Daikin DCM601A51 Quick start guide

Commissioning Manual
intelligent Touch Manager
Model
DCM601A51
MONITOR
CPU ALIVE
SLAVE
MASTER
BACKUP
LAN SW
SERVICE LAN
FRONT BACK
DⅢMASTER
ON
OFF RESET
LAN LINK
DⅢMONITOR

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
1
Contents
System Overview............................................................................4
1. About the iTM (intelligent Touch Manager)......................................................4
1-1 System Configuration ......................................................................................................... 4
2. Engineering ........................................................................................................5
2-1 Engineering Workflow......................................................................................................... 5
2-2 Logging into Service Mode ................................................................................................. 7
Names and Functions ....................................................................9
3. Detailed Screen Description .............................................................................9
3-1 Setup Screen Structure ...................................................................................................... 9
3-2 Service Settings Tab ......................................................................................................... 10
3-3 System Settings Tab ......................................................................................................... 12
Basic Functions............................................................................13
4. Service Settings ...............................................................................................13
4-1 Mgmt. Point Data Regist ................................................................................................... 13
•Registering a management point with the iTM unit....................................................... 14
•Detailed Mgmt. Point Attributes screen and button descriptions................................... 21
•Registering management points using a CSV file......................................................... 33
4-2 Other Setting..................................................................................................................... 38
4-3 DIII-NET Engineering ....................................................................................................... 39
4-4 Time Zone......................................................................................................................... 41
4-5 Changeover Option........................................................................................................... 41
4-6 History Mgmt. (Delete)...................................................................................................... 43
4-7 Pre-engineering ................................................................................................................ 44
•Displaying the main screen........................................................................................... 46
•Scenario 1: Installation to new property........................................................................ 48
•Scenario 2: Maintenance of existing property
(When carrying out pre-engineering using the current setting).................. 52
•Scenario 3: Restore with existing property’s backup data............................................. 54
•Scenario 4: Implementation of new functions due to existing property’s upgrade ........ 55
Contents

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
2
4-8 Upgrade ............................................................................................................................ 55
4-9 Backup.............................................................................................................................. 56
4-10 Installation...................................................................................................................... 58
4-11 Contact Info.................................................................................................................... 60
4-12 Setting outdoor unit........................................................................................................ 62
•Precautions when using DIII-NET EXPANDER ADAPTER........................................... 63
•Table of types ................................................................................................................ 63
4-13 Leakage Check .............................................................................................................. 69
•Preparations.................................................................................................................. 70
•Registering indoor units ................................................................................................ 70
•Running Leakage Check by Schedule Control ............................................................. 72
•Copying a schedule program ........................................................................................ 74
•Starting Leakage Check by manual operation .............................................................. 75
•Stopping Leakage Check by manual operation ............................................................ 76
•Outputting the Leakage Check results to a CSV file..................................................... 77
•Conflict with other controls............................................................................................ 79
•Failure mode ................................................................................................................. 81
Optional Functions.......................................................................84
5. Service Settings ...............................................................................................84
5-1 Activation .......................................................................................................................... 84
•Acquiring the Activation key.......................................................................................... 84
•Entering the Activation key............................................................................................ 84
5-2 Dealer Option Setup ......................................................................................................... 86
Operating Optional Functions.....................................................87
6. System Settings ...............................................................................................87
6-1 Network ............................................................................................................................ 87
6-2 Web Remote Management............................................................................................... 90
•Connecting the PC and iTM.......................................................................................... 91
•Checking the Web browser and Flash Player versions ................................................. 92
•Setting up the IP address (Windows XP Professional) ................................................. 93
•Setting up the IP address (Windows Vista Business) ................................................... 97
•Setting up the IP address (Windows 7 Professional) .................................................. 101
•Precautions when using Internet Explorer on Windows Vista and Windows 7............ 104
•Network Connection Check ........................................................................................ 105

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
3
•Logging into Service Mode via Web Remote Management........................................ 108
iTM integrator Explanation .......................................................109
7. iTM integrator .................................................................................................109
7-1 Basic Setup..................................................................................................................... 109
7-2 iTM integrator Service Settings ...................................................................................... 114
•Service Settings Tab (Menu List Screen).................................................................... 115
•Controller Access Setup ............................................................................................. 116
Appendix .....................................................................................120
8. Useful Information .........................................................................................120
8-1 Troubleshooting .............................................................................................................. 120
9. Hardware Specifications ...............................................................................122
9-1 iTM Hardware Specification............................................................................................ 122

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
4
1. About the iTM (intelligent Touch Manager)
1-1 System Conguration
iTM
iTM
plus adaptor
iTM
plus adaptor
iTM
plus adaptor
iTM
plus adaptor
iTM
plus adaptor
iTM
plus adaptor
USB memory
Di/Pi port
RS485
(Expansion adapter port)
Di/Pi port
Up to 7
D3net port
Up to 64 groups
LAN port
USB port
D3net
ROUTER
Web Remote Management
Web Remote Management
Port 1~4:
Port 1:
Port 2~4:
HUB/SWITCH/ROUTER/....
Emergency Stop signal input
Power meter pulse input
Input signal (contact) such as
power outage signal
Emergency Stop signal input
Power meter pulse input
Input signal (contact) such as
power outage signal
Intranet/Internet
Web Remote Management possible from network-
connected PC
Simultaneous login of max. 4 managers and 16
users supported.
System Overview

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
5
2. Engineering
2-1 Engineering Workow
Various engineering works are necessary for using the iTM.
Engineering works can be roughly divided into those carried out at the ofce in advance and those
carried out on site after installation.
The following diagram shows the engineering workow.
New installation (Without using the pre-engineering tool)
At the ofce See:
Prepare various information.
Check the equipment to connect to DIII-NET.
Allocate the Group Address.
Acquire the upgrade data. 4-8 Upgrade
Acquiring the Activation key
* When necessary
5-1 Activation
Acquiring the Activation key
At the site
Install the iTM. Installation Manual (EM11A016)
Install the upgrade data. 4-10 Installation
Make basic settings.
(Boot sequence) Installation Manual (EM11A016)
Set up “Main” and “Sub”. 4-3 DIII-NET Engineering
Activate optional maker functions.
Enable dealer options.
* When necessary
5-1 Activation
Entering the Activation key
5-2 Dealer Option Setup
Register management points and Layout View.
(Load from CSV or register manually) 4-1 Mgmt. Point Data Regist

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
6
New installation (By using the pre-engineering tool)
At the ofce See:
Prepare various information.
Check the equipment to connect to DIII-NET.
Allocate the Group Address.
Acquire the upgrade data. 4-8 Upgrade
Back up the iTM data.
*In the case of maintenance (When pre-engineering by
using the current settings)
4-9 Backup
Set up management points.
(Pre-engineering tool, spreadsheet such as Microsoft
Excel)
4-7 Pre-engineering
Create the Layout View.
(Layout View creation tool)
* When necessary
Commissioning Manual Supplementary
Volume
Layout View Creation Tool (EM11A024)
Acquiring the Activation key
* When necessary
5-1 Activation
Acquiring the Activation key
At the site
Install the iTM. Installation Manual (EM11A016)
Install the upgrade data. 4-10 Installation
Make basic settings.
(Boot sequence) Installation Manual (EM11A016)
Set up “Main” and “Sub”. 4-3 DIII-NET Engineering
Install pre-engineering data and Layout View data. 4-10 Installation
Activate optional maker functions.
Enable dealer options.
* When necessary
5-1 Activation
Entering the Activation key
5-2 Dealer Option Setup

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
7
2-2 Logging into Service Mode
To run engineering, you must log into the Service (SE) Mode from the Menu List screen.
In the SE Mode, the Service Settings tab, which is normally hidden, is displayed on the Menu List.
Also, special buttons available only in SE Mode are displayed on the tabs.
The following describes how to log into the SE Mode.
1. Display the Menu List screen.
(1)
(3)
(2) (4)
2. Touch the four corners of the screen in the indicated order. The Password Input dialog appears.
3. Enter the service password (daikin) and touch the OK button to log into the SE Mode.

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
8
Furthermore, if the screen is locked, entering the service password instead of the administrator
password after carrying out the special operation indicated below, allows you to unlock the
screen and log into the SE Mode.
(1)
(4)
(2)
(3)

Commissioning Manual EM11A021
DCM601A51 intelligent Touch Manager
9
3. Detailed Screen Description
3-1 Setup Screen Structure
Service Settings Tab
A/C Auto Regist
Mgmt. Point Data Regist
Other Setting
DIII-NET Engineering
Time Zone
Changeover Option
History Mgmt. (Delete)
Pre-engineering
Upgrade
Backup
Installation
Contact Info
Setting outdoor unit
Leakage Check
Activation
Dealer Option Setup
System Settings Tab
Network
Web Remote Management
Displays a list of functions configurable by service engineers
This function automatically registers air conditioners that are
not yet registered as management points
This function allows you to manually register, edit, or delete
management points
Allows you to configure the error detection level and enable or
disable the Dry mode
Allows you to switch the master and slave settings and, when
used in conjunction with an upper level central controller,
configure the setpoint limitation function
Allows you to configure the time difference between the UTC
(Universal Time Coordinated) and the local time
This function allows you to configure or cancel the
cooling / heating selection right
This function allows you to delete the history data
This tool allows you to preconfigure necessary settings on the PC
Allows you to write a new system file for upgrade
This function allows you to read the current system file and
configuration data
This function allows you to install the data for upgrade or
restoration
Configure the contact information for inquires about system
errors or other problems
Configure the model type of the outdoor unit
This function automatically detects refrigerant leak
This function allows you to enter the Activation key required
to activate a manufacturer option
Allows you to enable or disable a dealer option
Displays a list of functions related with system settings
Allows you to configure the network IP address and other
related settings
Allows you to configure the Web Remote Management user
(See page 10.)
(See page 10.)
(See page 13.)
(See page 38.)
(See page 39.)
(See page 41.)
(See page 41.)
(See page 43.)
(See page 44.)
(See page 55.)
(See page 56.)
(See page 58.)
(See page 60.)
(See page 62.)
(See page 69.)
(See page 84.)
(See page 86.)
(See page 12.)
(See page 87.)
(See page 90.)
Basic Functions
Names and Functions
Other manuals for DCM601A51
4
Table of contents
Other Daikin Control Panel manuals