Dacor MHTW36 User manual

IMPORTANT
1. Before beginning installation, please thoroughly read and become familiar with these instructions.
2. Installation and service must be completed by a qualified installer or service agency.
3. Installer: Please leave these Installation Instructions with the owner.
4. Owner: Please keep these instructions for local electrical inspector’s use and for future reference.
5. Read the accompanying Use & Care Manual prior to operating this appliance.
TABLE OF CONTENTS
Verifying package contents Page 2
Installation instructions Page 2
General instructions Page 2
Cabinet preparation Page 2
Duct planning Pages 2-3
Electrical power supply requirements Page 3
Power supply connection Pages 3-4
Fixing to the wall Page 4
Fixing the decorative telescopic flue Page 4
Verifying proper operation Page 5
Part No. 65508 Rev. A
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND
CAN/CSA-C22.2 NO. 113 STANDARD FOR FANS AND VENTILATORS.
NOTES:
Contain helpful hints and tips to facilitate the installation.
CONVENTIONS USED IN THESE INSTRUCTIONS
WARNINGS:
Must be followed carefully to avoid personal injury or damage.
SAVE AND READ THESE INSTRUCTIONS
Installation Instructions
Range Hood

1
WARNING:
TO REDUCE THE RISK OF A
RANGE TOP GREASE FIRE:
a) Never leave surface units
unattended at high settings.
Boilovers cause smoking and
greasy spillovers that may
ignite. Heat oils slowly on low
or medium settings.
b) Always turn hood ON when
cooking at high heat or when
flambeing food (i.e. Crepes
Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans
frequently. Grease should not
be allowed to accumulate on
fan or filter.
d) Use proper pan size. Always
use cookware appropriate
for the size of the surface
element.
WARNING:
TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF
A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a
close-fitting lid, cookie sheet,
or metal tray, then turn off
the burner. BE CAREFUL
TO PREVENT BURNS. If
the flames do not go out
immediately, EVACUATE
AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING
PAN - You may be burned.
c) DO NOT USE WATER,
including wet dishcloths
or towels - a violent steam
explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class
ABC extinguisher, and you
already know how to
operate it.
2) The fire is small and
contained in the area where
it started.
3) The fire department is
being called.
4) You can fight the fire with
your back to an exit.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE
FOLLOWING:
a) Use this unit only in the
manner intended by the
manufacturer. If you have
questions, contact the
manufacturer.
b) Before servicing or cleaning
unit, switch power off at
service panel and lock
the service disconnecting
means to prevent power
from being switched on
accidentally. When the service
disconnecting means cannot
be locked, securely fasten a
prominent warning device,
such as a tag, to the service
panel.
CAUTION:
For General Ventilating Use Only.
Do Not Use To Exhaust Hazardous
Or Explosive Materials And
Vapors.
IMPORTANT SAFETY INSTRUCTIONS

