Clearfield YOURx-Aerial User manual

YOURx-Aerial Terminal
Installation Manual ______________________________________________________
Manual 019588 REV B - Sept 2018

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
2
YOURx-Aerial Terminal
Installation Manual _________________________________________________________
Manual 019588 REV B - Sept 2018
Table of Contents
Application 3
Description 3
Technical Specications 3
Components 4
Parts List 5
Recommended Tools 6
Strand Mounting 7
Accessing the YOURx-Aerial Terminal 8
Preparing FlexPorts for Drops 9
Installing Microduct and Push/Pull Fiber Drops 10
Installing FLATdrop and D-ROP with FlexConnector 11
Installing FlexPorts in the Field 12
Installing the Field Installable FlexConnector 13
Preparing End Plates for Splicing 15
Preparing Fiber Cables for Splicing 16
Splicing in the YOURx-Aerial Terminal 18
Splice Tray Setup 18
Ribbon 19
Loose Tube 21
6 Fiber 900 Micron Assembly 23
Drop Cable Options 24
Connector Cleaning Procedure 25
Standard Warranty 28
Proprietary Notice 29
Technical Support 29

3
YOURx-Aerial Terminal
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019588 REV B - Sept 2018
Application
Description
Technical Specications
When the network deployment plan calls out for an aerial
application, Cleareld’s YOURx-Aerial Terminal application
allows for the exibility to terminate a feeder ber, directly
into revenue generating drops and has the capability to
accommodate a ber cable mid-span, allowing cables to
be fully utilized while feeding multiple terminals and access
points.
Designed with many of the same features as the YOURx-Terminal,
the YOURx-Aerial Terminal allows for aerial or strand mount ber
deployment within the network architecture.
The YOURx-Aerial Terminal can accept the “hand-off” of ber and distribute up to 24 individual service drops and has the
capability to mid-span a larger count ber cable, allowing the service provider to deploy multiple terminal/access points
along the same cable run, maximizing the investment in ber deployment.
Designed for easy, craft accessibility, the YOURx-Aerial Terminal application has an upward hinging, kickstand supported
cover with four side entrance cable access ports. Two individual compartments separate the incoming splices from the drop
ports for network security. The backplane of the unit has the capacity to hold up to three splice trays, incorporating ber
management and bend-radius protection into the design. Each splice tray supports 24 loose tube or 72 ribbon splices. With
up to 24 individual drops terminated to SC of LC connectors, the YOURx-Aerial Terminal can accept all of the FieldShield®
drop options, as well as other cable drop options.
YOURx-Aerial Terminal - Patch and Splice
Dimensions 14.80” W x 11.61” H x 8.15” D (height includes strand bracket)
Material Black UV resistant Thermoplastic
Mounting Options Aerial or Strand Mount
Internal Slack Storage Up to 8 feet of ribbon (144 ber); up to 8 feet of loose tube (144 ber)
Feeder Ports Four silicone sealed ports on ends of unit; two on each end
Distribution Ports Up to 24 - 10 mm YOURx FlexPorts that accept FieldShield® Microduct or FLEXdrop connectors
Connector Types SC/APC, SC/UPC, LC/APC, LC/UPC
Splicing Capabilities 24 loose tube or 72 ribbon splices per tray; three splice trays per terminal

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
4
YOURx-Aerial Terminal
Installation Manual _________________________________________________________
Manual 019588 REV B - Sept 2018
Street Side View
Field Side View
24 Distribution
FlexPorts
12 each per side
Adapter Plate(s)
w/ Connectors
(SC or LC)
Top row open for future use
2nd row for ports 1-12
3rd row for ports 13-24
Fiber Drop
Management
Rings
Splice Tray
Area
Up to 3 Splice
Trays
Slack Management
Rings
Loose tube Slack
Basket variant not shown
Cable Clamp
Locations
2 each per side
Slack Capacity:
• 8FT Loose Tube, max 144 bers
• 8FT Ribbon, max 144 bers
• Mid-Span Capable
GROUNDING AND BONDING: PER LOCAL PRACTICE
Components
Lid Kickstand
Strength Member
Clamps
2 each per side
Lid Kickstand

5
YOURx-Aerial Terminal
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019588 REV B - Sept 2018
24
10
1 3
5
1. Hose Clamps (2)
2. Bug Nuts (2)
3. Ribbon Strain Relief (3 per Splice Tray)
4. Ribbon Splice Chip (2 per Splice Tray)
5. Splice Chip (2 per Splice Tray)
6. Half Grommets (8)
7. Splice Tray (up to 3)
8. End Plates (2)
Optional Accessories
9. FlexPorts
10. Field Installabe FlexConnectors
Parts List
7
6
9
8

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
6
YOURx-Aerial Terminal
Installation Manual _________________________________________________________
Manual 019588 REV B - Sept 2018
Recommended Tools
Tool Image
Mid-Span Access Tool
De-burring Tool
Snips
Pliers
Optical End Face
Cleaning kit
Small Cable Ties
Cable Opening
Tools
Can Wrench

7
YOURx-Aerial Terminal
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019588 REV B - Sept 2018
Strand Mounting
Mounting YOURx-Aerial Terminal to strand options:
A: Using provided mounting brackets and bug nuts
B: Using optional adjustable mounting bracket
A: Provided Mounting Bracket B: Optional Bracket
P/N: 019448

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
8
YOURx-Aerial Terminal
Installation Manual _________________________________________________________
Manual 019588 REV B - Sept 2018
Accessing the YOURx-Aerial Terminal
The lid on each side of the YOURx-Aerial Terminal can be propped open with the attached kickstand. Push the kickstand
back and seat it under the tabs on the inside of the lid to prevent the lid from closing while the terminal is in use.
Each side of the YOURx-Aerial Terminal has a lid which is secured by two tabs. Release the tabs on one side in order to
open the lid on that side. Close the lid and snap the tabs into place to secure it back in place.

9
YOURx-Aerial Terminal
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019588 REV B - Sept 2018
Preparing FlexPorts for Drops
Step 1: Using pliers, remove the tab from the
desired port by bending and breaking the excess
plastic away.
Step 2: De-burr (using a de-burring tool/snips/
knife) the port hole for a smooth transition, helping
to prevent damage to the ber when it enters the
port.
Supports all FieldShield Drop Options
The terminal is available in a 6, 12 or 24 port drop
conguration.
• Ports 1-12 will be on the left end plate, typically
closest to the serving pole (unless specied
differently, at ordering).
• Ports 13-24 on far end endplate
Useable FlexPorts will be marked with a silver “X”
on the inside of port tab, indicating that a FlexPort
has been installed and capable of accepting a
water tight FlexConnector or microduct.
End Plate Interior End Plate Exterior

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
10
YOURx-Aerial Terminal
Installation Manual _________________________________________________________
Manual 019588 REV B - Sept 2018
Installing Microduct and Push/Pull Fiber Drops
Step 2: Insert the pull string, if one is being utilized, through
the FlexPort, and rmly seat the microduct into the FlexPort.
Step 3: Tie the pull string to the bulkhead until you are ready to
pull in a ber drop.
Step 1: De-burr the microduct, using the de-burring tool or similar device (snips or cable knife), creating a cone shape on
the inside of the microduct for a smooth transition.
Step 4: After pulling ber into terminal, complete the
“Pushable Connector” housing as instructed with the specic
connector being utilized.
Step 5: Inspect Then Connect! Follow our recommended
Connector Cleaning Procedures included in this manual for a
reliable connection.
Step 6: Make the connection to the assigned port.
Step 7: Route slack around ber drop management rings.