Carlisle Fluid Technologies Binks E2-30 User manual

EN
E2-30 E2-40
Service Manual
E2-30/40 Electric Drive
Pump
• 107075 (Japan Model)
• 107074 (USA Model)
• 107071 (EU Model)
• 107095 (Japan Model)
• 107094 (USA Model)
• 107093 (EU Model)
IMPORTANT! DO NOT DESTRO
Y
It is the Customer's responsibility to have all operators and service personnel read and understand this
manual.
Contact your local Carlisle Fluid Technologies representative for additional copies of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THIS PRODUCT
77-3215 R5.5 1/40 www.carlisleft.com

EN
Solvent and Water based materials
This Declaration of conformity / incorporation is issued under the sole responsibility of the
manufacturer:
Machinery Directive 2006/42/EC
ATEX Directive 2014/34/EU
EMC Directive 2014/30/EU
by complying with the following statutory documents and harmonized standards:
EN ISO 12100:2010 Safety of Machinery - General Principles for Design
EN 12621:+A1:2010 Machinery for the supply and circulation of coating materials under pressure - Safety
requirements
EN 1127-1:2011 Explosive atmospheres - Explosion prevention - Basic concepts
EN 13463-1:2009 Non electrical equipment for use in potentially explosive atmospheres - Basic methods and
requirements
EN 13463-5:2011 Non electrical equipment for use in potentially explosive atmospheres - Protection by
constructional safety "c"
EN 13463-8:2003 Non-electrical equipment for potentially explosive atmospheres. Protection by liquid immersion
'k'
EN 60079-0:+A11:2013 Explosive atmospheres - Equipment. General requirements
EN 60079-1:2014 Explosive atmospheres - Equipment protection by flameproof enclosures "d"
EN 60079-7:2015 Explosive atmospheres. Equipment protection by increased safety "e"
EN 60034-1: 2010 Rotating electrical machines
Providing all conditions of safe use / installation stated within the product manuals have been complied with and
also installed in accordance with any applicable local codes of practice.
Product Description / Object of Declaration:
Electric Pump E2, E4, EV2
This Product is designed for use with:
EU Declaration of Conformity
Suitable for use in hazardous area: Zone 1
Protection Level:
29/6/18
Bournemouth,BH11 9LH,UK
II 2 G X IIB T4 (Pump)
II 2 G Exd/Exde IIB T4 IP55 (Motor) CE0722
II 2 GD ck T4 (Gearbox)
Notified body details and role: Element Materials Technology (0891)
Lodging of Technical file
This Declaration of conformity / incorporation
is issued under the sole responsibility of the
manufacturer:
Carlisle Fluid Technologies UK Ltd,
Ringwood Road,
Bournemouth, BH11 9LH. UK
Si
g
ned for and on behalf of Carlisle Fluid
Technologies UK Ltd:
D Smith
Director of Sales (EMEA)
77-3215 R5.5 2/40 www.carlisleft.com

EN
WEAR SAFETY GLASSES. Failure to wear safety glasses with side
shields could result in serious eye injury or blindness. PROJECTILE HAZARD. You may be
injured by venting liquids or gases that
are released under pressure, or flying
debris.
DE-ENERGIZE, DE-PRESSURISE, DISCONNECT AND LOCK OUT ALL
POWER SOURCES DURING MAINTENANCE. Failure to de-energize,
disconnect and lock out all power supplies before performing
equipment maintenance could cause serious injury or death. KNOW WHERE AND HOW TO SHUT
OFF THE EQUIPMENT IN CASE OF AN
EMERGENCY.
NOISE LEVELS. The A-weighted sound level of pumping and spray
equipment may exceed 85 dB(A) depending on equipment settings.
Actual noise levels are available on request. It is recommended that
ear protection is worn at all times while equipment is in use.
PRESSURE RELIEF PROCEDURE.
Always follow the pressure relief
procedure in the equipment instruction
manual.
PROP 65 WARNING. WARNING: This product contains chemicals
known to the state of California to cause cancer and birth defects or
other reproductive harm.
PINCH POINT HAZARD. Moving parts
can crush and cut. Pinch points are
any areas where ther are moving
parts.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE
OPERATOR OF THE EQUIPMENT.
INSPECT THE EQUIPMENT DAILY. Inspect the equipment for worn or
broken parts on a daily basis. Do not operate the equipment if you
are uncertain about its condition.
OPERATOR TRAINING. All personnel
must be trained before operating
finishing equipment.
EQUIPMENT MISUSE HAZARD. Equipment misuse can cause the
equipment to rupture, malfunction or start unexpectedly and result in
serious injury. PACEMAKER WARNING. You are in the
presence of magnetic fields which may
interfere with the operation of certain
pacemakers.
WARNING
Read the following warnings before using this equipment.
READ THE MANUAL. Before operating finishing equipment, read and
understand all safety, operation and maintenance information
provided in the operation manual.
AUTOMATIC EQUIPMENT. Automatic
equipment may start suddenly without
warning.
In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as
follows:
WARNING CAUTION NOTE
Hazards or unsafe practices which could result in
severe personal injury, death or substantial property
damage.
Hazards or unsafe practices which could result in
minor personal injury, product or property
damage
Important installation, operation or maintenance
information.
HIGH PRESSURE CONSIDERATION. High pressure can cause serious
injury. Relieve all pressure before servicing. Spray from the gun,
hose leaks or ruptured components can inject fluid into your body
and cause extremely serious injury. KEEP EQUIPMENT GUARDS IN PLACE.
Do not operate the equipment if the
safety devices have been removed.
STATIC CHARGE. Fluid may develop a static charge that must be
dissipated through proper grounding of the equipment, objects to be
sprayed and alll other electrically conductive objects in the dispensing
area. Improper
g
roundin
g
or sparks can cause a hazardous condition
and result in fire, explosion or electric shock and other serious injury.
NEVER MODIFY THE EQUIPMENT. Do
not modify the equipment unless the
manufacturer provides written
approval.
77-3215 R5.5 3/40 www.carlisleft.com

