESET User guide

DITEC
DITEC PAS024AMR User manual