2
Verifying the Package Contents
• Use & Care Manual
• Hold Down Bracket Kit
• Cleaning Kit
• Grate/Burner Cap Pack
• Burner Set
• Gas Pressure Regulator
General Instructions
Carefully read the following important
information regarding installation safety and
maintenance. Keep this information booklet
accessible for further consultations.
The appliance has been designed for use in the
ducting version (air exhaust to the outside).
Installation Instructions
WARNINGS:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE
FOLLOWING:
1. Installation work and
electrical wiring must be
done by qualified person(s)
in accordance with all
applicable codes and
standards, including fire-rated
construction.
2. Sufficient air is needed
for proper combustion
and exhausting of gases
through the flue (chimney)
of fuel burning equipment
to prevent back drafting.
Follow the heating equipment
manufacturer’s guideline
and safety standards such
as those published by the
National Fire Protection
Association (NFPA), and
the American Society for
Heating, Refrigeration and
Air Conditioning Engineers
(ASHRAE), and the local code
authorities.
3. When cutting or drilling into
wall or ceiling, do not damage
electrical wiring and other
hidden utilities.
4. Ducted fans must always be
vented to the outdoors.
5. This unit must be grounded.
WARNING:
TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCTWORK.
WARNINGS:
UNDER CERTAIN
CIRCUMSTANCES DOMESTIC
APPLIANCES MAY BE
DANGEROUS.
1. Do not check filters with hood
working.
2. Do not touch the lamps
after a prolonged use of the
appliance.
3. No food must be cooked
flambè underneath the hood.
4. The use of an unprotected
flame is dangerous for the
filters and could cause fires.
5. Watch constantly the fried
food in order to avoid the
cooking oil flares up.
6. Before performing any
mainteinance operation,
disconnect the hood from the
electrical service.
NOTE:
The manufacturers will not accept
any responsibility for eventual
damages, because of failure to
observe the above instructions.
NOTES:
1. Minimum hood clearances are
zero inches (0”) to the rear,
sides and top of the hood.
2. 26” (660mm) Min. distance
from electric cooktop surface
to bottom of hood.
3. 30” (762mm) Min. distance
from gas cooktop surface to
bottom of hood.
Cabinet Preparation
26" (660mm) Min. from electric cooktop surface to bottom of hood
30” (762mm) Min. from gas cooktop surface to bottom of hood
36”
(914mm)
Cabinetry Planning
WARNING:
Failure to provide proper
minimum clearance may result in
a fire or safety hazard.
WARNINGS:
1. CAUTION: To reduce the
risk of fire and to properly
exhaust air, be sure to duct air
outside. Do not vent exhaust
air into spaces within walls or
ceilings, or into attics, crawl
spaces or garages.
2. Tape all duct joints securely
to prevent combustion by-
products, smoke or odors
from entering the home. This
will also improve the efficiency
of the system.
3. Do not exhaust more than one
vent into a single duct run.
4. Only use ductwork
constructed of materials
deemed acceptable by state,
municipal and local codes.
Duct Planning
NOTES:
1. Best performance is achieved
by using round duct instead of
rectangular, especially when
elbows are required.
2. If multiple elbows are
needed, ensure that there is
a minimum of 24” of straight
duct between any two elbows.
3. Avoid “S” or “back to back”
configurations caused by
adjacent elbows.
4. Thermal breaks, such as a
short section of non-metallic
duct, should be used in areas
of extreme cold.
5. A back-draft damper at the
duct outlet may also be
required.
6. Do not use flexible metal duct.
7. Do not use ductwork that is
smaller in cross-sectional area
than the recommended size
duct.
8. Do not rely on duct tape alone
to seal duct joints. Use sheet
metal screws as require to
support the duct weight.
9. The vent hood and cooking
appliance(s) must be
removable if service is
required.
10. Be certain that the ductwork
does not interfere with floor
joists or wall studs.
11. It is important to keep as few
turns in the duct run, and
to keep the run as short as
possible.

3
Removing Anti-Grease Filter
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE
FOLLOWING:
1. Before making electrical
connections to power supply,
the electrical box must be
secured in place as indicated
below.
Before installing the appliance, fix the electrical box
as indicated below:
1. Remove the central screw.
Removing Central Screw
2. Lift the electrical plant box.
Lifting Electrical Plant Box
Power Supply Connection
For connection to the power supply refer to the
following:
BLACK = L line
WHITE = N neutral
GREEN/YELLOW = G ground
A double-pole switch properly rated must be
installed to provide the range hood power supply
disconnection.
Connecting Power Supply
Refer above for recommended
maximum straight lengths of duct to
provide adequate performance. Refer
above for recommended sheet metal
elbows, transitions, and wall cap
equivalent straight lengths.
NOTE:
The In Line Blower must be
located within 60 equivalent feet
of the hood canopy system.
Model
Number
Duct
Size
Maximum Equivalent Straight Lengths
Internal ILB8 REMP3 ILB8 & REMP3
MHTW36
8” Round 60’ 140’ 140’ -
10” Round 50’ 100’ 100’ -
3 1/4” x 10” 50’ 100’ 100’ -
Recommended Maximum Straight Lengths
3 1/4" x 10" 90û Elbow 3 1/4" x 10" 45û Elbow 3 1/4" x 10" Wall Cap 3 1/4" x 10"
90û Flat Elbow
Transistion
3 1/4" x 10" to Round
45û Elbow - Round Duct 90û Transistion
3 1/4" x 10" to 8"/10” Round
90û Elbow - Round Duct
15 Feet 7 Feet 2 Feet 20 Feet
8" Diameter - 4 Feet
10" Diameter - 4 Feet
8" Diameter - 3 Feet
10" Diameter - 2 Feet
25 Feet 8" Diameter - 7 Feet
10" Diameter - 5 Feet
Recommended sheet metal elbows, transition, and wall cap equivalent straight lengths
Electrical Power Supply
Requirements
NOTES:
1. If the power supply
requirements shown do
not agree with those listed
on the product data plate,
provide a power source per
the information found on the
product data plate.
2. If the electrical service
provided does not meet the
product specification, or
does not conform to the NEC
or local standards, do not
proceed with the installation.
Call a licensed electrician to
correct the electrical service
before proceeding.
3. It is the owner’s responsibility
to ensure that electrical
installation of this appliance
is performed by a qualified
electrician. The electrical
installation must comply
Electrical Supply Requirements
120VAC, 60 Hz, 15A Dedicated Circuit
Total Connected Load 1.4kW (8A)
The correct voltage, frequency, and amperage
must be supplied to the appliance from a
separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse.
Refer to the data plate located on the blower
housing, inside the filter area, and/or to Table
below.
with the National Electric
Code ANSI/NFPA 70-1990 (or
to latest revision) and local
codes and ordinances.
4. Failure to disconnect electric
power may result in electrical
shock or fire hazard.
If a connection ductwork composed of two parts
is used, the upper part must be placed outside
the lower part. Do not connect the range hood
exhaust duct air to the same duct air used to
exhaust hot air or fumes from other appliances
other than electrical. Before proceeding with the
assembly operations, remove the anti-grease
filter(s) so that the unit is easier to handle.

4
3. Remove the 3 fixed screws.
Removing Fixed Screws
4. Position the electrical box so it is in line
with the holes of the previously removed
screws and tighten.
Position Electrical Box
5. Pay attention that the tear tape of the
electrical box is inside the slot and then
tighten screw.
Tightening Screws
Fixing to the Wall
Drill the holes “A” respecting the distances
indicated below.
“A”
5/8” (16mm)
9 1/4”
(235mm)
Fixing to the Wall
Fix the appliance to the wall and align it in
horizontal position to the wall units. When the
appliance has been adjusted, definitely fix the
hood using the screws “B” shown below.
“B”
For the various installations use screws and
screw anchors suited to the type of wall (e.g.
reinforced concrete, plasterboard, etc.). If the
screws and screw anchors are provided with the
product, check that they are suitable for the type
of wall on which the hood is to be fixed.
Fixing the Hood
Fixing the Decorative
Telescopic Flue
Arrange the electrical power supply within
the dimensions of the decorative flue. If your
appliance is to be installed in the ducting version
or in the version with external motor, prepare
the air exhaust opening.
Adjust the width of the support bracket of the
upper flue.
“C”
Support Bracket
Then fix it to the ceiling using the screws “C” (as
shown above) in such a way that it is in line with
your hood and respecting the distance from the
ceiling indicated in the image to the left.
Connect the flange “D” to the air exhaust hole
using a connection pipe.
“D”
“E”
Insert the upper flue into the lower flue. Fix
the lower flue to the hood using the screws “E”
provided (as shown above), extract the upper
flue up to the bracket and fix it with the screws
“F” (as shown below).
“F”
Fixing Lower Flue to Hood
Fixing Upper Flue to Hood

5
Verifying Proper Operation
WARNINGS:
If the hood does not operate
properly, follow these
troubleshooting steps:
1. Verify that power is being
supplied to the hood.
2. Check the electrical
connections to ensure that
the installation has been
completed correctly.
3. Repeat the above test.
4. If the appliance still does not
work, contact an authorized
DACOR service company.
If you are unable to locate
a DACOR Servicer, please
contact DACOR at (800)
793-0093, or visit us on the
web at www.dacor.com. Do
not attempt to repair the
appliance yourself. DACOR
is not responsible for service
required to correct a faulty
installation.
For
Placement
Only

6
NOTES:

Web Site: www.dacor.com
Phone: (800) 793-0093
Table of contents
Other Dacor Ventilation Hood manuals

Dacor
Dacor DHD U990W/DA Series User manual

Dacor
Dacor HWHE30 User manual

Dacor
Dacor ERV3615 User manual

Dacor
Dacor DHD30M700WS User manual

Dacor
Dacor PHG30 User manual

Dacor
Dacor DHI361 User manual

Dacor
Dacor Renaissance RNIVS2 User manual

Dacor
Dacor DHD30M967 User manual

Dacor
Dacor RNHP30 Renaissance User manual

Dacor
Dacor EHD3018 User manual

Dacor
Dacor RNHP3012 User manual

Dacor
Dacor DHW301 User manual

Dacor
Dacor DH3006 User manual

Dacor
Dacor RNHP36 Renaissance User manual

Dacor
Dacor RV30 User manual

Dacor
Dacor HWHE36 User manual

Dacor
Dacor EPICURE EH30 User manual

Dacor
Dacor EH3618SCH Quick start guide

Dacor
Dacor Preference PHW301 Owner's manual

Dacor
Dacor ERV48 User manual