1. IMPORTANT PRECAUTIONS ............................................................................................................4
2. SYSTEM SPECIFICATIONS ................................................................................................................5
3. PACKAGE CONTENTS.......................................................................................................................5
4. INSTALLATION REQUIREMENTS......................................................................................................6
4.1. Power Outlets .........................................................................................................................6
4.2. Wasp installation ....................................................................................................................6
4.3. Example Indoor cycling area layout........................................................................................7
4.4. Drilling template .....................................................................................................................8
5. NOT INCLUDED WITH THE ICG CONNECT SYSTEM .........................................................................8
Indoor Cycles.......................................................................................................................................8
External video device:.........................................................................................................................8
External video device cable: ...............................................................................................................8
Wasp Network cables .........................................................................................................................8
Network Cable / Connection to Internet for updating .......................................................................8
6. UNBOXING ......................................................................................................................................9
INSTALLATION.........................................................................................................................................9
7. Assembly & Connection................................................................................................................10
8. CONNECTION SCHEMATIC ............................................................................................................13
9. TURNING ON THE ICG CONNECT SYSTEM.....................................................................................14
10. SETTINGS MENU........................................................................................................................14
Entering the Settings Menu ..............................................................................................................14
11. SETTINGS...................................................................................................................................15
TIME AND DATE SETUP .....................................................................................................................15
LANGUAGE........................................................................................................................................15
METRIC..............................................................................................................................................15
HDMI AUDIO .....................................................................................................................................15
DEMO MODE.....................................................................................................................................15
SYSTEM INFORMATION.....................................................................................................................15
12. Software updates......................................................................................................................15
12.1. Update via USB Flash drive ...............................................................................................15
12.2. Update via ethernet cable and internet connection. .......................................................22
CLEANING THE ICG CONNECT SYSTEM .................................................................................................26
WARRANTY ...........................................................................................................................................26

1. IMPORTANT PRECAUTIONS
1. It is the sole responsibility of the owner/operator and his staff to ensure that all users are informed of all warnings
and precautions prior to using the ICG CONNECT SYSTEM.
2. Position the ICG CONNECT SYSTEM next to the Indoor Cycle on a level surface as recommended in the installation
guide. Be sure there is enough space around the ICG CONNECT SYSTEM to mount, dismount and operate the
equipment safely.
3. ICG CONNECT SYSTEM is intended for indoor use only. Keep the equipment away from moisture and dust. Do not
place the training equipment in a garage, covered patio, near water or pools. Operating temperature of the
equipment must be between 15°C~ 40°C Celsius (59°~104°F) at max. humidity of 65%.
4. Regularly inspect all parts of the ICG CONNECT SYSTEM. Please replace defective parts immediately and do not use
the equipment until repairs are carried out. Only use original parts from the manufacturer.
5. Keep unattended children away from the ICG CONNECT SYSTEM.
6. WARNING: The training equipment can be used by children aged from 14 years and above and persons with lack of
experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Persons with reduced physical, sensory, or mental capabilities are
prohibited from using the training equipment. Children shall not play with the training equipment. Cleaning and
user maintenance shall not be made by children without supervision.
7. To ensure the level of safety of the ICG CONNECT SYSTEM a regular maintenance is mandatory.
MEDICAL DISCLAIMER!
Not all exercise programs are suitable for everyone. Please consult your physician before beginning this or any other
exercise program. ICG CONNECT programs are designed for fit, healthy, able-bodied users. Any action in response to
the instructions provided in this program is at user discretion. You should always warm up for a few minutes before
beginning any workout, and you should never exercise beyond the level at which you feel comfortable. The usage of a
heart rate monitor is highly recommended!
If at any time you feel you are exercising beyond your current fitness abilities, or you feel discomfort, you must stop
your workout immediately! The user assumes all risk of injury in the use of this program.
WARNING: To prevent damage, do not move the unit while the Power, HDMI or Ethernet Cables are connected to the
System.
WARNING: To prevent risk of electric shock or fire, do not allow this system to become wet.
Do not expose the ICG CONNECT SYSTEM to moist environments, and do not place liquid filled containers on or near the
unit.
ATTENTION: To prevent a risk of electric shock, be sure the power plug is fully and correctly inserted into the wall socket.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN!
High voltage is present within the enclosure. Do not open the housing.
Only trained and qualified ICG / Life Fitness service technicians may service the ICG CONNECT SYSTEM.

