Clements SUC 81030 User manual

Ceevac
High Vacuum High Flow
Portable Suction Pump
SUC 81030
12 VDC 100-240 V~ 50/60 Hz
User Manual
CLEMENTS
Manual No. SUC 81030 008
Issue 2

User Manual
Ceevac High Suction Pump
Manual Number SUC 81030 008 Issue 2 2021 02
Copyright © 2021 ICU Medical Australia Pty Ltd
The information in this manual was originated by, and is the exclusive
property of ICU Medical Australia Pty Ltd. It is furnished for customer
information only, and is not an authorisation or licence to make this
product or to furnish this information to others.
Safety
Thank you for purchasing this Clements Ceevac High
Suction Pump.
For your safety it is imperative that this unit only be
operated by authorised personnel in accordance with the
instructions as described in this manual. Operated in this
way, the Ceevac High Suction Pump will provide the
standard of service specified.
Due to continual improvements in product design, the
Ceevac High Suction Pump may vary in detail from the
descriptions in this manual. In the event of further
questions please contact your local distributor or ICU
Medical Australia direct.
Familiarise yourself with these Directions for Use
before operating this device.
Sponsor:
ICU Medical Australia Pty Ltd
Unit U, 10 16 South St
Rydalmere NSW 2116 Australia
Phone: +61 2 9466 5300
Website: www.clements.net.au
CA MI srl
Via Ugo La Malfa 13
Frazione Pilastro
43013 Langhirano (PR)
Italy
0123

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
3
Contents
Description......................................................................... 4
Specifications .................................................................... 5
Environmental Conditions .................................................. 6
Symbols. ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ... 7
Cautions ........ ..... ...... ..... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... 9
Controls and Operation.... ...... ..... ..... ..... ..... ...... ..... ..... ..... ... 10
sing FLOVAC Disposable Liners ..................................... 11
Battery Status and Charging .............................................. 13
Cleaning .......... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ... 15
Spare Parts........................................................................ 17
Troubleshooting ......... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ... 18
Wiring Diagram..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ... 19
Diagnostic Setup...... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... 20
Return for Repair . ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... .... 20
Periodic Safety Check.... ..... ...... ..... ..... ..... ...... ..... ..... ..... ..... 22
Emissions Guidance Table ................................................ 23
Immunity Guidance Table .................................................. 24
Immunity Guidance Table .................................................. 25
Separation Guidance Table .............................................. 26
Warranty .......................................................................... 30

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
4 Description
Description
The Clements Ceevac High Suction Pump is a compact, portable unit
designed to suit the needs of hospitals, doctors’ surgeries and
paramedics in providing a strong source of suction for use in both
indoor and outdoor environments where mains power is unavailable
or interrupted.
Identification
SUC 81030 Ceevac High Vacuum / High Flow Portable Suction Pump
Intended Use
To provide a continuous vacuum source, within the stated operating
vacuum range, for the aspiration of fluids and particulate matter in
medical procedures carried out by clinically trained and authorized
personnel.
Contraindications
Before using the Ceevac, consult the instructions for use. Failure to
follow instructions in this manual could cause harm.
Do not use Ceevac for thoracic or low vacuum drainage.
Do not use Ceevac for suctioning of explosive, corrosive or easily
flammable fluids.
Ceevac is not suitable for MRI. Do not place the Ceevac pump in MRI
environments.
Classifications
GMDN 63642
GMDN Term Surgical suction um
GMDN Synonym As irator
Device Class Class IIa (Rule 11)
Electrical Protection (on battery) Internally owered
Protection Ty e BF A lied Part
Sterilisation Not su lied in sterile state
Anaesthetic Rating
NOT Category AP
NOT Category APG
O eration Mode Continuous o eration
Electrical Protection (on vehicle) Class II
Electrical Protection (on mains) Class II

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
5
Specifications
Specifications
Maximum Vacuum -80 kPa [-600 mmHg]
Maximum Flow 21 L/min (through jar) 32 L/min (free air)
Mains Power
Requirement
100 - 240 V~ 50/60 Hz 110 VA
Internal Battery Fully sealed, rechargeable, lead acid battery.
12 V 4.0 Ah ca acity
Battery Run Time Total 60 minutes unoccluded
Charge / Status
Indicator
Light Emitting Diode (LED) lam on control anel
Red / Green / Amber Off / Steady / Flashing
Audible bee when LED is red.
Warning time Minimum 5 minutes
Power Pack /
Battery Charge
External; Powers um . Monitors and charges
battery when mains ower su ly is connected
Pum Piston ty e
Filter Dis osable hydro hobic and bacterial filter
BFE 99.9999%, VFE 0.027 micron
Collection Container 1 litre autoclavable, shatter roof lastic jar
O tional 1 litre dis osable liner jar
Overfill Protection Float valve mechanism
Vacuum Control Needle valve
Gauge Bourdon tube ty e. Dual scale. Accuracy ±5%
Gauge Range 0 to -100 kPa graduated at 5 kPa
0 to -760 mmHg graduated at 50 mmHg
Weight 4.0 kg
Dimensions 360L x 215W x 195H mm
Standard Conditions 25C, Sea level, 100 kPa
Vehicle Power
Requirement
12Vdc 4A

