m-Dimension D4006 User manual

User’s Guide
Dimensions 4000 Series
Control System
Topics at a Glance
Installation ...........See Installation Guide
Quick Start Configuration...................10
User Interface ....................................7
Initial Setup......................................18
Scheduling .......................................62
Scene Recording ...............................53
Detailed Operation ............................44
System Layout Charts .......................68

Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 2
OPERATION SETUP QUICK START OVERVIEWCONFIGURATION
Table of Contents
Table of Contents...........................................2
Warnings.......................................................4
Overview .......................................................5
Installation Recommendations.........................6
Getting around the Interface...........................7
Quick Start Configuration................................10
D4104, D4106, D4206 ...........................11
D4006 ..................................................13
D4200 ..................................................14
Power Up Initialization....................................16
Setup ............................................................18
Accessing the Configuration Menus.........19
Network Settings...................................20
The Patch.............................................23
Zone to Channel Patch ..........................24
Dimmer to Circuit Patch.........................27
Configuring Dimmers.............................28
Devices with Dimmers Only (D4006).......33
Miscellaneous Settings Menu..................35
Personalities .........................................40
Connecting Entrance Stations.................42
Operation ......................................................44
Overview of Unit Controls ......................44
Configure the Clock...........................52
Recording a Scene ................................53
Changing the MAX and OFF ...................55
Zone Labels: Naming a Scene or Zone....55
Preventing Changes - LOCKS .................58
Scheduled Events..................................62
Viewing Scheduled Events .....................64
Sequencer ............................................64
System Layout Charts.....................................68
Latitude & Longitude Chart .............................74

Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 4
OPERATION SETUP QUICK START OVERVIEWCONFIGURATION
Warnings
1: To be installed and/or used in accordance with appropriate
electrical codes and regulations.
2: To be installed by a qualified Electrician.
3: DO NOT CONNECT line voltage wires to low voltage
terminals.
4: For longest lamp life, most lamp manufacturers recommend
their fluorescent lamps should be operated at full
brightness for a minimum or 100 hours before dimming is
permitted.
5: For best results, lamp brands and types should not be
intermixed on a circuit
6: Disconnect power when servicing the dimmer, fixture or
when changing lamps.
7: All devices in the D4000 system are rated for Indoor use
only.
8: TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT
MAIN CIRCUIT BREAKER OR FUSE AND TEST THAT THE
POWER IS OFF BEFORE WIRING!
9: Test all circuits for any fault before connecting to this
device. Damage to this device due to any fault at the load
or line side is not covered by this products warranty.
10: Know the connected load type
11: DO NOT connect load types for which the device is not
rated

Page 5
Overview
This guide is split into several sections:
•Overview - Overview of manual, key topics, and device
navigation
•Quick Start - Critical steps for getting up and running
quickly.
•Setup - In-depth topics required for proper initial setup
•Operation - How to operate your device and the features of
the user interface
•Configuration - Detailed configuration information
Accompanying this guide should be an installation guide covering
all the connections and other requirements of proper installation.
Common Topics
•How to operate the device, see page 44.
•Power Up Initialization, see page 16.
•How to configure a dimmer for a fluorescent (or any other
load type,) see page 28.
•How to set the starting network channel, see page 25.
•How to record a scene, see page 49.
•How to set the date and time, see page 52.
•How to prevent changes to the device, see page 58.
•How to trigger a scene at a specific time of day see page
62.

Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 6
OPERATION SETUP QUICK START OVERVIEWCONFIGURATION
Installation Recommendations
For best results using the Dimension 4000 Architectural Lighting
Controllers, follow these recommendations:
1: Plan the system before beginning the installation:
• Device location and primary purpose
• Determine which controllers are controlling which
dimmers
• Determine location and function of remote stations
• Consider power supply, wire size, run length, load
requirements
• Consider any regularly scheduled events.
2: Follow the installation instructions covering physical
installation, connections and wring of your device
3: Use the information in this “setup” section of this guide for
initial setup, and the “configuration” section for regular
programming.
4: When configuring a system with multiple devices it’s helpful
to connect them one at a time so that any problems are
isolated as they arise. For example:
• First install & configure master stations,
• Confirm that the master station is working correctly,
• Install first entry station (or device), configure it, and
confirm that it’s working correctly
• Repeat until all device are installed

