DentalEZ Ramvac User manual

INSTALLATION
MANUAL
VACUUM TANK

i
TABLE OF CONTENTS
SECTION I - SPECIFICATIONS
Tanks .................................................................................................................................................. 1
Tanks/Vacuums Stacked..................................................................................................................... 3
SECTION II - INSTALLATION
Aeras 15-Gallon/30-GallonTank Setup ............................................................................................... 5
Aeras InfiniTank Setup........................................................................................................................ 6
Aeras InfiniTank High-flow Setup........................................................................................................ 7
Cylindrical Tank Setup ........................................................................................................................ 8
SECTION III - AERAS CONTROL
Connections.......................................................................................................................................10
InfiniTank Switch ................................................................................................................................11
SECTION IV - PLUMBING
Drain and Waste Details ................................................................................................................... 12
Drain Check Valve Installation .......................................................................................................... 13
Vacuum Check Valve Installation ...................................................................................................... 13
Tank Inlet Manifold for Multiple Tanks ............................................................................................... 14
Facility Vacuum Line from Operatories ............................................................................................. 14
Tank to Vacuum Power Unit Line ...................................................................................................... 14
SECTION V - AUTOWASH
How the System Works..................................................................................................................... 15
System Schematic ............................................................................................................................ 15
SECTION VI - ACCESSORIES
Tank Vacuum Platform...................................................................................................................... 16
Tank 12" Height Extender ................................................................................................................. 16
Tank Suspension Hooks ................................................................................................................... 17
LIMITED WARRANTY.......................................................................................................................... 19

ii
VACUUM TANK INSTALLATION MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-006A
NOTES:

1
TANKS
SECTION I - SPECIFICATIONS
15-GALLON TANK 30-GALLON TANK
Typical No. of Treatment Rooms† 1-6 7-12
Nominal Width (in) 29" 29"
Nominal Depth (in) 19" 19"
Nominal Height (in) 24" 36"
Floor to Drain Centerline (in) 8" 8"
†This assumes one chair per person. For bays, let“Rooms”equal chairs.
3
2
1
30-GALLON TANK
4
15-GALLON TANK
1
5-GALLON TANK
3
2
1
4
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
1
2
3
4

2
VACUUM TANK INSTALLATION MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-006A
TANKS (CONTINUED)
SECTION I - SPECIFICATIONS
3
1
4
3
1
2
INFINITANK 50-GALLON CYLINDRICAL TANK
2
5
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories* (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit** (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Connects to Aeras control INFINITANK SOLENOID (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
*Tank inlet for 50-gallon tank is 3".
**Tank outlet for 50-gallon tank is 3".
1
2
3
4
5
INFINITANK 50-GALLON CYLINDRICAL TANK
Typical No. of Treatment Rooms† 1-20 13-20
Nominal Width (in) 29" 26"
Nominal Depth (in) 21" 26"
Nominal Height (in) 38" 62"
Floor to Drain Centerline (in) 8" 5"
†This assumes one chair per person. For bays, let "Rooms" equal chairs.

3
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Platform (optional)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
1
2
3
4
3
3
15-GALLON TANK
WITH RV4-12
15-GALLON TANK
WITH RV5-2, RV7-2 OR RV10-2
Typical No. of Treatment Rooms† 1-6 1-6
Nominal Width (in) 29" 33"
Nominal Depth (in) 19" 21"/22" (RV10-2)
Nominal Height (in) 48" 59"
Floor to Drain Centerline (in) 8" 8"
†This assumes one chair per person. For bays, let "Rooms" equal chairs.
TANKS/VACUUMS STACKED
15-GALLON TANK WITH RV4-12 15-GALLON TANK WITH RV5-2, RV7-2 OR RV10-2
1
1
2
2
4
SECTION I - SPECIFICATIONS
5
5
5

4
VACUUM TANK INSTALLATION MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-006A
4
3
1
TANKS/VACUUMS STACKED (CONTINUED)
30-GALLON TANK
WITH RV5-2, RV7-2, OR RV10-2
INFINITANK
WITH RV5-2, RV7-2, OR RV10-2
Typical No. of Treatment Rooms† 7-12 1-20
Nominal Width (in) 33" 33"
Nominal Depth (in) 21"/ 22" (RV10-2) 21"/22" (RV10-2)
Nominal Height (in) 71" 71"
Floor to Drain Centerline (in) 8" 8"
†This assumes one chair per person. For bays, let "Rooms" equal chairs.
30-GALLON TANK WITH RV5-2, RV7-2 OR RV10-2
2
INFINITANK WITH RV5-2, RV7-2 OR RV10-2
1
3
2
44
SECTION I - SPECIFICATIONS
6
5
5
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Platform (optional)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
Connects to Aeras control INFINITANK SOLENOID (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
1
2
3
4
5
6

5
DUAL TANK
MULTIPLE TANK MULTIPLE VACUUM
AERAS 15-GALLON/30-GALLON TANK SETUP
1
3b
3a
2
4
3a
3b
1
42
2
1
4
3b
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit mounted tank (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Connects to vacuum unit located remotely (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Vacuum check valve (see SECTION IV - PLUMBING - VACUUM CHECK VALVE INSTALLATION)
Suspension Hooks - Remove tank legs. Use leg bolts to attach and suspend tank from ceiling with chain or cable (customer
supplied).
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
1
2
3a
3b
4
5
SECTION II - INSTALLATION
SUSPENDED TANK
25
1
3b
6
6
6
6
6

6
VACUUM TANK INSTALLATION MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-006A
AERAS INFINITANK SETUP
SECTION II - INSTALLATION
3
2
4
5
AERAS INFINITANK
1
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
Connects to Aeras control INFINITANK SOLENOID (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
1
2
3
4
5

7
AERAS INFINITANK HIGH-FLOW SETUP
AUTOWASH NOZZLE
(ONLY USED WITH
OPTIONAL AUTOWASH
FEATURE)
3
2
REMOVE INFINITANK DRAIN CHECK VALVE
AND INSTALL PROVIDED COUPLER TO
CONNECT DRAIN PLUMBING
(LEAVE SERVICE SLIDE VALVE IN PLACE)
INSTALL INFINITANK DRAIN CHECK VALVE DOWNSTREAM
FROM 50-GALLON TANK DRAIN CHECK VALVE
FLOW
FLOW
TWO CHECK
VALVES INSTALLED
SECTION II - INSTALLATION
1
5
NOTE: Shipped with a parts bag labeled“Parts for Optional High-flow InfiniTank”containing a coupler and a plug.
See below for proper assembly.
Connects to waste piping (see SECTION IV - PLUMBING - DRAIN AND WASTE DETAILS)
Connects to operatories* (see SECTION IV - PLUMBING - FACILITY VACUUM LINE FROM OPERATORIES)
Connects to vacuum unit** (see SECTION IV - PLUMBING - TANK TO VACUUM POWER UNIT LINE)
Connects to Aeras control INFINITANK SOLENOID (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
Connects to Aeras control TANK FLOAT (opt.) connector (see SECTION III - AERAS CONTROL - CONNECTIONS)
*Tank inlet for 50-gallon tank is 3".
**Tank outlet for 50-gallon tank is 3". Tank outlet for InfiniTank is 2".
a. Connect the two tank outlets together as shown.
b. See SECTION II - INSTALLATION - CYLINDRICAL TANK SETUP - MULTIPLE VACUUM for connection.
1
2
3
4
5
4
INFINITANK INLET:
INSTALL PROVIDED
PVC PLUG