PMT Panel Mount Power
Supply
5 V 35 W 1
Phase
/ PMT-5V35W1A
□
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (February 2022, Rev. 08)
Reliability Data
MTBF > 700,000 hrs. as per Telcordia SR-332
I/P: 100 Vac, O/P: 100% Load, Ta: 35°C)
Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C)
Safety Standards / Directives
UL/cUL recognized
CB scheme
BIS
UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)
UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)
IEC 60950-1, IEC 62368-1
IS 13152-1
CE In conformance with EMC Directive 2014/30/EU and Low
Voltage Directive 2014/35/EU
UKCA
In conformance with Electromagnetic Compatibility Regulations
2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation Input to Output 3.0 KVac
Input to Ground 1.5 KVac
Output to Ground 0.5 KVac
EMC
CISPR 22, EN/BS EN 55032, FCC Title 47: Class B
Immunity to EN/BS EN 55024
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80 MHz-1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
2 kV
Surge IEC 61000-4-5 Level 3 Criteria A1)
Common Mode2): 2 kV
Differential Mode3): 1 kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150 kHz-80 MHz, 10 Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1)
10 A / Meter
Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20 ms); Self Recoverable
Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 200 A Criteria A1)
Common Mode2): 2 kV
Differential Mode3): 1 kV
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)