Cisco Meraki MR46 User manual

MR46 nstallation Guide
The Cisco Meraki MR46 are dual-band enterprise class 802.11ax cloud-managed access points. Designed for highest
capacity and highest density, the MR46 meets the needs of the most demanding environments. The access point also
includes a third radio dedicated to optimizing the RF environment and securing the airwaves.
About this Guide
This guide provides instruction on how to install and configure your MR46 access points. This guide also provides
mounting instructions and limited troubleshooting procedures. For more wireless installation guides, refer to the wireless
installation guides section on our documentation website.
Product Overview
Physical Specifications
MR46
Interfaces
• 1x 1000/2.5G BASE-T Ethernet (RJ45)
• 1x DC power connector (5.5 mm x 2.5 mm, center positive)
Power
• Power over Ethernet: 42.5 - 57 V (802.at compliant)
•Alternative: 12 V DC input
•Power consumption: 18W max (802.3at)
•Power over Ethernet injector and DC adapter sold separately
Environment
1

• Operating temperature: 32 °F to 104 °F (0 °C to 40 °C)
• Humidity: 5 to 95% non-condensing
Physical Security
• Two security screw options (included) (13.5 mm long and 2.5
mm diameter and 5 mm head)
• Kensington lock hard point
• Concealed mount plate with anti-tamper cable bay
Product View and Physical Features
Your MR46 has the following features:
2

The mount cradle has the following features:
3

Security Features
The MR46 features multiple options for physically securing the access point after installation:
1. Security screw – The accessory kit includes screws that can be used to secure the access point to the mount
cradle. Engaging the security screw prevents accidental dislodging and theft.
2. Kensington lock – The access point contains a hard point that allows it to be secured to any nearby permanent
structure using a standard Kensington lock.
Ethernet Ports
The MR46 features a Gigabit Ethernet RJ45 port that accepts 802.3af power (labeled “Eth0, PoE”). This port should be
used for uplink to your WAN connection.
The port labeled “PoE” accepts 802.3at and 802.3af power and should be used as the primary uplink to your LAN/
WAN.
Power Source Options
The MR46 access point can be powered using either the Meraki AC Adapter, PoE njector (both sold separately), or a
third-party PoE switch.
Factory Reset Button
f the button is pressed and held for at least five seconds and then released, the AP will reboot and be restored to its
original factory settings by deleting all configuration information stored on the unit.
LED Indicators and Run Dark Mode
Your access point is equipped with a multi-color LED light on the front of the unit to convey information about system
functionality and performance:
• Orange - AP is booting (permanent Orange suggests hardware issue)
• Rainbow - AP is initializing/scanning
• Blinking Blue - AP is upgrading
• Green - AP in Gateway mode with no clients
4

• Blue - AP in Gateway mode with clients
• Blinking Orange - AP can't find uplink
NOTE: Blinking Green LED indicates that the device is in site survey mode. Please see the Conducting Site Surveys
with MR Access Points for more details.
The MR46 access point may be operated in “Run Dark” mode for additional security and to reduce the visibility of the
access point. n this mode, the LED will not be illuminated. This mode may be enabled through Meraki Dashboard.
Package Contents
The access point packages contain the following:
MR46 Cloud-Managed Access Point
Mount cradle including built-in level tool
Drop ceiling mount kit
5

Wall screws, wall screw anchors, and security screws
Safety and Warnings
These operations are to be taken with respect to all local laws. Please take the following into consideration for safe
operation:
• Power off the unit before you begin. Read the installation instructions before connecting the system to the power
source.
• Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with
standard practices for preventing accidents.
6

• Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to
follow the correct procedures could result in a hazardous situation to people and damage to the system.
• This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective
device is rated not greater than: 15 A, 125 Vac, or 10A, 240 Vac.
• Please only power the device with the provided power cables or standard PoE to ensure regulatory compliance.
Pre-install Preparation
You should complete the following steps before going on-site to perform an installation.
Configure your Dashboard Network
The following is a brief overview only of the steps required to add an access point to your network. For detailed
instructions about creating, configuring and managing Meraki wireless networks, refer to the online documentation
(documentation.meraki.com).
1. Login to http://dashboard.meraki.com. f this is your first time, create a new account.
2. Find the network to which you plan to add your APs or create a new network.
3. Add your APs to your network. You will need your Meraki order number (found on your invoice) or the serial
number of each AP, which looks like Qxxx-xxxx-xxxx, and is found on the bottom of the unit. You will also need
your Enterprise license key, which you should have received via email.
4. Go to the map / floor plan view and place each AP on the map by clicking and dragging it to the location where you
plan to mount it.
Check and Set Firmware
To ensure your access point performs optimally immediately following installation, it is recommended that you facilitate a
firmware upgrade prior to mounting your AP.
1. Attach your AP to power and a wired nternet connection. See the "Power the Ap" section for details.
2. The AP will turn on and the LED will glow solid orange. f the unit does not require a firmware upgrade, the LED
will turn either green (no clients associated) or blue (clients associated) within thirty seconds.
* f the unit requires an upgrade, the LED will begin blinking orange until the upgrade is complete, at which point the LED
will turn solid green or blue. You should allow at least a few minutes for the firmware upgrade to complete, depending on
the speed of your internet connection.
Check and Configure Upstream Firewall Settings
f a firewall is in place, it must allow outgoing connections on particular ports to particular P addresses. The most
current list of outbound ports and P addresses for your particular organization can be found on the firewall configuration
page in your dashboard.
7

