Coldtainer T0022/FDN User manual

USER MANUAL / MANUAL DE USUARIO
MODE D’EMPLOI / MANUALE D’USO

Copyright©2020 Euroengel srl
Coldtainer™ is a trademark by Euroengel srl

ENGLISH 1
ESPANÕL 15
FRANÇAIS 31
ITALIANO 47


USER MANUAL

2
User manual
T0022/FDN, T0022/FDH, T0032/FDN, T0032/FDH, T0056/FDN, T0056/FDH,
T0082/FDN, T0082/FDH, T0082/XFDN, F0140/NDN, F0140/NDH, F0140/FDN,
F0140/FDH, F0330/NDN, F0330/NDH, F0330/FDN, F0330/FDH, F0330/XFDN,
F0440/NDN, F0440/NDH, F0440/FDN, F0440/FDH, F0650/NDN, F0650/NDH,
F0650/FDN, F0650/FDH, F0720/NDN, F0720/NDH, F0720/FDN, F0720/FDH,
F0760/NDN, F0760/NDH, F0760/FDN, F0915/NDN, F0915/NDH, F0915/FDN,
F0915/FDH, F1080/NDN, F1080/NDH, F1080/FDN, F1080/FDH, F1340/NDN,
F1340/NDH, F1640/NDN, F1640/NDH
Valid for all Coldtainer mobile fridges produced by Euroengel srl from May 2017
onwards

3
GENERAL 4
SAFETY 4
TECHNICAL NOTES 5
BEFORE USE 6
ELECTRICAL CONNECTIONS, STANDARD MODELS 6
DC connectors, fridge side 7
dc cords 7
direct connection to adc battery 7
optional - Use of the coldtainer connected to ac mains (100-240Vac 50/60 hz) 8
ELECTRICAL CONNECTIONS, “AUTONOMOUS OPERATION” MODELS
connection to ac mains (100-240Vac 50/60 hz)8
OPERATION 9
control panel 9
electronic thermostat (eVco) 9
switch on the coldtainer 10
switch off the coldtainer 10
lock / Unlock the keypad 10
modify the setpoint 10
setting configUration parameters 10
enable temperatUre decimal point 11
change temperatUre Unit of measUre (°c or °f) 11
set acabinet probe offset 11
set an high / low temperatUre alarm 11
BATTERY PROTECTION 12
SELF-DIAGNOSTIC 12
OPTIONAL – USE OF HACCP / BLUETOOTH MODULE
CLEANING AND MAINTENANCE 13
LIMITED LIABILITY 13
DISPOSAL 14
8
13

4
GENERAL
The coldtainers has been designed for the professional temperature controlled
transport of limited volumes of perishable items, like food, pharmaceuticals,
biologicals.
The units are designed, if properly operated and connected to a suitable power
source, to maintain perishable items at a stable temperature during transport, as
a link of a “cold chain” system. Units are not designed to cool down or freeze or
heat up perishable items.
The units are not intended for sale-to and use-by end consumers. The sales of
Euroengel mobile fridges do not fall within the scope of Directive 1999/44/EC or
similar end users protection legislations.
SAFETY
• Before using the unit, read these operating instructions carefully, including all
information on operating safety, use and maintenance.
• Keep these operating instructions ready at hand and leave them with the unit,
so that all users can nd out about the functions and safety regulations. Every
user must be well acquainted with the operation of the appliance and with the
instructions concerning safety. Failure to observe these instructions can impair
the performance of the appliance and cause damage.
• All installation work and adjustments to the unit must only be carried out by
qualied personnel. Work performed by persons with insufcient technical
knowledge may adversely affect the performance of the unit or cause physical
injury or damage to the equipment.
• The unit must only be used by adults. Do not allow children to play with the
units or touch the controls.
• Do not place inammable liquids or gas bottles in the cool box. Danger of
explosion!
• For large containers: never lock anybody inside. Danger of suffocation!
• Pay attention on all moving parts when closing the door. Watch out not to hurt
your hands or ngers when operating the closing mechanism.
• Be aware of the full weight of the unit you are using. Use proper lifting
equipment in the case.
• Before cleaning or carrying out maintenance work, always switch the refrigerator
off and disconnect the plug.
• The unit’s hermetic cooling system contains CFC free refrigerant gas (R134a or
R404A). Make sure to not damage the cooling system so to avoid leaks.

