Caple FGC620 User manual

Instruction manual for chimney hood
Instruction manual for chimney hoodInstruction manual for chimney hood
Instruction manual for chimney hood
Model code: FGC620 FGC720 FGC920
Contact Caple on 0844 800 8 0 or for spare parts www.caple.co.uk

Contents
Introduction 2
Safety precautions 2
Installation 4
Installing the charcoal filter 9
Operation 10
Care and maintenance 11
Troubleshooting 12
Guarantee 1
Environmental protection 14

2
Introduction
Thank you for choosing this Caple extractor hood.
To ensure that you get the best results from your new extractor, we
strongly suggest that you read this instruction manual thoroughly before
use.
. .
. If treated with care, your Caple extractor should give you years of
trouble-free use.
To register ownership, please ensure you complete and return the
guarantee card supplied with the appliance.
This instruction manual is designed to provide you with all required
information related to the installation, use and maintenance of the
appliance.
These cooker hoods are designed to extract unpleasant odours from the
kitchen; they are not intended to extract steam.
In order to operate the unit correctly and safety, please read this
instruction manual carefully before installation and use.
The cooker hood uses high quality materials, and is made with a
streamlined design. Equipped with an electric motor and centrifugal fan,
it provides strong extraction with low noise. It also features non-stick
grease filters and an easy installation.
Safety precautions
-
Never let the children operate this appliance.
-
The cooker hood is for home use only, not suitable for barbecuing,
restaurants or other commercial purposes.
-
The cooker hood and its filter should be cleaned regularly in order to keep
in good working condition.
-
Clean the cooker hood according to the instruction manual to reduce the
risk of fire.
-
When using a gas hob, do not leave naked flames under the extractor.
-
Before connecting this appliance check that the power supply cord is not

3
damaged. A damaged supply cord must be replaced by qualified service
personnel only. Please contact the Caple service department.
-
If the room where the hood is to be used contains a fuel burning
appliance such as a central heating boiler then its flue must be of the
sealed or balanced flue type. If other types of flue or appliances are fitted
ensure that there is an adequate supply of air to the room.
-
The air must not be discharged into a flue that is used for exhausting
fumes from appliances burning gas or other fuels.
-
Regulations concerning the discharge of air have to be conformed to.
-
This appliance if not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person slide for their safety.
-
Children should be supervised to ensure that they do not play with the
appliance.
-
Do not flambé under the cooker hood.
-
Never leave frying pans unattended during use as over-heated fats and
oils may catch fire.
-
To ensure the best performance, we recommend switching on the
extractor 15 minutes before cooking and leave it running 15 minutes after.
This will ensure that the air in the kitchen is being circulated before
cooking commences and the air is being cleaned after cooking has
finished.
-
The performance of your extractor will vary depending on a number of
factors. These include type of extraction, room volume, length of ducting,
ventilation available and the cleanliness of the filters.
Electrical shock hazard
-
Only plug this unit into a properly earthed outlet. If in doubt seek advice
from a suitably qualified engineer.
-
Failure to follow these instructions can result in death, fire, or electrical
shock.
-
This appliance must be connected to the mains by a competent person.
We recommend that the appliance is connected by a qualified electrician
who is a member of the N.I.C.E.I.C. who will comply with the I.E.E. and
local regulations. Electrical information can be found on the rating plate.

4
Installation
Prepare for the installation:
a. If you have an outlet to the outside, your cooker hood can be connected as
per the below picture by means of an extraction duct with an interior
diameter of 150mm)
b. Before installation, turn the unit off and unplug it from the outlet.
c. The cooker hood should be placed at a minimum distance of 65~76cm above
the hob. It is the manufacturer of the hob who determines the clearance
required and the clearance quoted by the hob manufacturer must be
followed. In the absence of any instructions supplied with a gas hob the
minimum distance between the hob and the hood must be at least 760mm.
65cm
- 76cm

5
Installation – ducted
Attent
AttentAttent
Attention! Obs
ion! Obsion! Obs
ion! Observe the warning
erve the warning erve the warning
erve the warning concerning the operation of the appliance
concerning the operation of the appliance concerning the operation of the appliance
concerning the operation of the appliance
when air is discharged from the room.
when air is discharged from the room.when air is discharged from the room.
when air is discharged from the room.
When the cooker hood and appliance supplied with energy other than electricity
are simultaneously in operation, the negative pressure in the room must be not
exceed 4 Pa (4×10
-5
Bar)
Drill x 8mm holes to accommodate the bracket. Screw and tighten the
bracket onto the wall with the screws and screw plugs provided.
Level up the cooker hood and hang onto the wall bracket hook.
Screw
/wall
plug
Wall bracket
Screw
(4mm x 0mm)
Holes on wall
Wall bracket
Cooker hood

6
Fix the one-way-valve to the air outlet of the cooker hood. Then, attach the
exhaust pipe onto the one-way-valve as shown below.
Chimney installation.
Chimney installation.Chimney installation.
Chimney installation.
Place the upper chimney into lower chimney, then pull the upper
chimney upwards. Adjust the section to reach the height required.
Exhaust pipe
Cooker hood

7
Slide the chimney to adjust the chimney height. When the height you
require is reached, attach the fixing hole to the fixing screws as shown
in below diagram.
Drill 2×8mm holes to accommodate the plate II. Screw and tighten the
plate II onto the wall with the 2 screws provided. Assemble the
chimney onto the unit and fix it with the 2 screws.
Upper
chimney
Lower chimney
Plate II
S
crew/
wall
plug
Screw (4mmx8mm)
Screw (4mmx 0mm)

8
Installation – recirculation mode
Install the hood as shown in the previous section. If you do not have an
outlet to the outside, the exhaust pipe is not required (as shown in the
section “Installation - ducted”). A charcoal filter will be used to clean the
air.

9
Installing the charcoal filter
An activated charcoal filter can be used to trap odours.
In order to install the charcoal filter, the grease filter should be detached
first. Press the release button and pull it downward as shown below.
Fit the activated charcoal filter onto the side of the motor and turn it in a
clockwise direction to lock into place. Repeat the same on the other side.
NOTE:
- Make sure the filter is securely locked. Otherwise, it may loosen and
be dangerous.
- When using a charcoal filter, the extraction power may be slightly
reduced.
Other manuals for FGC620
1
This manual suits for next models
2
Table of contents