Assigning an P Address
All gateway A (An AP with Ethernet connections to the LAN) must be assigned routable P addresses. These P
addresses can be dynamically assigned via DHCP or statically assigned.
Dynamic Assignment
• When using DHCP, the DHCP server should be configured to assign a static P address for each MAC address
belonging to a Meraki AP. Other features of the wireless network, such as 802.1X authentication, may rely on the
property that the APs have static P addresses.
Static Assignment
• Static Ps are assigned using the local web server on each AP. The following procedure describes how to set the
static P:
• Using a client machine (e.g., a laptop), connect to the AP wirelessly (by associating to any SS D broadcast by the
AP) or over a wired connection.
• f using a wired connection, connect the client machine to the AP either through a PoE switch or a PoE njector. f
using a PoE switch, plug an Ethernet cable into the AP’s Ethernet jack, and the other end into a PoE switch. Then
connect the client machine over Ethernet cable to the PoE switch. f using a PoE njector, connect the AP to the
“PoE” port of the njector, and the client machine to the “LAN” port.
• Using a web browser on the client machine, access the AP’s built-in web server by browsing
to http://my.meraki.com. Alternatively, browse to http://10.128.128.128.
• Click on the “Uplink Configuration” tab. Log in. The default login is the serial number (e.g. Qxxx-xxxx-xxxx), with no
password (e.g., Q2DD-551C-ZYW3).
• Configure the static P address, net mask, gateway P address and DNS servers that this AP will use on its wired
connection.
• f necessary, reconnect the AP to the LAN.
Static IP via DHCP Reservations
• nstead of associating to each Meraki AP individually to configure static P addresses, an administrator can assign
static P addresses on the upstream DHCP server. Through “DHCP reservations,” P addresses are “reserved” for
the MAC addresses of the Meraki APs. Please consult the documentation for the DHCP server to configure DHCP
reservations.
Collect Tools
You will need the following tools to perform an installation:
8

Collect Additional Hardware for nstallation
You will need the following hardware to perform an installation:
nstallation nstructions
Choose Your Mounting Location
A good mounting location is important to getting the best performance out of your access point. Keep the following in
mind:
1. The device should have unobstructed line of sight to most coverage areas. For example, if installing in an office
filled with workspaces divided by mid-height cubicle walls, installing on the ceiling or high on a wall would be ideal.
2. Power over Ethernet supports a maximum cable length of 300 ft (100 m).
9

3. f being used in a mesh deployment, the AP should have line of sight to at least two other Meraki devices. A Cisco
Partner can help ensure that your AP placement is ideal.
nstall the AP
For most mounting scenarios, the access point mount cradle provides a quick, simple, and flexible means of mounting
your device. The installation should be done in two steps. First, install the mount cradle to your selected location. Then,
attach the AP to the mount cradle.
Attach the Mount Cradle
The access point mount cradle can be used to install your access point in a wide range of scenarios: wall or solid ceiling,
below a drop ceiling, on various electrical junction boxes.
The mount cradle contains a variety of hole patterns that are customized for each installation scenario. The mounting
template (included inbox with mount cradle) should be used to drill holes for wall mounts and also to identify the correct
hole patterns in the mount cradle that should be used for each type of mount. The included mount cradle
template shows the hole patterns that should be used for each type of mount.
Wall or Solid Ceiling Mount Using Mount Cradle
Using included wall anchors and screws, attach the mount cradle to your mounting wall or ceiling. t is recommended
that the AP be mounted to a wall or solid ceiling using the mount cradle for physical security reasons.
Drop Ceiling Mount using Mount Cradle
To mount your AP on a drop ceiling T-rail, use the included drop ceiling mounting accessory kit. The accessory kit can
be used to mount to most 9/16”, 15/16” or 1 ½” T-rails. The kit contains:
Drop ceiling mounting clips with set screws
6-32x4 mm screws
10
Table of contents
Other Cisco Wireless Access Point manuals

Cisco
Cisco WAP121 User manual

Cisco
Cisco MERAKI MR72 User manual

Cisco
Cisco Aironet 3500 Series User manual

Cisco
Cisco Aironet 3502P User manual

Cisco
Cisco Catalyst 9124AX Series Manual

Cisco
Cisco MR18 User manual

Cisco
Cisco Aironet 1530 User manual

Cisco
Cisco MERAKI MR72 Manual

Cisco
Cisco Meraki MR33 User manual

Cisco
Cisco ASR 1001 Manual

Cisco
Cisco Catalyst 9166I Series User manual

Cisco
Cisco Meraki Go GR62 User manual

Cisco
Cisco Aironet 1400 Series Manual

Cisco
Cisco AIR-LAP1310G User manual

Cisco
Cisco Meraki MR56 User manual

Cisco
Cisco ISR User manual

Cisco
Cisco WAP371 Instruction Manual

Cisco
Cisco WAP300N User manual

Cisco
Cisco M10-RM Quick start guide

Cisco
Cisco Meraki MR42 User manual