Calimet CM9-2 Installation instructions

CALIMET
GATE ACCESS CONTROL SYSTEMS
INSTALLATION AND OWNER MANUAL
V.3.1 | 2023.06.01WWW.CALIMETCO.COM
9949 HAYWARD WAY, SOUTH EL MONTE, CA 91733
TEL: 626.452.9009
SWING LINEAR ARMS OPERATOR
CM9-2

TABLE OF CONTENTS
OVERVIEW GATE OPERATOR OVERVIEW
SAFETY
PROPERTY TYPE AND ENTRAPMENT PROTECTION
...................................................................................... 01
02 - 03
04
....................................................................................................................
................................................
INSTALLATION PREINSTALLATION
CONTROL BOX INSTALLATION
LINEAR ARM INSTALLATION
ARM POSITIONING GUIDANCE
CIRCUIT BOARD LAYOUT
DIP SWITCH FEATURES
CONTROL BOX WIRING
POWER CONNECTION
GATE OPEN DIRECTION SETTINGS
DUAL GATE WIRING AND SETUP
PHOTOCELL SENSOR INSTALLATION
PHOTOCELL SENSOR LED INDICATORS
SECONDARY PHOTOCELL SENSOR (OPTIONAL)
PHYSICAL LIMITS ADJUSTMENT
FORCE ADJUSTMENT
WARNING SIGNS INSTALLATION
EMERGENCY RELEASE LOCK
AFTER INSTALLATION
........................................................................................................ 05
06
07 - 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
....................................................................................
..................................................................................
.....................................................................................
..............................................................................................
................................................................................................
.................................................................................................
..................................................................................................
.............................................................................
...................................................................................
..........................................................................
.....................................................................
......................................................
..................................................................................
...................................................................................................
....................................................................................................
..................................................................................
......................................................................................
ACCESSORIES
WIRING
REMOTE CONTROLS
VEHICLE LOOP DETECTORS
ACCESSORY WIRING
..................................................................................................... 26
27 - 29
30 - 32
.................................................................................
..............................................................................................
IMPORTANT
INFORMATION
CIRCUIT BOARD LIGHT STATUS CHART
TROUBLESHOOTING
MAINTENANCE
MANUFACTURER’S LIMITED WARRANTY
IMPORTANT INFORMATION AND NOTES
...................................................................... 33
34
35
36
37
.....................................................................................................
...............................................................................................................
....................................................................
.....................................................................

POWER IMPUT 110 - 120V AC, CM9-2-DCFP/DCFP-S: 7 AMPS
SYSTEM OPERATION VOLTAGE CM9-2-DCFP: 24V DC
MAXIMUM OUTPUT CURRENT 7 AMPS, FUSE 24V DC 7 AMPS
DIMENSIONS CONTROL BOX: (L x W x H)
LINAER ARM: (L x W x H)
GATE TYPE SWING LINEAR ARM
RESIDENTIAL / COMMERCIAL
1600 LBS
18 FEET
-4°F TO 140°FOPERATING TEMPERATURE
MAXIMUM GATE LENGTH
APPROXIMATELY 20 SEC FOR 90° OPENING (ADJUSTABLE)
CONTINUOUSMAXIMUM DUTY CYCLE
MAXIMUM GATE TRAVEL SPEED
INHERENT REVERSE SENSOR SYSTEM (TYPE A)
PHOTOELECTRIC SENSOR (TYPE B1)EXTERNAL ENTRAPMENT PROTECTION
INHERENT ENTRAPMENT PROTECTION
CM9-2-DCNB: NO, CM9-2-DCFP/DCFP-S: YES
KEYEMERGENCY RELEASE
SOLAR READY
I, II, III, IV
RESIDENTIAL: 5 YEARS, COMMERCIAL: 3 YEARS
GATE OPERATOR OVERVIEW
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 01
WARRANTY
CM9-2-DCNB PACKAGE
CONTROL BOX (1), SWING LINEAR ARM (1), CM9-864 CONT-
ROL (2), PHOTOSENSOR AND REFLECTOR (1), PHOTOSEN-
SOR MOUNT (2), WARNING SIGN (2), NUTS AND BOLTS (1),
MOUNTING HARDWARE, USER MANUAL, WARRANTY CARD.
CM9-2-DCFP PACKAGE
CM9-2-DCNB PACKAGE, BATTERY (1), BATTERY CIRCUIT
BOARD (1)
CM9-2-DCFP-S PACKAGE
CM9-2-DCFP PACKAGE, EXTENDED SOLAR BATTERY (1),
SOLAR PANEL *2)
WHAT’S IN THE BOX
PROPERTY CLASS
APPLICATION
MAXIMUM GATE WEIGHT

