Comfort audio Sync DY10 User manual

Sync
DY10
Comfort Digisystem User Manual
SecureStream
Technology
English

2
Sync DY10
User Manual
Contents Page
Introduction to Comfort Digisystem 3
Introducing Sync DY10 4
Functions – Sync DY10 5
Getting started 6
First use 7
Menu 9
Radio range and channels 14
Accessories included 14
Troubleshooting 15
Service and warranty 15
Technical data 15
Important safety instructions 16
Mounting Instructions 19

3
Sync DY10
Introduction to Comfort Digisystem
Thank you for choosing Comfort Digisystem. The products are easy to
use, irrespective of whether or not you have a hearing aid.
Before using the product, please read through the User Manual.
Comfort Digisystem is equipped with SST – SecureStream Technology –
digital technology that enables interception-proof radio transmission in
real time.

4
Sync DY10
Introducing Sync DY10
Sync DY10 is a device that is mounted on the wall or placed on a table in,
for example, a classroom, a lecture hall or a conference room.
The purpose of the DY10 is to give people carrying around one or more
Comfort Digisystem units easy access to the right channels and the
code key for the system used in the premises, i.e. so that the units are
synchronised.
The only thing the user needs to do is, in the vicinity of the Sync DY10,
to activate the pairing mode for its Comfort Digisystem unit. For most
products this is done by keeping the pairing button pressed in for more
than 1second.
In this way, the user does not need to enter manual settings and changes;
these are managed automatically.
This procedure has to be gone through again when the user subsequently
wants to connect to another system. All Comfort Digisystem units retain
the set channel and code key even when the units are turned off. DY10
can be used for both single and dual channel systems. In dual chan-
nel systems, a main channel is used for the transmission of all sounds,
and a connecting channel for sounds from, for example, a push-to-talk
microphone. Sync DY10 automatically synchronises both channels to the
Comfort Digisystem product, which has both transmitters and receivers,
such as Microphone DM30.

5
Sync DY10
Functions – Sync DY10
On/Off
Display
Function indicator
Locking screw for
wall mounting
Screw mounting
Screw mounting
Function button
Menu button
Function button
Strain relief for
charging cable Charge socket

6
Sync DY10
Getting started
Charging and mains connection
Sync DY10 is rechargeable, but is usually powered by mains electricity.
For battery operation
DY10 must be charged for at least two hours before first use. An empty
battery takes around two hours to charge fully.
The charge indication is shown on the display. When the unit is fully
charged, it switches to float charging. If battery operation is activated, the
unit can operate for up to 40 hours in the event, for example, of a power
failure. If the power failure lasts longer, the unit starts up automatically
when power returns.
You cannot change the battery yourself; please contact your point of
purchase.
Connecting the charger to Sync DY10
NB!
Use only the supplied charger
from Comfort Audio AB.
ABC

7
Sync DY10
First use
Wall mounting
Mount the brackets for Sync DY10 on the wall. You can use the accompa-
nying drilling template at the back of the manual for correct positioning.
Freely positioned unit
Sync DY10 can also be placed on a table. The unit will not move, thanks to
the soft rubber frame on the bottom of the unit.
Start
Make sure the unit's charger is connected.
Start DY10 by simultaneously pressing and on the back of the unit;
the display lights up. The unit is switched off in the same way by pressing
both buttons simultaneously.
If the charger is not connected when DY10 starts, the question “Active
Battery backup?” appears. If you want to start Sync DY10 without
connecting the charger, select “Yes”. If, however, you would prefer not
to activate battery operation, select “No” and ensure that the charger is
connected before starting the unit again.
start up?
Switching the Sync DY10 on and off

8
Sync DY10
Function indication
When Sync DY10 is operational and activated (see menu section
Channels
) this is shown by means of the function indicator. When in
battery operation mode the indicator flashes, and when connected to the
mains it produces a constant white light.
Menu control
It is possible to make the following choices using the menu controls
Change language
On delivery the menu language is set to English.
Press the Menu button to enter the menu and
use the function buttons to navigate up and down:
Function button (moves the marker up)
Menu button (opens the menu/used for selection)
Function button (moves the marker down)

9
Sync DY10
In most European countries, channels 1, 2 and 3 are free channels that
do not require a licence.
Under Increased range more channels can be selected. These channels,
however, often require licences; see
Radio range and channels
.
Menu
To open the main menu, press the Menu button.
Below is a description of each menu. Use the function
buttons to move the marker up or down.
Press the Menu button to select.
Channels
Comfort Digisystem products cover widerange of different frequency
bands. Certain single channel products cover part or all of the Digisys-
tem’s frequency bands,d the dual channel products are available in dif-
ferent variants for different frequency combinations.
All channels and all channel combinations can be selected in the DY10.
When selecting channels, you must consider the environment in which
the DigiSystem will be used
Setting the Main Channel
The Main Channel is the radio channel used in single channel systems
and as the transmitting channel in a dual channel system.

10
Sync DY10
When the Active box is ticked, DY10 sends out pairing information for the
Main Channel continuously. In order for pairing information for the Con-
necting Channel to be transferred to a Comfort Digisystem product, the
Main Channel must be set and activated.
Setting the Connecting Channel
The Connecting Channel is used in a dual channel system. The Main
Channel and Connecting Channel cannot be tuned to the same or ad-
jacent frequency bands. You can opt to set the Main Channel to a high
frequency and the Connecting Channel to a low frequency, or vice versa.
Check which frequencies the Comfort Digisystem products that are to be
used in the premises are designed for.
If the Comfort Digisystem products are synchronised incorrectly or chan-
nel and frequency settings are incompatablewith the relevant channel
setting are not designed for these frequencies or frequency combina-
tions, the product displays an error message the system will display an
error message.
When the Active box is ticked, DY10 sends out pairing information for the
Connecting Channel continuously. If the Connecting Channel is not to be
used, the Active box should not be ticked.