Code CR1000 User manual

C005905_01_CR1000_User_Manual
C005905_01_CR1000_UserManual
User Manual
Code Reader 1000™
Manual Version 01
Release Date: January 2011

C005905_01_CR1000_User_Manual
Statement of Agency Compliance
Code voids product warranty if the hard case has been opened or tampered with in any way.
In addition, a CB Test Certicate has been issued by the National Certication Board (NCB)
indicating CR1000 meets all safety and quality standards in accordance to IEC 60950-1:2001, First
Edition.
The Code Reader 1000 has been tested for compliance with FCC regulations and was found to be
compliant with all applicable FCC Rules and Regulations.
IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, this device must not
be co-located or operate in conjunction with any other antenna or transmitter.
CAUTION: Changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
The Code Reader 1000 has been tested for compliance to CE standards and guidelines and was found
to conform to applicable CE standards, specically the EMC requirements EN 55024, ESD EN 61000-4-
2, Radiated RF Immunity EN 61000-4-3, ENV 50204, EFT EN 61000-4-4, Conducted RF Immunity EN
61000-4-6, EN 55022, Class B Radiated Emissions, and Class B Conducted Emissions.

C005905_01_CR1000_User_Manual
Code Reader 1000 User Manual
Copyright © 2011 Code Corporation.
All Rights Reserved.
The software described in this manual may only be used in accordance with the terms of its license agreement.
No part of this publication may be reproduced in any form or by any means without written permission from Code
Corporation. This includes electronic or mechanical means such as photocopying or recording in information storage and
retrieval systems.
NO WARRANTY. This technical documentation is provided AS-IS. Further, the documentation does not represent a
commitment on the part of Code Corporation. Code Corporation does not warrant that it is accurate, complete or error
free. Any use of the technical documentation is at the risk of the user. Code Corporation reserves the right to make
changes in specications and other information contained in this document without prior notice, and the reader should in
all cases consult Code Corporation to determine whether any such changes have been made. Code Corporation shall
not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages
resulting from the furnishing, performance, or use of this material. Code Corporation does not assume any product liability
arising out of or in connection with the application or use of any product or application described herein.
NO LICENSE. No license is granted, either by implication, estoppel, or otherwise under any intellectual property rights
of Code Corporation. Any use of hardware, software and/or technology of Code Corporation is governed by its own
agreement.
The following are trademarks or registered trademarks of Code Corporation:
CodeXML® , Maker, QuickMaker, CodeXML® Maker, CodeXML® Maker Pro, CodeXML® Router, CodeXML® Client
SDK, CodeXML® Filter, HyperPage, CodeTrack, GoCard, GoWeb, ShortCode, GoCode®, Code Router, QuickConnect
Codes, Rule Runner®, Cortex®
All other product names mentioned in this manual may be trademarks of their respective companies and are hereby
acknowledged.
The software and/or products of Code Corporation include inventions that are patented or that are the subject of patents
pending. U.S. Patents: 6997387, 6957769, 7428981, 6619547, 6736320, 7392933, 7014113, 7240831, 7353999,
7519239, 7204417, 6942152, 7070091, 7097099, 7621453
The Code Reader software uses the Mozilla SpiderMonkey JavaScript engine, which is distributed under the terms of the
Mozilla Public License Version 1.1.
The Code Reader software is based in part on the work of the Independent JPEG Group.
Code Corporation, 14870 South Pony Express Road, Suite 200, Bluffdale, UT 84065
www.codecorp.com

C005905_01_CR1000_User_Manual
Table of Contents
1.0 - Unpacking.....................................................................................................................................................1
2.0 - Powering the Reader On/Off .......................................................................................................................1
3.0 - Detaching a Cable ........................................................................................................................................1
4.0 - Reading Range .............................................................................................................................................2
5.0 - Targeting and Optimal Reading Distance ..................................................................................................2
6.0 - Reader Feedback..........................................................................................................................................3
7.0 - Symbologies Defaulted On..........................................................................................................................4
8.0 - Symbologies Defaulted Off .........................................................................................................................4
9.0 - Reader ID & Firmware Version....................................................................................................................5
10.0 - Hole Mounting Pattern...............................................................................................................................6
11.0 - CR1000 Overall Dimensions......................................................................................................................6
12.0 - Maintenance................................................................................................................................................7
13.0 - Warranty......................................................................................................................................................7

C005905_01_CR1000_User_Manual
2.0 - Powering On/Off the Reader
1.0 - Unpacking
Remove the CR1000 from its packing and inspect it for damage. If the reader was damaged during shipping, please call
Code at (801) 495-2200.
The CR1000 is shipped with one of the following cables attached:
6’ USB
Straight Cable
8’ RS232 Coiled Cable
w/ Power Supply
For USB: to power up the reader, simply plug the USB cable provided into the reader and USB port on the host device.
After several seconds, the unit will beep twice, the LED will turn off and the CR1000 is ready for use.
For RS232: to power up the reader, simply plug the RS232 cable provided into the reader, plug the Power Supply into
the AC outlet, plug the power supply cord into the barrel jack on the cable, and lastly connect the cable to the appropriate
serial port on the host device.
After several seconds, the unit will beep twice, the LED will turn off and the CR1000 is ready for use.
To detach a cable, press a paper clip into the hole on the back of the CR1000, and gently pull the cable from the reader.
3.0 - Detaching a Cable
1

C005905_01_CR1000_User_Manual
4.0 - Reading Ranges
CR1000 Performance
Test Code Min Inches (mm) Max Inches (mm)
3 mil Code 39 3.9” (100 mm) 5.0” (125 mm)
7.5 mil Code 39 2.2” (55 mm) 8.0” (205 mm)
13 mil UPC 2.0” (50 mm) 10.8” (275 mm)
4.2 mil Data Matrix 3.7” (95 mm) 4.7” (120 mm)
5 mil Data Matrix 3.7” (95 mm) 5.5” (140 mm)
6.3 mil Data Matrix 3.1” (80 mm) 6.3” (160 mm)
10 mil Data Matrix 1.6” (40 mm) 7.9” (200 mm)
20.8 mil Data Matrix 1.6” (40 mm) 12.2” (310 mm)
Note: working ranges are a combinaon of both the wide and high density elds. All samples were high quality codes
and were read along a physical center line at a 10° angle. Default AGC sengs were used. Accuracy= +/- 10%.
5.0 - Targeting & Reading Distance
The blue bars are used for aiming, center the bars in the center of a bar code and press the LED button to scan. The
optimal reading distance is approximately 4.0” (10 cm).
2

C005905_01_CR1000_User_Manual
Scenario Top LED Button
CR1000
Successfully
Powers Up
CR1000
Successfully
Enumerates with
Host (via cable)
Attempting to
Decode
Successful
Decode and Data
Transfer via Cable
Conguration
Code Successfully
Decoded and
Processed
Conguration
Code Successfully
Decoded
but wasn’t
Successfully
Processed
Sound
Green LED lights Up 1 Beep
Once enumerated, the
Green LED turns off
1 Beep
Press the top button
Green LED light is off
Press the top button
the LED does not ash
Press the top button
the LED does not ash
None
Green LED lights Up 1 Beep
2 Beeps
4 Beeps
6.0 - Reader Feedback
3

C005905_01_CR1000_User_Manual
7.0 - Symbologies Defaulted On
Aztec
Codabar
Codabar
Code 39
Code 39 Disable Checksum
Code 39 Short Margin
Code 93
Code 128
Code 128 Short Margin
Data Matrix
All GS1 DataBar
Interleaved 2 of 5
MSI Plessy
NEC 2 of 5
PDF417
Telepen
UPC
UPC Short Margin
UPC Extension
8.0 - Symbologies Defaulted Off
Codablock F
Code 11
Code 39 Extended Full ASCII
Composite
Data Matrix Rectangle
Data Matrix Inverse
Interleaved 2 of 5, 2 Digits
Macro PDF417
Maxicode
Matrix 2 of 5
Micro PDF417
OCR
Postal Codes - All Postal Codes
QR Code
The following are symbologies that have a default of ON. To turn symbologies on or off, scan the symbology bar codes
located in the CR1000 Conguration Guide located on our website at http://www.codecorp.com.
The following are symbologies that have a default of OFF. To turn symbologies on or off, scan the symbology bar codes
located in the CR1000 Conguration Guide located on our website at http://www.codecorp.com.
4

C005905_01_CR1000_User_Manual
9.0 - Reader ID and Firmware Version
To nd out the Reader ID and rmware version, open a text editor program (i.e., Notepad, Microsoft Word, etc.) and
read the following code:
You will see a text string indicating your rmware version and CR1000 ID number (see below):
Xap/i - Code Internal ID (not applicable)
VVVV is the application rmware version number
WWWW is the Core rmware version number
XXXX is not applicable
SSSSSSSSSS Reader’s serial number (ten digits)
P is “A” if running rmware is the application
XXX-XX+XX - Internal ID (not applicable)
Example:
Xap/i3000300006040010002363A06D-SD+SQ
Note: Code will periodically release new rmware for CR1000 readers. For information on latest rmware versions,
call Code at (801) 495-2200. To upgrade rmware, please visit our website at
http://www.codecorp.com/codesupport.php and follow instructions provided.
Reader ID and Firmware
Xap/iVVVVWWWWXXXXSSSSSSSSSSPXX-XX+XXX
5

C005905_01_CR1000_User_Manual
10.0 - CR1000 Hole Mounting Pattern
11.0 - CR1000 Overall Dimensions
NOTE 1:
LOCATING HOLES ARE 2MM IN DIAMETER, HOLE DEPTH is 1.5 MM
NOTE 2:
MOUNTING INSERTS ARE M3-.5 INTERNAL THREAD, 3.8MM LENGTH
6
Other manuals for CR1000
4
Table of contents
Other Code Barcode Reader manuals

Code
Code CR2 User manual

Code
Code Code Reader 1000 User manual

Code
Code CR7000 Series User manual

Code
Code CORTEXJPOS CR2300 User manual

Code
Code Code Reader CR3500 User manual

Code
Code Code Reader 3.0 User manual

Code
Code CR2 User manual

Code
Code Code Reader 2.0 Operating instructions

Code
Code CR1200 User manual

Code
Code 2600 Quick setup guide

Code
Code CR900FD User manual

Code
Code CR950 User manual

Code
Code CORTEXJPOS CR6000 User manual

Code
Code CR900FD User manual

Code
Code Code Reader 3600 User manual

Code
Code Reader 1200 User manual

Code
Code CR1400 User manual

Code
Code Code Reader 2.0 User manual

Code
Code 2600 Quick setup guide

Code
Code CR900FD User manual