Can-Am Hero-BK-PM User manual

1
CAN-AM Linux Access Control with AI Thermal detector
User Manual
Model: Hero-BK-PM

2
CONTENTS
1. PRODUCT OVERVIEW .............................................................................................................................3
1.1 PRODUCT INTRODUCTION............................................................................................................................. 3
1.2 PRODUCT FUNCTIONS .................................................................................................................................. 3
2. WIRING INSTRUCTIONS..........................................................................................................................3
2.1 WIRING INSTRUCTIONS ................................................................................................................................. 4
2.2 CONNECT THE DEVICE TO PC....................................................................................................................... 5
2.3 CONNECT THE LOCK OF DOOR (PUSH_OUT)............................................................................................... 6
2.4 WIRING INSTRUCTIONS(LOCK_NONC_12V )..................................................................................... 6
3. CLIENT OPERATIONS..............................................................................................................................7
3.1 DEVICE MANAGEMENT ................................................................................................................................. 8
3.1.1 Login..................................................................................................................................................... 9
3.1.2 Adding Device ................................................................................................................................... 11
3.1.3 Device Settings ................................................................................................................................. 12
3.2 STAFF MANAGEMENT.................................................................................................................................. 17
3.2.1 Adding Staff ....................................................................................................................................... 17
3.2.2 Batch-adding From file..................................................................................................................... 19
3.2.3 Edit Users .......................................................................................................................................... 19
3.2.4 Delete ................................................................................................................................................. 20
3.2.5 Staff Sync .......................................................................................................................................... 21
3.2.6 Clearing Device users...................................................................................................................... 23
3.2.7 Blacklist and White-list..................................................................................................................... 24
3.2.8 Device Access Control Parameters ............................................................................................... 25
3.2.9 Authority Group................................................................................................................................. 26
3.3 VOICE OF NOTIFICATION ............................................................................................................................. 29
4. DATA QUERY ...........................................................................................................................................29
4.1 UPDATING ATTENDANCE RECORDS............................................................................................................ 29
4.2 EXPORT ATTENDANCE RECORD ................................................................................................................. 30
4.3 CLEAR RECORD.......................................................................................................................................... 31
5. FAQ ........................................................................................................................................................... 31

3
1. Product Overview
1.1 Product Introduction
CAN-AM Access Control with AI thermal detector Hero-BK-PM adopts the new AI chip-set, large
thermal sensor array, and latest algorithm, providing the cutting-edge face recognition and body
temperature detection, with ability to detect wearing the mask. Hero-BK-PM can identify human
forehead automatically from 0.3meter ~1.2meter to get ±0.3℃high accuracy body temperature
within 0.05second.
1.2 Product Functions
Proximity wake-up activation: the device is automatically activated when a person
approaches.
7-inch touch screen: displays the software interface, operation guidance and face frame.
Performs real-time face detection (supports local video preview).
2 million pixel binocular wide angle camera.
Anti-fake function for pictures and videos.
Facial recognition distance of up to 1 meter, for a height range of 1.4m to 1.9m.
Use of deep learning algorithms to support a capacity of 50,000 faces. Fast recognition
with a higher recognition rate.
Storage of up to 50,000 events.
Multiple authentication methods.
Facial comparison time ≤ 0.5s/person. Recognition rate ≥99.9%.
Support for importing of card and facial data to devices through TCP/IP transmission or
USB interfaces.
Uploading of data through the internet.
Uploading of comparison results and interconnected snapshots to the platform for
storage.
Personnel information can be sent down from the platform or uploaded from local
devices.
Stand-alone operation in offline mode.
Local login for managing, searching and configuring device parameters.
2. Wiring instructions
Face recognition terminal can be docked through the tail line access control locking, in the
retention of existing access control system function of the colleague, the access control intelligent
operation upgrade. It is possible to simulate the opening of the door with the PUSHOUT signal and
directly drive the electromagnetic anode or cathode locks with the LOCKNONC signal.
For direct drive of Anodic or cathodic locks, a 12V/2A switched power supply is recommended.
Note the following while wiring.
If 1.0mm national standard wire is used, 12V switching power supply is used, and the wiring

