Clarke YDH30 Instruction Manual

OPERATION & MAINTENANCE
INSTRUCTIONS
LS0916
30 LITRE DEHUMIDIFIER
MODEL NO: YDH30
PART NO: 6479600

2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
INTRODUCTION
Thank you for purchasing this CLARKE product.
Before attempting to use this product, please read this manual thoroughly and
follow the instructions carefully. In doing so you will ensure the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission.
This guarantee does not effect your statutory rights.
ENVIRONMENTAL PROTECTION
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
R134a is a refrigerant that complies with EEC environmental standards;
nonetheless, the refrigerant circuit on the machine should not be punctured.
At the end of its working life, consign the air conditioning unit to a special
collection centre.

3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
SAFETY WARNINGS
1. Please read these instructions carefully and retain for future reference.
2. Position the mains cable so that it cannot be inadvertently pulled or
pinched and where it does not cause a trip hazard.
3. This appliance is designed to dehumidify residential environments and must
not be used for any other purposes.
4. If the appliance requires repair, always contact your CLARKE dealer.
Always insist on original spare parts. Repairs carried out by unauthorized
persons may be dangerous and invalidate the guarantee.
5. Do not use extension power cables.
6. Before cleaning or maintenance operations, always unplug the appliance
from the power supply.
7. Do not move the appliance by pulling the power cable.
8. Do not install the appliance in rooms containing gas, oil or sulphur. Do not
install near sources of heat.
9. Do not use the appliance on inclined surfaces.
10. Keep the appliance at least 50 cm away from curtains, inflammable
substances (alcohol etc) or pressurised containers (e.g. aerosol cans).
11. Do not rest heavy or hot objects on top of the appliance.
12. Always transport the appliance upright or resting on one side. Remember
to drain the tank before moving the appliance.
13. Wait at least 1 hour after transporting the appliance before using it to allow
the refrigerant gasses to settle.
14. Do not use the appliance outdoors.
15. Do not obstruct the air inlet or outlet.
16. Take care when handling water near electrical appliances.
17. Make sure that the air inlets/outlets are not covered and that the filers are
in place.
WARNING: IF THE SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY
THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED
PERSONS IN ORDER TO AVOID A HAZARD.

4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
ELECTRICAL CONNECTIONS
Before switching the product on, make sure that the voltage of your electricity supply is
the same as that indicated on the rating plate. This product is designed to operate on
230VAC 50Hz. Connecting it to any other power source may cause damage.
This product may be fitted with a non-rewireable plug. If it is necessary to change the
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or
damaged, the plug must not be used until a suitable replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or due to
damage, it should be cut off and a replacement fitted, following the wiring instructions
shown below. The old plug must be disposed of safely, as insertion into a mains socket
could cause an electrical hazard.
If the colours of the wires in the power cable of this product do not correspond with the
markings on the terminals of your plug, proceed as follows.
• The wire which is coloured Blue must be connected to the terminal which is
marked Nor coloured Black.
• The wire which is coloured Brown must be connected to the terminal which is
marked Lor coloured Red.
• The wire which is coloured Yellow and Green must be connected to the terminal
which is marked E or or coloured Green.
We strongly recommend that this machine is connected to the mains supply via a Residual
Current Device (RCD)
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS
SUPPLY.
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH
Plug must be BS1363/A approved.
Always fit a 5 Amp fuse.
Ensure that the outer sheath of the cable is firmly held by the clamp
Neutral
(Blue)
Live
(Brown)
Earth
(Green and Yellow)

5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
BEFORE USE
LOCATING THE DEHUMIDIFIER
• Position the dehumidifier
close to a mains supply
socket.
• Free space as shown must
be left around the
dehumidifier, so as not to
block the air flow.
• Make sure that the power
cable is not placed where it
can be inadvertently pulled
or pinched and where it
does not cause a trip
hazard.
• Do not place the dehumidifier next to a radiator or other heat source as
this will reduce the performance of your dehumidifier.
• To maximise efficiency, do not open any doors or windows during use.
• Wait at least 1 hour after transporting the appliance before
using it to allow the refrigerant gasses to settle.
DISPLAY SCREEN

6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
CONTROL PANEL
TO CHANGE THE DISPLAY UNITS FROM °F TO °C.
Press the Humidity and Timer buttons at the same time.
Used to adjust
the humidity
setting from 40%
- 70% (default
50%).
Turns the
dehumidifier on
or off.
Set the number
of hours until the
dehumidifier is
turned on or off.
Selects the
operating mode
also activates
the child lock.
Starts or stops
the swing
function.
Ultra quiet fan
mode, ideal for
overnight use.
Activate the
ionizer function.
Activate the
internal drying
function.