'A'
'B'
SHC 630 Synthetic Oil
Max. Inlet Pressure 2 bar [29 psi]
Reduce Maximum working pressure by 2 bar [29 psi] when using in Open Loop Flow Mode
NOTE
* Pressure when used in 'Smart Mode' (Closed Loop Pressure Mode)
e.g. E2-15 Maximum Set Pressure of 18 bar to operate Pump on a 24/7 basis
40 l/m [10.6 US gal/m]
Fluid inlet connection:
Fluid outlet connection:
10 l/m [2.64 US gal/m]
30 l/m [8.0 US gal/m]
1.00 l/m [0.26 US gal/m]
7.5 l/m [2.0 US gal/m]
E2-40 Nominal flow volume / cycle:
E2-30 Fluid Output @ 20 HZ [10 cycles/min]
E2-40 Fluid Output @ 20 HZ [10 cycles/min]
E2-30 Fluid Output @ 80 HZ [40 cycles/min]
E2-40 Fluid Output @ 80 HZ [40 cycles/min]
1 ½'' Sanitary
Nominal pump stroke: 50mm [1.97 ins]
20.7 bar [300psi]
EN
16 bar [232psi]
SPECIFICATION
E2-30* Maximum fluid pressure:
E2-40* Maximum fluid pressure:
E2-30 Nominal flow volume / cycle: 0.75 l/m [0.20 US gal/m]
AC Induction Electric Motor - USA Model
460V 3PH 1 Hp @ 60HZ
Class 1, Group D.
Total Weight of Pump (inc electric motor) 250 kg [550 lbs]
0.75 kW 4Pole 1400 RPM EEx d 11B T3
Gearbox Ratio: 56:1
Gearbox Oil (EU Model) Synthetic 220 (typically Agip Blasia S)
Gearbox Oil (USA Model)
A
C Induction Electric Motor- EU Model 400V 3PH 1.5 kW @ 50HZ
Rated 20 to 80 Hz (c/w thermisters)0.75 kW 4Pole 1400 RPM - Japan Model
Rated 20 to 80 Hz (c/w thermisters)
77-3215 R5.5 4/40 www.carlisleft.com

EN
the Pump Frame must be wired to a suitable earth
g
round to ensure that there is no possibility of static
build up.
DIMENSIONS AND MOUNTING DETAILS
M6 HEX.
Head screw for pump earth
g
roundin
g
;
B
A
77-3215 R5.5 5/40 www.carlisleft.com

EN
The maximum pressure setting the Pressure Switch should be set to is 20 bar [305 psi] and 17 bar [246 psi]
respectively.
A
Pressure switch (and/or Pressure relief valve) must be connected to the outlet manifold port and set to stop the
pump (or relieve the fluid pressure) in the event of the system overpressure
This is necessary to protect the Pump mechanics from overload.
e.g. blocked paint filter, otherwise Pump warranty may be invalidated.
An adapter to mount a pressure switch and pressure sensor is available, see accessories.
It is recommended that the switch setting is set to 1 bar [14.5 psi] above the maximum required pressure.
The Pressure Switch is classified as simple apparatus and as such should be electrically connected as part of an
intrinsically safe electrical circuit.
The Pressure Switch should be wired as a Normally Closed contact (fail safe) and be hard wired to stop the motor
on operation, to minimise response time.
INSTALLATION
The Pump Units are designed for location in Zone 1 Hazardous areas, ATEX Category 2.
Electrical connections must be in accordance with Local Regulations for installation in Hazardous Areas.
It is recommended that a Local Control Box is positioned in close proximity to the pump, as a convenient local
Start / Stop facility and Junction box.
The main Pump Control Panel must be positioned within an Electrically Safe Area.
77-3215 R5.5 6/40 www.carlisleft.com