5
TECHNICAL NOTES
Specic versions with different internal temperature setting are available for each
container size, (ask for data sheet of single models for specic values):
• NDN: cooling function, internal temperature down to 0°C (with +32°C ambient)
NDH: automatic cooling / heating function, internal temperature from 0°C to
+30°C (with ambient temperature from -20°C to +32°C)
• NDH: automatic cooling / heating function, internal temperature from 0°C to
+30°C (with ambient temperature from -20°C to +32°C)
• FDN: freezer function, internal temperature down to -21°C (with +32°C ambient)
• FDH: automatic cooling / heating function, internal temperature from -21°C to
+30°C (with ambient temperature from -20°C to +32°C)
• XFDN: deep freezing, internal temperature down to -30°C or -35°C, according
to model (with +32°C ambient)
The coldtainers operate via direct current compressors connected to a 12-24Vdc
or 12Vdc power source (according to model). The high quality SECOP BD series
direct current compressors used in the units are designed to withstand vibrations,
also in case of use in off-road conditions, and can work with an inclination of up
than 30°.The units shall be switched off if positioned at an angle of more than 30°.
After being returned to a level position, allow to rest for approximately 30 minutes
before switching on.
SECOP compressors have built-in protection systems against overload and start
failure, fan overload, reverse polarity, overheating. When overload protection is
activated, the compressor enters a cycle in which it attempts to start at approximately
60 second intervals until a successful start is achieved. When overheating protection
is activated (i.e. ambient temperature exceed ab. +55°C) the compressor will restart
automatically approximately 60 seconds after the temperature of the electronic has
cooled down to a safe value.
If a voltage outside the specied range is applied to the electronic unit, the
compressor does not start, or it stops if the voltage limit is exceeded during
operation. The compressor will restart automatically approximately 60 seconds
after the supply voltage has reached the reset voltage within the range in question.
If a fan is installed, it will start to operate without a delay as soon as the reset
voltage is reached.
Maximum operating ambient temperature is ab. +55°C (with degraded
performances). Minimum operating ambient temperature (for NDH and FDH
models) is -20°C.
The internal temperature displayed by the digital controller is the one sensed in the
vicinity of the probe area. The temperature in other points of the container can vary,
after stabilization, normally in a ± 2°C range.
The NDH and FDH versions have an internal fan for a better internal air distribution.
An “internal fan” kit is available as accessory for the NDN, FDN and XFDN versions.
Always pre-condition the internal temperature of the unit before use. Do not place

6
any hot item inside the unit, precool them rst.
IMPORTANT: the starting current of the larger BD compressor can reach 35A (12V).
To guarantee stable operations it is essential to connect the units to batteries of
proper Ah capacity.
In case of the larger freezer versions it is recommended to use batteries with no less
than 100Ah (with150A alternators) capacity.
In case of use of a too small Ah capacity battery, even if new and well charged, the
compressor would not start. This is valid also for connection of multiple units to a
same battery.
Eventually connect the unit to a proper capacity deep cycle service battery, using a
proper split charging system to connect it to the main battery.
Even if the plastic materials (PE) used for the production of the units are food grade,
it is always suggested to store food or other products in proper closed containers.
BEFORE USE
• The units should be placed in a dry location and should not be exposed to di-
rect sun light or any other heat source (e.g. radiator). Protect it against rain and
humidity. In case on use on a pick-up truck, always use a proper cargo cover to
protect the unit.
• Always make sure there is sufcient ventilation so that heat generated during
normal operation can dissipate. Ensure that the ventilation slots are not cove-
red. Leave at least 50 mm. from top and around the unit to grant an adequate
ventilation.
• Always secure tightly the units f loaded on a vehicle, in order to prevent any
forward, side and backward movement during driving or while braking. Use
load straps, anchor points or other suitable restraints, properly homologated.
• Store the items within the fridge so that the air can circulate around the goods.
• Do not open the fridge more often than necessary and do not leave the
lid / door open for longer than necessary.
• Take care when transporting pharmaceuticals and biological products. Always
check if the temperature range of the fridge is adequate for the purpose.
• All servicing and repairs involving recharging of the cooling system must only
be carried out by a qualied customer service engineer.
ELECTRICAL CONNECTIONS, STANDARD MODELS
The coldtainers can be operated connected to following direct current power
sources:
• 12Vdc or 24Vdc (the input voltage is automatically regulated by the electronic):
T0022/FDN, T0022/FDH, T0032/FDN, T0032/FDH, T0056/FDN, T0056/FDH,
T0082/FDN, T0082/FDH, F0140/NDN, F0140/NDH, F0140/FDN, F0140/FDH,
F0330/NDN, F0330/NDH, F0330/FDN, F0330/FDH, F0720/NDN, F0720/NDH,
Other manuals for T0022/FDN
1
This manual suits for next models
44
Table of contents
Languages:
Other Coldtainer Refrigerator manuals