Caen ELS WPOLINV200XA User manual

Polarity Inverters
200 A, 400 A, 600 A
Polarity Inverters
User’s Manual
All Rights Reserved
© CAEN ELS s.r.l.
Rev. 1.2 –November 2022
POLARITY INVERTERS

2
This product is
&
compliant.
CAEN ELS s.r.l.
c/o AREA Science Park
S.S. 14 km 163,5 - 34149 Basovizza (TS)
Italy
Mail: [email protected]
Web: www.caenels.com

3
POLARITY INVERTERS - USER’S MANUAL
This manual covers the following standard models:
WPOLINV200XA
WPOLINV400XA
WPOLINV600XA
For technical assistance please refer to the following contact:
CAEN ELS S.R.L.
SS14 km 163,5
34149 Basovizza (TS) –Italy
(c/o Area Science Park –Building Q1)
Phone: +39 040 375 6610
Fax: +39 040 375 6611
Mail: [email protected]

Polarity Inverters –User’s Manual
4
Table of contents
1. INTRODUCTION................................................................................................9
1.1 POLARITY INVERTER OVERVIEW ....................................................................9
1.2 SYSTEM PARTS .............................................................................................11
WPOLINV200XA .....................................................................................11
WPOLINV400XA / WPOLINV600XA......................................................13
2. INSTALLATION...............................................................................................16
2.1 PREPARATION FOR USE.................................................................................16
2.2 INITIAL INSPECTION ......................................................................................16
2.3 MOUNTING....................................................................................................17
2.4 AC INPUT POWER CONNECTIONS..................................................................17
AC Input Requirements............................................................................17
AC Input Cord..........................................................................................18
2.5 CONNECTIONS...............................................................................................19
Power Connectors....................................................................................21
2.5.1.1 WPOLINV200XA .................................................................................21
2.5.1.2 WPOLINV400XA / WPOLINV600XA..................................................22
Control and Monitoring Connector.........................................................23
Earth connection......................................................................................24
3. TECHNICAL SPECIFICATIONS ..................................................................25
4. MECHANICAL DIMENSIONS.......................................................................26
5. CONTROL CABLE...........................................................................................28
6. NGPS CONFIGURATION...............................................................................29

Polarity Inverters –User’s Manual
5
Document
Revision
Date
Comment
1.0
December 11th, 2017
First Release
1.1
June 26th, 2022
Added 400/600 A models
1.2
November 22nd, 2022
Added UKCA compliance logo

Polarity Inverters –User’s Manual
6
Safety information
The following table shows the general environmental requirements for a correct
operation of referred instruments in this User’s Manual:
Environmental Conditions
Requirements
Environment
Indoor Use
Operating Temperature
0°C to 45°C
Operating Humidity
20% to 80% RH (non-condensing)
Altitude
Up to 2000 m
Pollution degree
2
Overvoltage Category
II
Storage Temperature
-10°C to 60°C
Storage Humidity
5% to 90% RH (non-condensing)
The following symbols are used within this manual or are reported in the box
and along this manual:
•Caution: Documentation must be consulted in all cases where this
symbol is marked
•0 Off (Power)
•I On (Power)
•The WARNING sign denotes a hazard. An attention
to a procedure is called. Not following procedure correctly could result in
personal injury. AWARNING sign should not be skipped and all indicated
conditions must be fully understood and met.
•The CAUTION sign denotes a hazard. An attention to a
procedure is called. Not following procedure correctly could result in
damage to the equipment. Do not proceed beyond a CAUTION sign until all
indicated conditions are fully understood and met.
WARNING
CAUTION

Polarity Inverters –User’s Manual
7
CAEN ELS will repair or replace any product within the guarantee period if the
Guarantor declares that the product is defective due to workmanship or materials and
has not been caused by mishandling, negligence on behalf of the User, accident or any
abnormal conditions or operations.
Please read carefully the manual before operating any part of the instrument
Do NOT open the boxes
CAEN ELS s.r.l. declines all responsibility for damages or injuries caused by an
improper use of the Modules due to negligence on behalf of the User. It is strongly
recommended to read thoroughly this User's Manual before any kind of operation.
CAEN ELS s.r.l. reserves the right to change partially or entirely the contents of this
Manual at any time and without giving any notice.
Disposal of the Product
The product must never be dumped in the Municipal Waste. Please check your local
regulations for disposal of electronics products.
WARNING

Polarity Inverters –User’s Manual
8
•Do not use this product in any manner not specified by
the manufacturer. The protective features of this
product may be impaired if it is used in a manner not
specified in this manual.
•Do not use the device if it is damaged. Before you use
the device, inspect the instrument for possible cracks or
breaks before each use.
•Do not operate the device around explosives gas, vapor
or dust.
•Always use the device with the cables provided.
•Turn off the device before establishing any connection.
•Do not operate the device with the cover removed or
loosened.
•Do not install substitute parts or perform any
unauthorized modification to the product.
•Return the product to the manufacturer for service and
repair to ensure that safety features are maintained
WARNING

Polarity Inverters –User’s Manual
9
1.Introduction
This chapter describes the general characteristics and main features of the
Polarity Inverters WPOLINV200XA, WPOLINV400XA and WPOLINV600XA.
1.1 Polarity Inverter Overview
Extreme reliability and easiness of configuration and maintenance are the key
features of these polarity inverters.
These polarity inverters are able to reverse currents up to 630 A and so they
represent the perfect fit for the CAEN ELS NGPS unipolar power supplies, both in single
or paralleled configurations.
Each polarity inverter fits in a single 19”6U crate and it can be controlled via
dry contacts while providing to the user information about the correct working of the
system and the selected polarity.
Figure 1: Schematic of the unit.
Polarity inversion is achieved with a linear motor acting as commutator, this
avoiding any possible problem even in case of e.g. black out –which represents an
issue if inversion is obtained via relays-based commutators.
Figure 1 represents the schematic operation of the unit. A linear motor is
responsible for the polarity switching, e.g. in Figure 1 the selected polarity is reversed.

Polarity Inverters –User’s Manual
10
These polarity inverters have the following ratings listed in Table 1:
Model
Description
Maximum Voltage
Maximum Current
WPOLINV200XA
200 A Polarity Inverter
250 V
200 A
WPOLINV400XA
420 A Polarity Inverter
250 V
420 A
WPOLINV600XA
630 A Polarity Inverter
250 V
630 A
Table 1: Main ratings of the polarity inverters.
If the rear power connections of the Polarity Inverter are
accessible, IN and OUT connections result in HAZARDOUS
LIVE parts and must be isolated or confined following local
regulations.
If the Maximum Voltage level is below 70 VDC further
isolations are not required.
All these polarity inverters are already supplied with the signal cable that allows
connecting them directly to an NGPS power supply.
WARNING
This manual suits for next models
2
Table of contents