2 Generally
Thank you for deciding for a safe with the BURG-WÄCHTER TRSE 6000
electronics. This electronics is VdS-certified for class B. You have acquired
a product meeting extremely high security requirements and developed
and manufactured using the latest technical potential.
Please read the entire User Manual before programming and store it at a
safe place for future reference.
The TRSE 6000 electronics is available in a TRSE 6000 FP version with a
fingerscan unit and in another version TRSE 6000 without the fingerscan
unit. The present user manual applies to both versions, however, the menu
structure is able to detect automatically the appropriate version and thus
only the menu items intended for it are active. The items relevant only for
the electronics with a fingerscan unit are marked with*.
Generally, you can open the safe in three possible ways:
– with a code
– with an E-Key (ident medium TSE 5103 E-Key SB and TSE 6103 E-Key
not included in the delivery)
– with your fingerprint*
The administrator code when delivered from the factory is 123456. This
code must be changed. Additional 9 users with a code to be entered by
the keyboard can be defined. Such code has always six digits, similarly to
administrator’s code.
Additionally, up to 300 E-Keys for contactless opening can be stored.
In case you posses a safe with a fingerscan unit, up to 10 users with
fingerscan can be additionally stored. Users with fingerscan are identified
in the user list of the lock as USER xxx_FP.
The TRSE 6000 FP electronics is the first safe electronics, for which the
opening based on fingerscan is certified.
At least two opening codes shall be entered to open the safe using
fingerprint. Another opening code must be entered in addition to fingerscan.
This can be either another fingerscan, but also a pin code or an E-Key.
All the fingerscans are stored in the system with a value of ½. In order to
acquire the authorization to open, a value of at least 1 must be achieved.
A pin code with a value of at least ½ must be therefore entered for the
opening, a value of 1 can be also achieved with an additional fingerscan.
Attention: The values can only be adjusted using TSE Light, TSE System and
System + software. When a PIN code user or an E-Key user is being created
for the safe, an inquiry is made on whether the opening code shall be used
together with a fingerprint. Correspondingly, the value is then automatically
set to ½. Otherwise the PIN code and the E-Key are assigned values of 1,
the fingerscan is always assigned a value of ½.
Blocking times: To protect the lock against manipulation the electronics
block the access to the safe for 5 minutes if 3 incorrect pincodes have
been entered one after another. With every following wrong pincode
for 10 minutes. During this period, the display shows the remaining
countdown time. Opening the safe is also not possible with a valid user
or administrator code.
In order to enhance the protection against intrusion,
the following points should be observed:
For locking systems with material code carriers, e.g. an E-Key:
– The code carrier should be consistently stored safely, so that it is accessible
only to the authorized persons.
– In case of a loss of the code carrier, the lock should be immediately
replaced or converted to a new combination by changing the coding,
and/or the code of the lost code carrier should be blocked/deleted.
For locking systems requiring a code:
– No personal data (e.g. dates of birth) or other data, for which a link can
be derived to the code owner, should be used for coding.
– If the code is stored in writing, such document should be consistently
stored safely, so that it is accessible only to the authorized persons.
– Attention: Any changes of the administrator code and of the user codes
shall be made with the safe door opened!
– When the locking system has been reset to another code, this new code
should be repeatedly used with the safe door opened.

TSE BUSINESS 5000 English |8
2.1 Description of basic functions
You can program your lock based on the following description.
You can see the programming instructions on the display. To program the
lock (enter into the menu), please press the “Function” key, when the
symbol “M” is displayed. You can move within the menu using the keys “1”
scroll up (symbol on display) and “2” scroll down (symbol on display). When
the symbol “<” is displayed, you can use the “Function” key to skip to the
next higher menu level, and choose a particular menu item using the “Enter/
On” key. The battery symbol indicates the current battery status:
Battery full
[][][] Battery empty (please replace the batteries)
The batteries are replaced in a way depending on the safe fittings.
Battery replacement page 22
2.2 Description of programming and user mode
Please find the menu structure shown on the following pages. Also the
navigation is indicated. Additionally, each of the menu items is clarified:
Code change menu
Change of the administrator and user codes
Language/ Sprache menu
Language setup
E-Key synchronization menu
In this program, the channel of the E-Key is adapted to the channel of the
input unit.
This function is necessary when the radio channel of an input unit is
modified, although other radio keys (with the old channel setup) are still
logged.
Info menu
– Indication of version and serial number
– SNA: Lock serial number (via type in the Administration code)
Administrator menu
This includes all the menus that can be used only with the administrator
authorizations. They include:
– Create User:
Users can be created here. A user has either a code, or an E-Key, or both.
A separate user is always created for a fingerscan.
Anatomically, there are people, the fingerprints of whom are not
sufficiently articulated for the system.
– Assign E-Key:
An E-Key can be additionally assigned to a selected user here.
– Delete:
Users and E-Keys can be deleted here. When a user is deleted, also the
code and the E-Key belonging to the user are deleted. When an E-Key
is deleted, the user is retained. To delete a fingerscan, the corresponding
user has to be deleted. To delete all the fingerscans, please use the
“FS-Reset” function (see below).*
– Time:
Entry of the time and calibration of the clock. The clock is automatically
calibrated between two specific times. Exceptions are a replacement of
batteries and the switchover from summer to winter time.
– Date:
Entry of date
– Radio Channel:
The radio channel can be set up here (12 channels to select from). This
can be required when the radio channel is already used by another
application, e.g. WLAN. In case of collision with WLAN systems, a space
of three channels is recommended.
– Priority:
In case the door cannot be opened after several attempts with the E-Key,
the priority of the door can be increased by this function. Inversely, also
the priority of other door within the direct environment can be reduced.
– Restructure:
The use of this function is recommended when several users have been
deleted.
– Register:
When either the lock unit or the keyboard is replaced, the two units are
newly tuned to each other.
– FS-Reset*:
All the stored fingerprints are deleted, however, the corresponding users
are retained. Please select this menu and follow the instructions on the
display also in case of repeated error functions related to the use of
fingerscans. These fingers could not be stored because of security reasons.