EN
1440 RPM
Rated Motor Current 3.8 A
Rated Motor Power Factor 0.81
Rated Motor Efficiency
INSTALLATION
Electric Motor
Rated Motor Frequency 50 Hz
Rated Motor Voltage 400 V
Rated Motor Speed
1.5 kW
Maximum Hz Output 80 Hz
Mininmum Hz Output 20 Hz
Acceleration Ramp
78 %
The motor is fitted with PTC temperature sensors (Thermistors).
Once operating temperature is reached, this device quickly changes the resistance;
If improperly used, badly connected, or altered no matter how minor, their reliability could be in doubt.
it must be connected to a suitable releasing device mounted within the control panel and wired to stop the motor
if an over temperature occurs.
Standards relating to the connection and use of electrical apparatus in hazardous areas must be taken into
consideration.
Only trained personnel familiar with these standards should handle this type of apparatus.
Required Inverter Settings
5 Seconds
0.1 Seconds
The motor must be wired to provide a clockwise direction of the cam.
Electric Motors for hazardous areas are specially designed to comply with official regulations concerning the risk
of explosion.
Inverter
Value
Deceleration Ramp
Rated Motor Power
77-3215 R5.5 7/40 www.carlisleft.com

EN
(The gearbox is filled with the correct amount of oil at the factory)
Ensure the gearbox is filled with oil.
Ø50 I.D. [-1 to 10 bar working pressure]
Outlet - Ø38 - 50 I.D. [20 bar working pressure]
Ensure adequate air space around the Pump for maintenance and electric motor cooling requirements.
Check that the oil plug on top of Gearbox has been replaced with the correct venting plug.
INSTALLATION
Attach suitable flexible hoses to the inlet and outlet connections.
e.g.,
Suction -
The vent plug is supplied in a bag attached to the gearbox.
77-3215 R5.5 8/40 www.carlisleft.com

EN
Set the pump cycle rate to achieve the required paint volume and then adjust the system back pressure regulator
to achieve the desired system fluid pressure.
Smart Mode:
The return line ‘back pressure’ regulator responds to the changes in system fluid flow demand, (due to variable
paint usa
g
e) by dynamically ad
j
ustin
g
the paint flow rate returnin
g
to the system paint tank, thus maintainin
g
the
set pressure.
Ensure all electrical and mechanical connections are correctly made.
All required interlocks are tested and operational.
Suitable material for pumping is available at the suction hose.
The outlet connection is not blocked or isolated by any valves.
Check the gearbox oil level, please note the the gearbox is supplied with life lubricant and does not need
any maintenance.
Set the pump speed to the minimum frequency 20 Hz and start the pump to remove any air from the circuit.
Inspect for any system leaks.
SYSTEM OPERATION
Before starting:-
77-3215 R5.5 9/40 www.carlisleft.com

EN
E2-40 MANIFOLD & PRV ASSEMBLY
E2-30 MANIFOLD & PRV ASSEMBLY 1194901
1194902
10
2COVER C/W CAP FIXINGS1945599
M12 SPRING WASHER (ST ST)
2
194249 2
7 165960 8
6
4 163126 4
E2-30/40 MECHANICAL ASSY
H063 ATEX GEARBOX
165044 8
8
192666 1.5KW ATEX MOTOR
3
M12 x 40 CAP HEAD SCREW
E2-30 FLUID SECTION
E2-40 FLUID SECTION
1
EU MODEL
(Not Shown)
USA MODEL
1192667 1.5KW ELECTRIC MOTOR
192669
H063 GEARBOX
H063 GEARBOX
M12 HEXAGON NUT
M12 WASHER
1
EU MODEL
PARTS LIST - Pump Assembly
192756 1
JAPAN MODEL
(Not Shown)
192670 1
USA MODEL
(Not Shown)
2
5 164470 4
192755
ITEM PART NUMBER DESCRIPTION QTY REMARKS
1 193709 1
77-3215 R5.5 10/40 www.carlisleft.com
This manual suits for next models
7
Table of contents
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual