CONTROL BOARD
1 2 3 4 5 6 7 8 9 10 11 12 04 05 06 07 08 V1 V2 V3 V4 V5
1 A
1A
ESC ENTER
RSE
>
<
PROGRAMMING FUNCTION
R700
AF
CONTROL BOARD FUSE ACCESSORIES FUSE
LINE FUSE 3.15A
1 0 1 1 12 4 5 7 T S
F C FA F + E -
2 6
V S
230
4
3
2
1
0
1 7
0
WARNING!
A B G N D
230V control board
for C-BXE gearmotors

Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
2
English
2.1 Intended use
2 Intended use and use limits
The ZCX10 electric board has been designed for the CBX E automation control of sectional-, sliding- and industrial swing gate
movement.
Any use other than the above, and installations with procedures different to those in the
following technical manual, are forbidden.
2.2 Use limits
1 Legend symbols
This symbol indicates sections to read carefully.
This symbol indicates sections regarding safety.
3.2 Dimensions and interaxes of fixing holes
3 Product description
215 mmĐ
295 mmĐ
240 mmĐ 145 mmĐ
120 mmĐ
320 mmĐ
3.1 Board description
The ZCX10 electric board has been designed for controlling the CBX automation, for moving sectional-, sliding- and swing
gates, 230V-powered with power up to 600W, and 50−60 Hz frequency.
Designed and built entirely by CAME S.p.A., it meets the UNI EN 12453 standards.
ABS casing with IP54 protection level, equipped with intake for air circulation and complete with transformer.
The circuit should be powered at 230V in the L-N terminals and protected by a 5A fuse, while
the low voltage command devices are protected with a 1A fuse.
The total power of the (24V) acessories must not exceed 20W.
The board includes the manoeuvre pick-up function, which is activated at the start of the gate’s opening and closing phases
- Class of isolation II;
- Earth’s connection for the electric safety of the parts non functional day-pupils to the container with electronic card of
command are to perform on the suitable points.
Attention: before intervening inside the equipment to remove the tension of line
This manual is intended only for the technical personnel qualified for the installation.

3
Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
English
3.3 Board description
ZCX10
CONTROL BOARD
1 2 3 4 5 6 7 8 9 10 11 12 04 05 06 07 08 V1 V2 V3 V4 V5
1 A 1A
ESC ENTER
RSE
>
<
PROGRAMMING FUNCTION
R700
AF
CONTROL BOARD FUSE ACCESSORIES FUSE
LINE FUSE 3.15A
1 0 1 1 12 4 5 7 T S
F C FA F + E -
2 6
V S
230
4
3
2
1
0
1 7
0
WARNING!
A B G N D
2
1
3
4
5
7
9
8
6
12
11
10
1 - Transformer (not included)
2 - Condenser bracket
3 - Board Fuses 1 A,Acessories fuse 1A.
4 - Display
5 - Programming buttons
6 - Memory roll connector
7 - Connector for R700 board
8 - HF card connector
9 - Terminal board
10- Power supply
11- Line Fuse 3.15 A
12 - RSE card connector
13 - Led -- of signaling
13
13

Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
4
English
4.2 Tools and materials
Ensure you have all the tools and materials necessary for carrying out the installation according to current safety standards.
See the following examples.
4 .1 Preliminary checks
4 Installation
Installation must be carried out by qualified and expert personnel, fully respecting the current standards.
Before attempting installation, you must:
• Ensure that the control board fixing point is in an area protected from bumps and that the anchoring surfaces
are secure and solid.
• Make provision for a suitable omnipolar disconnection device, with power supply cut-off, leaving more than 3 mm between
the contacts
Assemble the spring-type hinges, insert the hinges into the housing (on the) left or
right as preferred) and secure with
the screws and washers supplied they flow for rotating
15 mm~
!!
Snap the cover over the hinges, then close and secure it
using the screws supplied
3.4 Assembling hinge housing
12
3

5
Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
English
4.3 Electrical connections
230V AC Output 25W max. (in
movement) for flashing lamp
RS232 cable
PC 40 o PC30
Personal
Computer
Serial communication for PC connection, use bipolar shielded cable mod.
RS235
Connection for encoder (for the connection between the automation and the electric
picture to use cable screened type 2402C 22AWG)
(1.2) STOP pushbutton Normally Closed
(2.3P) Partial opening pushbutton Normally open
(2.3) Total opening pushbutton Normally open
230V power supply
Single phase 230V A.C motor max capacity: 600 W
10 11 1 2 3 4 5 7 CX CY TS
3P
10 11 1 2 3 4 5 7 CX CY TS
3P
+ E
-
A B GND
L N
U V W E
U V W E
+
-
E
M
E
-
+ E
-
-
10 11 1 2 3 4 5 7 CX CY TS
3P
1
1
Condenser 20µF 420V.

Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
6
English
4.3 Electrical connections
(2.4) Close pushbutton Normally Open (N.O.)
(2.7) Stepper contact, Normally Open sequence
(10.5) Pilot light Opens 24V 3W
10 11 12 3p 34 5 7CX CY TS
Rx Tx
Tx 2
10 2 TX C NC
10 11 12 3p 34 5 7CX CY TS
N.O.
C.
N.C.
++
--
Rx Tx
(2,CX) DOC and DIR photoelectric cell connection
DIR DIR
DOC
10 11 12 3p 34 5 7CX CY TS
N.O.
C.
N.C.
++
--
Rx Tx
10 11 12 3p 34 5 7CX CY TS
Rx Tx
Tx 2
10 2 TX C NC
(2,CY) DOC and DIR photoelectric cell connection
DIR DIR
DOC
10 11 1 2 3 4 5 7 CX CY TS
3P
10 11 1 2 3 4 5 7 CX CY TS
3P
10 11 1 2 3 4 5 7 CX CY TS
3P
10 11 1 2 3 4 5 7 CX CY TS
3P
(10-11) output 24V A.C. feeding accessories (max 20 W)

7
Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
English
4.3 Electrical connections
10 11 12 3p 34 5 7CX CY TS
Rx Tx
Tx 2
10 2 TX C NC
10 11 12 3p 34 5 7CX CY TS
N.O.
C.
N.C.
++
--
Rx Tx
DIR
DOC
DOC and DIR photoelectric cell TEST
CAME
R700
AF
R700
AF
(S1-GND) connection sensory TSP00 (trasponder) LT001 (creeping)
N.B. to make to recognize the sensors to the card, needs to connect the special card of coding (R700)..
Antenna connection
Red
Black
ACCESS CONTROL
R700
AF
CANCELLIAUTOMATICI R700
CANCELLIAUTOMATICI R700
TSP00
LT001
Red
Black

Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
8
English
ESC ENTER
><
PROGRAMMING FUNCTION
Operation Time
12 sec
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LANGUAGE
< >
5 Programming
ESC ENTER
><
PROGRAMMING FUNCTION
LANGUAGE
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
5.1 Display commands description
The ENTER button is used for :
- entering the menu
- confirming and saving the default value
The ESC button is used for:
- quitting the menu
- cancelling changes
The < > buttons are for:
- moving from one menu to another
- inreasing or decreasing a value
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
< > are for:
- confirming the currently selected item
5.2 Moving around the menu
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LANGUAGE
< >
ESC ENTER
><
PROGRAMMING FUNCTION
TIMING
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
Auto Clo.Time
20 sec
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
Auto Clo. Time
45 sec
< >
ESC ENTER
><
PROGRAMMING FUNCTION
Auto Clo.Time
20 sec
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
To enter the menu,
hold down ENTER
for at least one second.
To select the
menu item, move
the arrows
until you reach
the one required.
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
Then press ENTER
also for the
menus below, move
the arrows
until you reach
the one required..
Then press ENTER
If the <> arrows are
pointing on the time,
this means
it can be changed.
To increase or decrease the
value, click on the arrows
until you reach the one
required.
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
Then press ENTER to
confirm
To quit the menu,
wait 30 seconds or
press ESC, until
the initial screen appears
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
N.B. when the menu is active, you cannot carry out any manoeuvres.
...........
WWW.CAME.IT
CBX

9
Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
English
FUNCTIONS
LANGUAGE Select Languag
Italian
Englisch
French
< 10 sec >
< 10 sec >
Auto Clo Time
< 10 sec >
PreFlasch Time
< 10 sec >
Pedestrain ACT
5.3 Menu structure
TIMING
<ON >
<OFF>
Auto Closing
<ON >
<OFF>
Pre Flashing
<ON >
<OFF>
Dead Man
OFF
Enable on CX
Safety Test
<ON >
<OFF>
Obstacle Pres.
Open-Stp-Close
Open Close
Input 2-7
2-7Function
Opening Only
User Function
C1
Disabled
Input CY
<ON>
<OFF>
Stop Button
Cycle
Movment
Flashin Light
<OFF>
<ON>
Dead mean Clos
F.C2
Disabled
F.C6
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
n.4 Exist!
Writing ...
Users Backup
Pediastran Op.
User Function
Edut User
Add New User
n.5 empty
n.4 Exist!
n.5 empty
Delete User
Reading ...
Users Restore
Are you sure
<Yes>
Dlete All
<NO>
RADIO/
USER
<ON >
<OFF>
Close Thrust
<ON >
<OFF>
Closing Brache
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
Procedure....
Run Calibrat.
< 15% >
Slowing Run
+oooo-
Obstacle Sens.
•
< 40% >
Pedestrian Run
SETUP
Press ENTER for 1 second
Input CX
C6
Operation Time
ENTER
>
ENTER
ENTER
ENTER
>
>
>
>
>
>
ENTER
ENTER
ENTER
ENTER
ENTER
>
>
>
>
ENTER
< >
< >
>
>
>
>
< >
>
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
< >
< >
< >
< >
< >
>
>
>
ENTER
ENTER
ENTER
< >
< >
< >
ENTER
ENTER
ENTER
ENTER
ENTER
< >
< >
< >
< >
< >
< >
< >
>
>
>
>
>
>
>
>
>
< >
< >
< >
< >
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
< >
>
>
>
>
>
>
< >
< >
< >
< >
ENTER
ENTER
ENTER
ENTER
ENTER
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
ESC ENTER
><
PROGRAMMING FUNCTION
LINGUA
< >
Procedure....
Firmware Vers
N.of manouvers
Welcome Note
(Visual only)
(Visual only)
INFO
>
>
>
ENTER
ENTER
>
>
< >
Opening Slowly
+oooo-
•
Disabled
< >
ENTER
Networ Aaddr. 1 <-> 16
< >
ENTER
>

Tutti i dati e le informazioni quì contenute sono da ritenersi susciettibili di modifica in qualsiasi momento e a nostro giudizio
10
English
Language
Language selection: select the language required.
Select Languag.
Italian
LANGUAGE
Englisch French
GermanSpanischDutch
Times
Work time: Time of motor operation in the single opening/closing phase
TIMING Operation Time
< 10 sec >
A.C.T.: automatic closing time after an opening command..
TIMING
< 10 sec >
Auto Clo Time
x 1
Pre-flashing time: pre-flashing duration.
TIMING
< 10 sec >
x 2 PreFlasch Time
Pedestrian A.C.T.: automatic closing time after an pedestrian opening command
TIMING
< 10 sec >
x 3 Pedestrain ACT
Functions
Automatic Closure: Enables/disables the automatic closing function
<ON >
<OFF>
Auto Closing
FUNCTIONS
Command 2-7: Sets the sequential- or stepper contact.
x 1
Open-Stop-Close
Open Close
Input 2-7
FUNCTIONS
User function: Sets to the user or the open-only command, or the function associated to the 2-7 command.
x 2
FUNCTIONS User Function
2-7Function
Opening only
Pre-flashing: Enables/disables the pre-flashing function.
x 3
FUNCTIONS Pre Flashing
<ON >
<OFF>
5.4 Menu items
ENTER
ENTER
>>
>
>>
>
ENTER
ENTER
ENTER
ENTER
< >
< >
ENTER
ENTER
>
ENTER
< >
< >
< >
ENTER
ENTER
>
>
ENTER >
ENTER >
ENTER >
ENTER
ENTER
ENTER
< >
< >
< >
ENTER
Other manuals for ZCX10
2
Table of contents
Other CAME Gate Opener manuals
Popular Gate Opener manuals by other brands

SOMFY
SOMFY Dexxo RTS Pro INSTALLATION INSTRUCTIONS-ILLUSTRATIONS

Cardin
Cardin BL Series manual

Westfalia
Westfalia 85 27 06 instruction manual

Extel
Extel VERA quick guide

Comunello Automation
Comunello Automation ABACUS 220 Installation and user manual

Mighty Mule
Mighty Mule 200 E-Z GATE OPENER UL325 SERIES installation manual