Page 7
Getting around the Interface
A full discussion of how to operate your device is covered in the
section titled “Operation” on page 44. We recommend that you
review this information in it’s entirety. Contained in this section is
a only a brief overview to the topic.
Figure 15 - D4200 Buttons
Controls
With the cover closed, you can access the first eight SCENE
buttons and the MAX and OFF buttons.
1 9 2 10 311 412 513 614 15 16
M
as
t
e
r
M
as
t
e
r
P
a
g
e
P
a
g
e
Z
on
es
Z
on
es
C
l
ea
r
C
l
ea
r
M
e
nu
M
e
nu
C
a
n
ce
l
C
a
n
ce
l
S
e
l
ec
t
S
e
l
ec
t
S
ave
S
ave
2-Line, 16-Character LCD
IR Receiver
Scene
Programming or
Recall
Master
Dim/Bright
All Off
Zone
Dim/Bright
78
Zone
Information
Display
All Zones to
Maximum Brightness
Change Zone
Clear
Select Option and Save
Menu and
Cancel Button
Previous Field or
Change Scene Blank
Shortcut
Previous/Next
Menu Option Next Field or
Change Scene Bank
Shortcut
24567813 90
MAX. OFF
Off Button
Max Button
Scene Button

Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 8
OPERATION SETUP QUICK START OVERVIEWCONFIGURATION
Figure 14 - Scene, MAX and OFF button Locations
•SCENES 1-8. Selects a new Scene, and causes a pre
programmed set of lighting levels to fade in while the
previously selected Scene fades out.
•MAX. By default raises all zones to full.
•OFF. By default, raises all zones to zero output.
With the cover open, you can also access the LCD display, the
Master Up and Down buttons, the individual Zone Up
and Down buttons, the Zone identification and status
buttons, the Zone level indicators, and the programming/
navigation buttons.
Navigating Menus
To navigate the menus, use the programming/navigation
buttons:
Figure 11 - Programming Buttons
•Left and Right . Moves the cursor back and
forth, or to the previous or next item.
•Up and Down . Scrolls through menus and
submenus; changes selected values.
•Select/Save. Selects a value to be modified; saves the
modified value.
•Menu/Cancel. Enters menu mode; exits submenus; exits
menu mode.
•Clear. Clears or returns a selected value to zero.
•Page Zones. Alternates the Zone numbers between 1-8
and 9-16, 17-24 and 25-32. The LCD will indicate which
Page you are currently in. P1 refers to Zones 1-8, P2
Select
Save
Menu
Cancel Clear Page
Zones

Page 9
indicates Zone 9-16, P3 indicates Zone 17-24 and P4
indicates to Zones 25-32 are active.
Breakfast P1
S01 TUE 04:29p LE
Page Number - P1 = Zones 1-8
Days of week
Scene #
Indicates Schedule is active
P2 = Zones 9-16
Scene Name
Indicates Station is Locked
P3 = Zones 17-24
P4 = Zones 25-32
Th
e
Z
one num
b
er
LED’
s
d
o no
t
li
g
ht
up on
P3 or P4

Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 10
OPERATION SETUP QUICK START OVERVIEWCONFIGURATION
Quick Start Configuration
This section outlines only the steps required to properly setup
and begin use of your product. A complete review of all
information contained in this guide will help you get the most out
of your system.
Each model has a slightly different feature set so the application
of each step may vary slightly.
Table 1: Find your Product
4104 or 4106 4200
Quick Start on page 11
Part numbers: D4104-***
D4106-***
Control Channels: 4
Local Dimmers: 4
Can control net device: NO
Quick Start on page 14
Part number: D4200-***
Control Channels: 32
Local Dimmers: 0
Can control net device: Yes
4206 4006
Quick Start on page 11
Part numbers: D4206-***
Control Channels: 32
Local Dimmers: 6
Can control net device: Yes
Quick Start on page 11
Part numbers: D4206-***
Control Channels: 32
Local Dimmers: 6
Can control net device: n/a

Page 11
Devices with Channel Control & Dimmers
(D4104, D4106, D4206)
Setting up units with control and dimmers require a few basic
steps which when followed will ensure success of your lighting
control system:
Step 1: Confirm all connections have been completed and load
circuits are without fault.
Step 2: Confirm network is terminated correctly, reference
installation guide for additional information.
Step 3: Complete all “System Layout Charts” on page 68 to
confirm a clear understanding of all system and
configuration requirements.
Step 4: Review “Navigating the Menus” on page 49
Step 5: Power up unit
Step 6: Perform “Power Up Initialization” on page 16 (or
review “Setting the Network ID” on page 20)
Step 7: For load types that are not incandescent, adjust
dimmer load types appropriate. See “Configuring
Dimmers” on page 28
Step 8: If there is more than one master station on the
network, set the starting channel address for this
group of dimmers. Each controller should address it’s
own unique range of channels. See “To Assign Zones,
consecutively, from a Starting Channel Number:” on
page 25.
Step 9: Repeat above steps 4-7 for all other devices on the
network. This is especially critical for other D4006
remote dimmers which will be controlled by this
Master.
Step 10: Push the MAX button
•CONFIRM that all loads of this device and
any remote dimmer go to full. If they DO,
CONGRATULATIONS! You have made it a
long ways towards a successful
installation. If they DO NOT go to full,
please reference the troubleshooting
Other manuals for D4006
1
This manual suits for next models
4
Table of contents