4
distance from the site construction (switching power to equipment distance) does not exceed
20m.
If 1.5mm national standard cable is used, 12V switching power supply is used, and the wiring
distance from the site construction (switching power to equipment distance) does not exceed
30m.
If 2.0mm national standard wire is used, 12V switching power supply is used, and the wiring
distance (switching power to the equipment distance) is not more than 40m.
2.1 Wiring instructions
The wiring instructions are shown in the table below.
Wire Description Function
Wire
sequence
Name
Description
A DC IN POWER 1 12VDC in
12V power supply, 2A
2 GND
Ground
B Type-A USB USB Host
1 5V
Only used for factory testing.Do
Not connect it.
2 DN
3
DP
4
GND
C RJ45 Ethernet 1 Ethernet
Standard 100 megabit network
port, connect to PC for
configuration.
D OUT-4pin lock control
signal
1
PUSH_OUT
Switching Level Output
2 LOCK_NONC_12V
12V switching drive output
3 GND
Ground

5
4 12V out
12V power output
E 2 pin Reserved 1
N/A
, don’t connect anything!
2
Precautions:
1). Pin 4 (12V out), current limit output 1A, load beyond power, will cause panel machine hardware
damage.
2). Pin 2 (LOCK_NONC_12V), current limit output 800mA, beyond the power of the latch access,
will cause panel machine hardware damage.
3). Pin 2 (LOCK_NONC_12V) and pin 3 (GND), please do not short-circuit, otherwise it will cause
hardware damage to the panel machine.
4). Pin 1 (PUSHOUT) and pin 4 (12V out), please do not short-circuit, otherwise it will cause
hardware damage to the terminal.
2.2 Connect the device to PC
Connect the network cable via RJ45 to your PC directly or router.
The default IP address of device is 192.168.1.100, and it supports DHCP as default mode.
A. If there is a router, you can connect the device to router via RJ45 cable. Then you will get the
current IP address on the TFT screen, then search this device via your PC’s ARfacemanger (You
PC should be in the same router).
B. If there is a wireless router. You can only add the 192.168.1.*** IP segment in Advanced as the
following pictures. And connect the device to your PC directly, then search and set it via
ARFacemanager.

6
3. Turn off firewall of your PC
(
fWindows 10 OS
)
. After you configure it, you can turn the
firewall on again.This is only affect the search IP address of device. If not turn it off, you can add
the device by manually.
2.3 Connect the Lock of door (Push_out)
A. Conventional access control system, generally with a button to open the door function, it is
recommended that the terminal PUSHOUT terminal directly and connected to the open the door
button wiring, in line with the permission to open the door action through PUSHOUT directly
simulate the button grounding operation, does not affect the original door button function.
2.4 Wiring instructions(LOCK_NONC_12V )
The hardware wiring is as follows, the switching quantity signal can be directly output 12V, no
external power supply is required to power the lock.
Note: The original door controls cannot be unlocked when the power is removed.

7
Anode Lock
Software Configuration: In the ARFaceManager tool, go to 3.2.8 Device Access Control
Parameters and set the door magnet type to "Normally Closed".
Cathode Lock
Software Configuration: In the ARFaceManager tool, go to 3.2.8 Device Access Control
Parameters and set the door magnet type to "Normally Open".
3. Client operations
You can set up and operate your device through client ARFaceManager.exe. This chapter
introduces the functions and operating procedures of access control.
The main interface contains System menu, 4-channel preview interface, identified staff info
(temperature, mask, name) and UN-identified staff info (temperature, wear mask or not).

8
Video Preview: You can get the live streaming info;
Device Manage: Search, edit and set the device.
Staff Manage: Add/edit/delete the staff personal info, and authorize the door-Lock function.
Data Query: Export the attendance of registered staff.
3.1 Device Management

9
3.1.1 Login
For the first time login, you need set a password (Six characters at least) for admin account. After
login on, you can create sub-account, and set the role for the sub-account.
Add sub-account, input the user and password. Select the Authority(role) for this account.

10
Delete account. Select it first, then Click “Delete Account”.
Table of contents