7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
OPERATION
SWITCHING ON/OFF
1. Plug into the mains supply socket
and switch on.
• The dehumidifier will begin and
the display will show the current
humidity level and temperature
of the room.
2. Press the POWER button to switch
the dehumidifier ON.
• The dehumidifier will run in the
last mode selected.
3. Press the POWER button again to switch the dehumidifier OFF.
CHILD LOCK
The child lock is used to disable the function keys, to prevent accidentally
changing the settings.
TURNING ON
1. Press and hold the MODE button for 2 seconds to turn
the child lock on.
• The child lock symbol will be shown in the display.
TURNING OFF
• Press and hold the MODE button for 2 seconds to turn the child lock off.

8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
TIMER
TIMER-ON SETTING (AUTO START)
1. While the dehumidifier is NOT
running: Press TIMER key
repeatedly to set the length of
time (1-24 hours) until the
dehumidifier turns on.
• The display will show the
selected number of hours
flashing on and off for 5
seconds and then stop flashing.
2. To cancel the timer function press the TIMER key once more.
TIMER-OFF SETTING (AUTO STOP)
1. While the dehumidifier is running:
Press TIMER key repeatedly to set
the length of time (1-24 hours) until
the dehumidifier turns off.
• The display will show the
selected number of hours
flashing on and off for 5
seconds and then stop flashing.
2. To cancel the timer function press
the TIMER key once more.

9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
MODE SELECTION
Press the MODE key to cycle through
the modes:
Auto
Dehumidification
Press the humidity button repeatedly to select the
required humidity level.
• The humidity level can be set between 40%
and 70% (5% increments) and set to 50% as
default.
• The dehumidifier turns on or off if the humidity
goes above or below that level.
High
Dehumidification
The dehumidifier will run continuously at high
speed regardless of the current humidity level.
Mild
Dehumidification
The dehumidifier will run continuously at low
speed regardless of the current humidity level.
Air Purification The dehumidifier function is switched off and the
fan will run continuously through the filter.
• Fit the filter (See page 10) before using this
mode.
• Press the humidity button to change the fan
speed from high to low.
Ventilation The dehumidifier function is switched off and the
fan will run continuously.
• Remove the HEPA filter (See page 10) before
using this mode.
• Press the humidity button to change the fan
speed from high to low.

10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
IONIZER FUNCTION
The air ionizer function is used to remove particles from the air.
Airborne particles are attracted to the electrode within the dehumidifier in an
effect similar to static electricity, this also kills some bacteria.
TO ACTIVE THE IONIZER FUNCTION,
1. Press the 'IONIZER" button.,
• A 'leaf" symbol will appear on the display to show
the ionizer function is active.
• The swing function can also be used to adjust the
position of air outlet grill.
FITTING/ REMOVING THE FILTER
1. Remove the front panel.
2. Remove the plastic filter.
3. Insert the filter into the framework.
• Make sure that the front of the
filter is facing towards you.
• An optional HEPA filter (not
supplied) is available from your
Clarke dealer.
4. Replace the plastic filter making
sure that all the lugs are seated
correctly.
Table of contents
Other Clarke Dehumidifier manuals

Clarke
Clarke DH10 Instruction Manual

Clarke
Clarke DH10L Instruction Manual

Clarke
Clarke YDE20 Manual

Clarke
Clarke DH20 Instruction Manual

Clarke
Clarke DH30L Instruction Manual

Clarke
Clarke CONTRACTOR IDH70L Instruction Manual

Clarke
Clarke CD1250 User manual

Clarke
Clarke Air CD1155 User manual

Clarke
Clarke DH20L Instruction Manual

Clarke
Clarke CONTRACTOR IDH50L Instruction Manual