SAFETY (MUST READ)
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 02
Carefully read follow, and accept all safety precautions and warnings before attempting to install and use
gate swing linear arm operator, incorrect installation can lead to severe injury or death.
- The gate operator must be installed by a certified (licensed) gate technician; otherwise serious personal
injury or property damage may occur.
- Installing a gate operator may require installation of standard 110v-120v AC electrical wiring. This work
should only be performed by an experienced electrician. Miswiring could cause personal injury or death.
- Never let children operate the gate or play around the gate. Keep the remote control away from children.
- Always keep people and objects away from the gate. Cars, people, and objects should never enter when
the gate is closing.
- Verify that this operator is proper for the type, weight, and size of the gate.
- Make sure the gate has been properly installed and swings freely in both directions with no resistance.
Repair or replace all worn or damaged gate hardware prior to installation.
- Test gate operator monthly. The gate must reverse when in comes in contact with a solid object, or stop
when an object activates the non-contact sensors. after adjusting the force or travel limit, re-test the gate
operator. Failure to maintain the gate operator properly can increase the risk of injury or death.
- Use the emergency release only when the gate is not moving.
- Keep the gate and gate operator properly maintained. Read the maintenance section of this manual and
follow the maintenance schedule. Have a certified service technician make repair or install gate operator
hardware(s).
- Gate operator can use a huge amount of force to open and close the gate. Therefore, safety features
must be taken into consideration when installing and using a gate operator. Specific safety feature include:
photoelectric sensors, edge sensors (contact), moving gate warning signs, guards for exposed rollers,
screen mesh, vertical posts, and more.
- The gate must be installed in a location so that enough clearance is supplied between the gate and
adjacent structures when opening and closing to reduce the risk of entrapment.
- Entrapment is defined as when a person, vehicle, or object is caught or held in a position that increases
the risk of injury.
- Access controls intended for users must be located at least 6 feet (1.8m) away from any moving part of
the gate and where the user is prevented from reaching over, under, around, or through the gate to
operate the controls.

- A minimum of two (2) warning signs shall be installed, one on each side of the gate that is easily visible.
- Gate auto closed timer function is not recommended unless loop detectors are installed.
- The gate must have sufficient room when opening and closing. Swinging gates should open inwards and
not into public access areas. The gate must be properly installed and move freely in both directions.
- Install the gate operator only when: 1) The operator is appropirate for the construction of the gate and the
usage class of the gate, 2) All exposed pinch points are eliminated or guarded.
- For gate operators utilizing Type D protection: 1) The gate operator controls must be placed so that the
user has full view of the gate area when the gate is moving, 2) The placard shall be placed adjacent to the
controls, 3) An automatic closing device (such as timer, loop sensor, or similar devices) shall not be
employed, and 4) No other activation device shall be connected.
- The gate operator is intended for installation only on vehicular gates. Pedestrians must access a
separate entrance. The pedestrian entrance shall be designed for pedestrian usage. The gate must be
installed in a location so that pedestrians will not come in contact with the vehicular gate during the entire
path of travel of the vehicular gate.
- For gate operators utilizing a non-contact sensor, see instructions on the placement of non-contact
sensors for each Type of application, 2) Care shall be exercised to reduce the risk of nuisance tripping
such as when a vehicle, trips the sensor while the gate is still moving, and 3) One or more non-contact
sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter
reachable by a moving gate or barrier.
- For a gate operator utilizing a contact sensor: 1) one or more contact sensors shall be located at the
leading edge, trailing edge, and post mounted both inside and outside of a vehicular gate. 2) One or more
contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3) One or more contact
sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4) A hardwired contact sensor
shall be located and its wiring arranged so that the communication between the sensor and the gate
operator is not subjected to mechanical damage. 5) A wireless contact sensor such as one that transmits
radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located
where the transmission of the signals are not obstructed of impeded by building structures, natural land-
scaping or similar obstructions. A wireless contact sensor shall function under the intended end-use cond.
- Controls intended to be used to reset an operator after 2 sequential activations of the entrapment
protection device(s) must be located in the line-of-sight of the gate. Outdoor or easily accessible controls
shall have a security feature to prevent unauthorized use.
SAFETY (MUST READ)
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 03

PROPERTY TYPES & ENTRAPMENT PROTECTION
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 04
Required Entrapment Protection
A
B1
B2
C
D
E
Class I - Residential
Intended for use in a home of one (1) to four (4) single family dwelings, garage or parking area associated
therewith
Swing Gate Requirements: Primary Device: A, C
Secondary Device (one required): A, B1, B2, C, D
Class II - Commercial
Intended for use in a commercial location or building such as a multi-family housing unit (five or more
single family units, hotel, garages, retail store or other building servicing the general public.
Swing Gate Requirements: Primary Device: A, C
Secondary Device (one required): A, B1, B2, C, D
Class III - Industrial
Intended for use in an industrial location or building such as a factory, loading dock area, or other locations
not intended to service the general public.
Swing Gate Requirements: Primary Device: A, B1, B2, C
Secondary Device (one required): A, B1, B2, D, E
Class IV - Restricted Access
Intended for use in a guarded industrial location or building such as a military base, hazardous chem sites,
or other restricted access locations, in which unauthorized access is prevented via supervision by staffs.
Swing Gate Requirements: Primary Device: A, B1, B2, C, D
Secondary Device (one required): A, B1, B2, C, D, E
NOTE: A minimum of 2 independent entrapment protection devices are required for each direction of travel.
The same type of device shall not be utilized for both the primary & secondary entrapment protection means
Use of a single device to cover both the opening & closing directions is in accordance with the requriement;
however, a single device is not required to cover both directions.
Inherent (built-in) Entrapment Protection System
Non-contact sensor such as a photosensor or equivalent
Contact sensor such as edge sensor or equivalent
Inherent adjustable clutch or pressure relief device
Actuation device requiring contrinuous pressure to maintain gate motion
Inherent Audio Alarm
-
-
-
-
-
-