2. SYSTEM SPECIFICATIONS
ASSEMBLED DIMENSIONS: 53.5 x 36 x 116CM / 22 x 14 x 46IN
ASSEMBLED WEIGHT: 23KG / 51LBS
OPERATING SYSTEM (OS): ICG Customized Linux OS
COMPUTER: AMD Ryzen R1505 APU
ASPECT RATIO: 16:9 (External Screen)
SCREEN VIEWING POSITION: Adjustable - Tilt & Pivot (rotation)
VIDEO RESOLUTION: Full HD 1080P
SOFTWARE UPDATE: Internet via Ethernet cable / USB Flashdrive
USB : 1 x 2.0
HDMI : 1 x 1.3
AUDIO PORT : 1 x 3.5MM input
ETHERNET PORT: RJ45
DISPL AY TYPE: 39CM / 15.6IN IPS Panel with capacitive touch
POWER REQUIREMENTS: 110-220v AC input
LEVELLING FEET: 2
TRANSPORT WHEELS: 2
WARRANTY (PARTS) 1 Year mechanical and electronic components
3. PACKAGE CONTENTS
REF.
QTY
Description
A
1
Pre- assembled ICG CONNECT SYSTEM
B
4
ICG CONNECT SYSTEM POWER CABLES
EUROPE: CEE 7/7 TYPE F
US: NEMA-5 TYPE B
UK: BS 1363
AU: AS 3112 TYPE I
C
2
WASP (RECEIVER FOR ANT DATA FROM IC5, 6, 7 & 8 INDOOR CYCLES
D
2
CAT 5 RJ45 NETWORK CABLES FOR TESTING SYSTEM FUNCTIONALITY 1 METER (3 FEET)
A
B
C
D

4. INSTALLATION REQUIREMENTS
The following requirements must be met for installation and use of the ICG CONNECT SYSTEM.
4.1. Power Outlets
The ICG CONNECT SYSTEM requires one power outlet with 110/220V AC output
4.2. Wasp installation
The ICG CONNECT SYSTEM requires installation of the Cat 5 or better network cables for optimal positioning of the supplied
WASPS. The layout of the indoor cycling area may vary from facility to facility and therefore the sourcing of the network
cables and installation is the responsibility of the customer.
Network cable requirements (WASPS)
Cat 5 or better network cables / Max. cable length: 50m (164 feet) not included in scope of delivery.
The Wasps should be positioned for optimal coverage of the indoor cycling area with no greater distance than approx. 5m in
direct line of sight to the furthest bike for best results.

4.3. Example Indoor cycling area layout.
TV / External
video device
ICG CONNECT SYSTEM
Trainer Bike
WASP
WASP
WASP Network
cable
WASP Network
cable
HDMI cable
Power Cable

4.4. Drilling template
The Wasps can be mounted according to the
Drilling template (hardware not included).
5. NOT INCLUDED WITH THE ICG CONNECT SYSTEM
Indoor Cycles
The ICG CONNECT SYSTEM only works with IC5, IC6, IC7 & IC8 series bikes.
External video device:
TV or Projector
Resolution: 1080P
Input: HDMI 1.3
External video device cable:
High Speed HDMI Cable
Max. length 10m (32 feet)
Wasp Network cables
Cat 5 or better network cables / Max. cable length: 50m (164 feet) not included in scope of delivery.
Network Cable / Connection to Internet for updating
The ICG CONNECT SYSTEM does not require an internet connection for operation. A connection is optional for software
updates. Software updates can also be installed by downloading the required file to a USB Flashdrive.

6. UNBOXING
1. Position the box on side and open it as shown below. Lift the ICG CONNECT SYSTEM from
the box. Take note to remove any hardware taped to the Styrofoam inside the packaging.
Open the box from the side and remove the Styrofoam and the unit from the box. Be careful not to damage the contents
when opening.
INSTALLATION
Unboxing Video: / https://youtu.be/1PzuLkx7Nmo

7. Assembly & Connection
1. Remove the 3mm Hex screw from the rear of the base.
2. The panel is hinged on the left side. Pull the panel from the right side.
Table of contents
Other Cytech Home Automation manuals