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
6 Environmental Conditions
Package Contents
The Clements Ceevac package contains:
• Ceevac portable suction pump
• Charger with mains power supply lead
• Silicone 8 x 14 mm medical suction tubing; 18cm x2, 150cm x1
• 1 litre reusable collection jar with lid assembly
• Cigarette lighter 12 volt power lead
• Disposable antibacterial/hydrophobic filter
• Stepped conical tubing connector
Environmental Conditions
Environmental conditions for operation, transportation and storage
are shown in the following table. In addition, for vehicular
transportation, the unit should be kept upright.
State Parameter Minimum Maximum
O erating Tem erature 5ºC 35ºC
Humidity 10% RH 93% RH
Barometric Pressure 700 hPa 1060 hPa
Tem erature -25ºC 70ºC
Humidity 0% RH 93% RH
Barometric Pressure 500 hPa 1060 hPa
Trans ort and Storage
Shipping with Internal SLA Battery
• Unrestricted USA shipment.
• Complies with IATA/ICAO Special Provision A67 for air transport.
• Recognised by DOT as “Dry Charge” 49 CFR 171 189 for surface
transport.
• Classified per MG Amendment 27 as a non hazardous material
for water transport.
Jar Classifications
GMDN 44943
GMDN Term Suction System Canister, Reusable
Device Class Class I (Rule 1)
Sterilisation Not su lied in sterile state

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
7
Symbols
Symbols
0123
General warning
Consult user manual
Ty e BF A lied Part (suction cannula)
Insulation Class II (double insulation)
Hz Mains ower frequency
Direct current
Battery
On / Off
CE Mark in conformity with CE MEDDEV directive
93/42/CEE and subsequent changes
Manufacturer
REF Model / Reference Number
E24
Ty e a roval E24 R10-060907 according to ECE R10
Automotive EMC Test
~Alternating current

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
8
LOT Lot / Batch Number
SN Serial Number
Fragile
Relative Humidity
Tem erature Range
Atmos heric Pressure Range
C-Tick Mark
Degree of rotection against intrusion by body arts or
objects an against ingress by water.
1st Digit - Penetration of Solids
2 = Protected against solids > Ø 12.5 mm
2nd Digit - Penetration of Liquids
1 = Protected vertical dri ing water
IP21
Kee Cool / Kee out of direct sunlight
Dis ose of electrical roduct according to requirements
of WEEE directive
Symbols

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
9
Cautions
Usage
1. Use only for the specified Intended Use.
2. Do not use near flammable substances such as oxygen or
anaesthetic gases.
3. Home care use is restricted to home carers and physically and
mentally competent adults.
4. In home care use, keep accessories out of reach of infants as
small parts can present a choking hazard.
Fluids
1. Keep device clear of water and other fluids. Do not handle pump
with wet hands.
Electrical
1. Use only the supplied power pack / charger.
2. Confirm that electrical rating of power pack matches that of the
mains power. Avoid the use of power boards and extensions.
3. If power pack / charger is used, maintain clear access to the
mains power outlet to facilitate disconnection.
4. Place pump clear of patient and other electronic equipment.
5. When not in use, disconnect power pack from power supply.
6. Do not pull cable to remove plug from mains power outlet.
General
1. Check the pump and fittings for damage before each use.
2. Do not use without the bacteria/hydrophobic filter correctly
fitted.
3. Switch off pump immediately if overflow float valve is actuated.
4. After use, clean and store away from heat, dust and sunlight.
Cautions

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
10
Operation
1. Place the pump on a flat stable horizontal surface.
2. Connect a short length of silicone tubing from the jar “VACUUM”
port to the “IN” (or directional arrow symbol) side of the
bacterial/hydrophobic filter. Connect a short length of silicone
tubing from the other side of the filter to the pump inlet.
3. Connect the long silicone tubing to the jar “PATIENT” port.
4. Select power source.
1) Connect plug of supplied power pack / charger to power
socket at rear of pump. OR
2) Connect plug of supplied cigarette lighter lead to power
socket at rear of pump. OR
3) Use internal battery.
Controls and Operation
Pump Controls
Vacuum Control
Status LED
Bacterial / Hydro hobic Filter
» Must ALWAYS be fitted «
“IN” or Δ Side
of Filter
“VACUUM” ort
(above float valve)
Push ON /
Push OFF
Switch
Vacuum Gauge
kPa / mmHg
“PATIENT” Port
Connect Patient
Tubing
Power Inlet
(at rear)
Table of contents
Other Clements Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual