Condari QASAIR 4F Assembly Instructions

ISLAND
INSTALLATION & USER
INSTRUCTIONS

Qasair Rangehoods Installation Instructions2

Qasair Rangehoods Installation Instructions 3
Standard Warranty / Extended Warranty
Important Information
Instructions for Models
4F / PRE / FRA / MA / SQ 420 / MOL / FPR / BUR / BEL
Instructions for Models
D 400 / D 500 / SEN
Instructions for Models
TR CT / LIV
Installation Ideas
Operation Details, Rangehood Cleaning, Filter Cleaning
Ducting Pieces
Remote Switching Specications
Appliance Guarantee
Guarantee Exclusions
6
4
20
23
26
29
42
47
50
49
48

Qasair Rangehoods Installation Instructions4
The installation of QASAIR Rangehoods must comply with the information in this booklet. QASAIR Rangehoods are
designed and made to work efciently over all domestic cookware available on the Australian market.
Clearance from cooktop to Rangehood
For electric hot plate cooktops
As there are no regulations for Rangehoods over an electric hot plate, please follow the manufacturers Instructions /
Recommendations.
For Induction cooktops
Induction cooktops may present problems with condensation on lters of Rangehoods.
All Qasair Rangehoods installed above an induction cooktop must be installed no less than 750mm between the
induction cooktop and the Rangehood, with the exception of the Eastmore (EAS) Rangehood which can be installed
no less than 600mm. Undermount (NDCH) and Conley (CON) Rangehoods are not suitable for induction cooktops.
For gas cooktops
All Qasair Rangehood installations over a gas appliance must comply with (AS/NZS 5601.1).
The Regulations for the installation of Gas Appliances (AS/NZS 5601.1) states that the clearance between the
highest part of the burner of a gas cooking appliance and a Rangehood be no less than 600mm. If the gas
appliance is designed for use without a cooking vessel like an indoor barbecue or open ame grill, then the
clearance from the cooking surface to the Rangehood shall be no less than 1200mm.
All Qasair Rangehoods installed above a gas cooktop must be installed no less than 600mm between the highest
part of the burner and the Rangehood.
The recommendation for Qasair Wallmount Rangehoods is that they be installed between 700 to 800mm above the
highest part of the burner. When the Rangehood is installed in a galley or partially enclosed kitchen the Rangehood
can be installed between 900 to 1000mm above the highest part of the burner.
Qasair Island Rangehoods should not be installed any higher than 800mm above the highest part of the burner as
any movement around the bench will result in fumes being drawn out from the catchment area of the Rangehood
with the exception of the Thermidor and Liverpool which for aesthetic reasons is installed ush with the ceiling.
Ducting
1. Every QASAIR Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or
non-porous and non-ammable materials. Do not use of any type of exible ducting or plastic PVC piping.
Rangehoods must not be vented into a wall cavity or a ceiling space. Externally ducting the rangehood prevents
a build up of grease, which can be a re risk. Ensure the external outlet vent does not restrict the airow in any
way, as this may result in reduced performance.
2. QASAIR Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: The cross
sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have
sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to
ensure optimum performance. Always use nonammable materials to minimise the risk of re in the duct.
3. Ensure all ducting pieces are correctly tted and sealed with either duct tape or silicone to ensure that fumes
do not escape into the ceiling space and seep into living areas through vents or light ttings.
IMPORTANT INFORMATION

Qasair Rangehoods Installation Instructions 5
Other Important Information
1. Always adequately ventilate the room when the rangehood is in use at the same time as appliances
burning gas or other fuels.
2. WARNING: Incorrect venting will result in additional noise and a reduction in efciency. Exhaust air must not be
discharged into any chimney or ue, which may carry combustible products from other sources.
a) Do not discharge the air-ow from the rangehood into a ue used for exhausting fumes
from burning gas or fuel;
b) For cleaning purposes please refer to page 47 of installation instructions for stainless steel;
c) If cleaning is not carried out in accordance with the instructions as listed on page 47, there may be an
increased risk of re;
d) Some parts of the rangehood may become hot when cooking;
e) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
3. The installation and tting of the rangehood should be done in such a way that will allow the unit to be removed
if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not
covered by warranty.
4. To reduce the risk of xing screws coming in contact with live parts, do not drill or screw into the rangehood.
Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and
only through single sheet material.
5. NOTE: CONDARI recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor
barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues
for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted
and not near the outer edges where leakage may occur.
6. The lights in the rangehoods are LED and come with a night light except for D400L-1 and SEN400L-1.
7. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.
8. Do not ambé under the rangehood.
9. QASAIR domestic rangehoods must not to be used over barbecues approved for outdoor use only,
CONDARI make a range of hoods specically for outdoor barbecues in alfresco areas under the CONDOR
name.
10. CONDARI can manufacture rangehoods to be used over commercial cookers in domestic applications.
12. NOTE: Ensure all requirements are met with gas and electrical regulations and or state authorities.