PREINSTALLATION
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 05
Gate Structure
Confirm that the gate operator being installed is appropriate for the gate type, weight and size. The gate
should be mounted and moving freely. There should be a little resistance in the movement of the gate. the
gate & post must be suitable for being automated. Check that the structure is sufficiently strong & stable,
and that its dimensions and weights conform to those listed in the specifications table of this document.
Any worn or damaged gate hardware must be repaired or replaced before installing the gate operator.
Vehicular gates are to be constructed and installed in accordance with the ASTM F2200 contruction
standards.
Electricity
The CM9-2 is powered by 110v-120v AC power. IF you have not already done so, and you are not using
solar power, wire a waterproof outlet near the gate following proper safety standards for your area. we’re
recommended hire a state licensed electrician to perform all your wiring tasks as well as wire in the CM9-2
swing linear arm. Make sure your electrician takes into account the voltage drop involved in running many
feet of wire to your installation location. If an insufficient gauge of wire is used, the gate operator may have
insufficient power.
The gate operator must be disconnected from the power source before the installation. This also includes
gate operator accessories.

CONTROL BOX INSTALLATION
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 06
FIGURE A
FIGURE C
Drill Hole
FIGURE B
Baseboard
Unscrew
To Remove
Option 1 - Mounting with Included Plastic Hinges:
1. On the back of CM9-2, locate the 4 plastic hinges attached with a Philips screw on each corner.
2. Unscrew the Philips screws and turn the plastic hinges to the desired position and angle (FIGURE A).
3. Tighten the Philips screws to secure the plastic hinges in place.
4. Position the power box on the wall where you want to mount it and mark 4 holes.
5. Drill holes and use wall anchors to mount the power box securely.
Option 2 - Mounting Direct:
1. On the back of CM9-2, unscrew the 4 Philips screws and remove the 4 plastic hinges from the corners.
2. Open the power box and remove the 4 Philips screws (FIGURE B) on the baseboard to disconnect the
circuit board system from the control box case.
3. Drill 4 holes from the marked location (FIGURE C) on the back of the control box case, to create a mount
holes.
4. Drill holes and use wall anchors to mount the box securely, and consider using liquid shield to shield the
mounting holes for added protection.
5. Reinstall the circuit board system (baseboard) back into the case and secure it with the 4 Philips screws.

LINEAR ARM INSTALLATION (OPEN INSIDE)
Single Gate Installation Set-up Double Gate Installation Set-up
FIGURE A
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 07
1. Weld the Wall Bracket to the Wall Plate to create a stable base for
the linear arm (FIGURE A).
2. Mounting the Wall Plate to the Wall: first drill holes in the desired
location on the wall, and use wall anchors to securely mount the
Wall Plate to the wall.
3. Use the included nut, washers, and bolt to connect the CM9-2 Linear
Arm to the Wall Plate. Tighten the bolt to secure the Linear Arm to the
Wall Plate (FIGURE B)
4. Position the Gate Plate to be level with the CM9-2 Linear Arm. Once
everything is leveled and measured, weld the Gate Plate to the gate,
and ensure that the plate covers up to 3 pickets on the gate (FIGURE C).
5. Connect the Gate Mount Bracket to the Linear Arm travel bolt. Adjust
the bracket until the measurements match the suggestions on page 8.
6. Weld the Gate Bracket securely to the Gate Plate, and Verify that
everything is stable and secure
Please note that welding should be done by a professional and skilled welder to ensure safety and durability.
Additionally, follow all safety guidelines and use appropriate tools and materials as specified in the product's
manual or instructions.
FIGURE C
WALL
CALIMET -CM9-2
FIGURE B
WALL
GATE
CALIMET -CM9-2

LINEAR ARM INSTALLATION (OPEN INSIDE)
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01 PAGE 08
Refer to the illustrations below to determine the measurement of the swing linear arm operator.
Single Gate Installation Set-up Double Gate Installation Set-up
(°) A
90° 6-3/4”
90° 7-1/4”
110° 6-3/4”
110° 5-1/2”
B
7”
7-1/4”
7”
6”
C
4-4/3”
4-4/3”
4-4/3”
4-4/3”
CALIMET -CM9-2
WALL
GATE
A
B
CALIMET -CM9-2
C
Table of contents