Delixi EKW-5A-B User manual

EKW-5A-B Foot Switch
User Manual
□ Please carefully read this User Manual before
installing and operating the product, and keep this
manual properly for future reference

LX10 Series Travel Switch
User Manual
Safety Notice
Please carefully read this instruction before the installation, operation, run, maintenance, and inspection,
and follow the contents of the instruction to properly install and operate this product.
Danger:
⚫Do not operate the travel switch with wet hands;
⚫It is forbiddent to touch the live parts during operation;
⚫Mark sure that the product is deenergized during the maintenance and service;
Caution:
⚫The installation, maintenance and service shall be performed by the qualified professional;
⚫Various characteristics of product have been set in factory and cannot be disassembled or adjusted
without permission during operation;
⚫Please confirm that the rated voltage, rated current, frequency and characteristics of the product meet
the operating requirements before use;
⚫If found damage or abnormal sound when unpacking, please stop the machine immediately and
contact the supplier;
⚫When scrapping the product, please dispose the product waste properly. Thanks for your cooperation.

About LX10 Series Travel Switch
● Panel Introduction
Legends:
1 company logo;
2 Basic parameters:
AC-15 Ue: 380V Ie:1.9А;
DC-13 Ue: 220V Ie:1.1А;
3 Standard: GB/T14048.5;
4 Hit head structure;
5 Product model;
6 3C mark;
7 Protection grade: IP62 (after installation);
8 Resistive current in free air is Ith=10A.
●Hit head structure form and basic data
Table Hit head structure form and basic data
Model
Hit head structure form
Operating arm pushing speed m/min
LX
Ruler rod operating arm
150
LX
Fork-shaped operating arm with roller
100
LX
Lever-shaped operating arm with a balance hammer
25

Normal Operation, Installation and Transport Conditions
●Normal operation and installation conditions
(1) The ambient air temperature is not higher than +40℃, and is not below -5℃; the average value within 24
hours does not exceed +35℃;
(2) The altitude of the installation site does not exceed 2000m;
(3) The relative humidity of the atmosphere does not exceed 50% at the maximum ambient temperature of +40℃,
and a higher relative humidity is allowed at lower temperatures, such as 90% at 20℃. Special measures shall be
taken for condensation occasionally generated due to temperature changes.
(4) The product can be installed in any installation angle;
(5) Installed in a place where there is shock vibration for obvious shaking without rain or snow erosion;
(6) Pollution level: Level 3;
(7) Installation category: Class II;
(8) Rated impulse withstand voltage: 6kV;
(9) Protection grade: IP62 after installation.
●Normal Storage and Transport Conditions
(1) Temperature: -25℃~+55℃;
(2) Relative humidity: ≤90%;
(3) During transport, please gently handle the product, do not upside the product down, and prevent harsh
collision;
Install product
● The outline dimensions and installation dimensions are shown below:

LX10-11, 12
LX10-21, 22

LX10-31, 32
●Debugging and operation
(1) Check whether the technical parameters on the product nameplate meet the working requirements.
(2) Fix and tighten the product with screws. (It is recommended that spring washers and flat gaskets are used).
(3) After installation, please carefully check the Hit headfor blockage when being pushed and whether the switch
core works within the specified range; if found any fault, check and re-install it, and then connect the lead wire.
(4) The lead wire selects the one or two copper wires with sectional area of 0.75mm2~1.5mm2.
(5) When connecting the lead wire, it can be combined into the OFF/OF state according to the wiring schematic
diagram shown in Fig. 1 and Fig. 2. Carefully distinguish the normally open and normally closed contact terminal
set of the core wiring terminal to prevent reverse connection or wrong connection.
Fig. 1 ON/OFF indicator formed by each circuit of
LX
type travel switch

Fig. 2 ON/OFF indicator formed by each circuit of LX
type travel switch
Maintenance and Service
⚫The installation, maintenance and service shall be performed by the qualified professional;
⚫The product shall be de-energized during the maintenance and servcie;
⚫The mainteance and service is conducted once a year under normal operating conditions, and the mainteance
contents are listed in table below. Table Maintenanc and Service
Item
Contents
Appearance
No dust, no condensation, clean if necessary
No damage
No color changes on the shell and connecting terminal
Terminal block connections
Tighten it according to the torque 1.2N·m without any
looseness
Switch making and breaking reliabilty
Check whether the swtich is connected or disconnected
before and after action.
Company Commitment
Under the condition that users follow the use and storage conditions and the product are well sealed, within 36
months from the production date, our company will provide repair and replacement service free of charge for any
damage or abnormal operation due to poor manufacture quality. A paid repair will be provided if the warranty
period expires. For any damage due to one of the following situations, a paid repair will be given even if within
the warranty period:

(1) Improper operation, maintenance, or storage;
(2) Modified without permission or improper repair;
(3) Damage due to falling off or caused during installation after purchase;
(4) Force majeure such as earthquakes, fires, lightning strikes, abnormal voltages, and secondary disasters;
If you have any question, please contact the dealer or our company’s customer service department.
Customer service hotline:400-826-8008
Certificate
DELIXI ELECTRIC LTD
Name: Travel switch
Model: LX10 Series
This product passes the inspection and is allowed to be
shipped
Standard: GB/T 14048.5
Inspector: Check 05
Production date: See label on inner box
Manufacturer: Zhejiang Delixi Electrical Co., Ltd.
Address: Delixi High-Tech Industrial Park, Liushi Town, Yueqing City, Zhejiang P/C: 325604
Tel: (86-577) 61778888
Fax: (86-577) 61778000
Customer Service Hotline: 400-826-8008
www.delixi-electric.com
The first edition of this user manual was issued in May 2018
Other Delixi Switch manuals






