Qasair Rangehoods Installation Instructions
6
INSTALLATION INSTRUCTIONS
• 4F
• PRE / FRA
• MA
• SQ 420 / MOL
• FPR
• BUR / BEL
• D 400 / D 500 / SEN
It is recommended that the rangehood be mounted 100mm back from the edge of the benchtop.
1. The rangehood can be installed between 700mm and 800mm above the cooking surface. The installer should
check for local requirements in case additional provisions apply.
2. It is advisable to remove fans for easier handling of unit by removing retaining bolts or clips and unplugging
electrical connector.
3. Measure hole centres and duct size on top of the rangehood. This will vary with the hood size, model and
number of fans fitted and will determine the ducting required.
4. Using a plumb line, mark the ceiling before making the cut out. Check for obstructions like electrical cables etc.
5. Cut two (2) supporting beams approximately 1.0m long and pre-drill hole centres so that the supporting beams
are 90 degrees to the ceiling joists.
6. Fit 8mm all thread (threaded rod) through holes provided and secure with nuts and washers.
7. Level unit by tensioning the 8mm nuts. Do not over tighten.
8. Fit off ducting as required.
Installation Suggestions
1) 2)

Qasair Rangehoods Installation Instructions
7
4 Flare
Technical Specification Sheet
4F Ceiling Mounted
PMS 539C
R= 0
G= 48
B= 73
PMS 5503C
R= 156
G= 197
B= 202
Model 4F 1000L-2 4F 1200L-2
Body Width 429mm x 260mm
Corner Type
Condari Pty Ltd.
All-thread
Fixing Centres
Conversion
Top/Back Back/Top
Filter Size
3
YES
PowderKote
Available
300mm x 200mm
Version: D 20/03/2017F Page 1 of 1
380mm
Maximum Height
(H =)
350mm x 200mm
YES
Round
1660mm
N/A
480mm
6
Cool
2
4
430mm
Light Qty
Filter Qty
Light Centres
Nightlight
Motor Qty
LED Light
Motor Box /
Flue Width
Minimum Height
(H =)
Round
YES
Model4F 1200L-24F 1000L-2
10 Amp Lead
Cool
1000mm
350mm
2
400mm
1200mm
YES
2
Electrical Connection 10 Amp Lead
N/A
355mm x 250mm
480mm
1660mm
Power Entry
Ø15mm Radius
Power Entry
A Transition is supplied to suit standard DL2 ducting.
B
o
d
y
W
i
d
t
h
F
l
u
e
W
i
d
t
h
700
80
480
H
250
Ø15mm Radius
A
l
l
-
T
h
r
e
a
d
1
1
5
B
o
d
y
W
i
d
t
h
F
l
u
e
W
i
d
th
1
1
5
A
ll
-
T
h
r
e
a
d
210
2
6
0
A
l
l
-
T
h
r
e
a
d
A
l
l
-
T
h
r
e
a
d
2
6
0
4 FLARE - 4F

Qasair Rangehoods Installation Instructions
8
President
Technical Specification Sheet
PRE Ceiling Mounted
PMS 539C
R= 0
G= 48
B= 73
PMS 5503C
R= 156
G= 197
B= 202
Model
Body Width
Motor Box /
Flue Width
PRE 1000L-2
Condari Pty Ltd.
Corner Type
Motor Qty
Nightlight
Light Qty
All-thread
Fixing Centres
Maximum Height
(H =)
6
380mm430mm
Cool
4
Filter Qty
Light Centres
LED Light
360mm x 320mm 360mm x 320mm
1600mm
YES
429mm x 260mm
PRE 1000L-2
Electrical Connection
NO
550mm
10 Amp Lead
Version: D 28/03/2017F
Round
550mm
YES
Page 1 of 2
Round
1000mm
420mm
2
YES
2
PRE 1200L-2 Model
1600mm
NO
10 Amp Lead
PowderKote
Available
Minimum Height
(H =)
3
Cool
YES
2
1200mm
420mm
Filter Size
Conversion
Top/Back Back/Top
PRE 1200L-2
355mm x 250mm
Power Entry
B
o
d
y
W
i
d
t
h
100
H
85 85250
420
1
4
0
M
o
t
o
r
B
o
x
W
i
d
t
h
2
5
0
A
ll
-
T
h
r
e
a
d
A
l
l
-
T
h
r
e
a
d
5
0
700
Ø15mm Radius
5
0
B
o
d
y
W
i
d
t
h
M
o
t
o
r
B
o
x
W
i
d
t
h
Power Entry
2
5
0
A
l
l
-
T
h
r
e
a
d
1
4
0
A
l
l
-
T
h
r
e
a
d
5
0
5
0
Ø15mm Radius
PRESIDENT - PRE

Qasair Rangehoods Installation Instructions
9
President
Technical Specification Sheet
PRE Ceiling Mounted
ModelPRE 1800L-3PRE1500L-3Model
Body Width
Nightlight
Light Qty
Minimum Height
(H =)
All-thread
Fixing Centres
Light Centres
LED Light
Filter Qty
Motor Qty
Motor Box /
Flue Width
Corner Type
Maximum Height
(H =)
Electrical Connection
Conversion
Top/Back Back/Top
Condari Pty Ltd.
PowderKote
Available
Filter Size
Page 1 of 2
3
Cool
YES
8
510mm
3
1500mm
900mm 900mm
1800mm
4
Cool
3
422mm
10
YES
840mm x 320mm
Round
YES
840mm x 320mm
YES
1600mm
PRE 1800L-3
10 Amp Lead
550mm
PRE 1500L-3
NO
340mm x 260mm
NO
340mm x 260mm
10 Amp Lead
Round
Version: D 28/03/2017F
1600mm
550mm
250
85
H
100
B
o
d
y
W
i
d
t
h
B
o
d
y
W
i
d
t
h
85
1
4
0
M
o
t
o
r
B
o
x
W
i
d
t
h
M
o
t
o
r
B
o
x
W
i
d
t
h
420
A
l
l
-
T
h
r
e
a
d
5
0
A
l
l
-
T
h
r
e
a
d
1
4
0
A
l
l
-
T
h
r
e
a
d
4
5
0
5
0
A
l
l
-
T
h
r
e
a
d
Power Entry
700
Ø15mm Radius
Ø15mm Radius
Power Entry
4
5
0
5
0
5
0
PRESIDENT - PRE

Qasair Rangehoods Installation Instructions
10
Franklyn
Technical Specification Sheet
FRA Ceiling Mounted
Model
Body Width
Motor Box /
Flue Width
FRA 1000L-2
Condari Pty Ltd.
Corner Type
Motor Qty
Nightlight
Light Qty
All-thread
Fixing Centres
Maximum Height
(H =)
6
380mm430mm
Cool
3
Filter Qty
Light Centres
LED Light
360mm x 320mm 360mm x 320mm
1600mm
N/A
429mm x 260mm
FRA 1000L-2
Electrical Connection
NO
550mm
10 Amp Lead
Version: C 12/12/2017F
Square
550mm
N/A
Page 1 of 2
Square
1000mm
420mm
2
YES
2
FRA 1200L-2 Model
1600mm
NO
10 Amp Lead
PowderKote }
Available
Minimum Height
(H =)
3
Cool
YES
2
1200mm
420mm
Filter Size
Conversion
Top/Back Back/Top
FRA 1200L-2
350mm x 250mm
Power Entry
700
100
H
85 85250
420
Front
Front
Power Entry
FRANKLYN - FRA
This manual suits for next models
13
Table of contents
Other Condari Ventilation Hood manuals