TSE BUSINESS 5000 English |9
2.3 Menu structure
Menu
Code Change Menu Language Menu
Administrator
Menu
KEY sync.
Selection
Admin. Setup
Create User
E-KeyCode Fingerprint
User.xxx
Code enter
Select FP-com.
with ENTER
Select FS-com.
with ENTER
E-Key in
prog. Mode
Cont. with
ENTER
Store with ON
key!
User.xxx
Teach in E-Key
with ENTER
Teach-in E-Key
with ENTER
Data record
deleted
Key in
prog. Mode
Cont. with
ENTER
User 1
…
User.1999
User 1
…
User 1999
Delet data by
pressing
ON-Taste
Finger
Anlernen
1
-
-
X
Admin.
Code
Admin.
Code
Admin.
Code
Admin.
Code Admin.
Code
Admin.
Code
Admin.
Code
Admin.
Code
Admin.
Code
Admin.
Code
Admin.
Code
Hours
Day
Month
Year
Minutes
Admin.
Code
Admin. Setup
Assign E-Key
Admin. Setup
Time Entry
Admin. Setup
Date Entry
Admin. Setup
Radio Channel
Admin. Setup
Priority
Delete:
User
Delete:
E-Key
Connection:
Channel
Restructuring in
progress
Free space not
available!
Data are stored!
Data are stored! Data are stored! Data are stored! Data are stored!
Data are stored! Wrong Code! Please repeat!
Delete Data
by pressing
ON-Taste
Priority
Admin. Setup
Restructure
Admin. Setup
Install Keyboard
Admin. Setup
FS-Reset
E-Key in prog. Mode
cont. with ENTER
Admin. Setup
Delete
New code
Repeat entry
Code change
completed
Data are
stored!
Data are
stored!
Free space not
available!
Free space not
available!
Free space not
available!
Data are stored! Free space not
available!
Impos-
sible!
Impos-
sible!
Impos-
sible!
UserXXX_FP
created
Teach-in
Finger failed
Impossible!
Impossible!
Previous code
Administrator
User 1
…
User 9
Menu
Info
EE AE
SNA:01.23.45.67
E E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
Menu
Display Input
Administrator
User
E=Enter

TSE BUSINESS 5000 English |10
2.4 Detailed description of selected basic functions
1. Opening the safe using the factory code
– Press the On/Enter key
– The Code/Fingerp indication is displayed (in case you possess electronics
without fingerscan, Code is displayed instead.)
– At this point you are asked to enter the Admin.
Code (factory setting 123456)
– The instruction Please turn knob is displayed
Attention: The message Please turn knob implies the action with the knob
of the locking unit, for which the opening code has been entered.
2. Changing the Administrator Code
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Press the Function key
– The Change code menu is displayed
– Press the On/Enter key
– The indication of Administrator is displayed
– Press the On/Enter key
– The indication of the Old code is displayed
– At this point you are asked to enter the Admin.
Code (factory setting 123456)
– Press the On/Enter key
– The indication of the New code is displayed
– Enter the new code
– Press the On/Enter key
– The indication of Repeat code is displayed
– Enter the new code
– Press the On/Enter key
– The indication of Code successfully changed is displayed
3. Creating a user with a code
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Press the Function key
– The Change code menu is displayed
– By pressing the key 2 reach the Administrator menu
– Press the On/Enter key
– Admin setup Create user is displayed
– Press the On/Enter key
– Create code is displayed
– Press the On/Enter key
– At this point you are asked to enter the Admin.
Code (factory setting 123456)
– The indication of User 00x is displayed
– Please enter the user code and confirm it with ENTER
– Press the On/Enter key
– FS combination to be confirmed with ENTER is displayed1
– Press the On/Enter key and accordingly the Function key
– After confirmation, Save with the On key is displayed.
4. Creating a user with an E-Key
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Press the Function key
– The Change code menu is displayed
– By pressing the key 2reach the Administrator menu
– Press the On/Enter key
– Admin setup Create user is displayed
– Press the On/Enter key
– Create E-Key is displayed
– Press the On/Enter key
– At this point you are asked to enter the admin.
Code (factory setting 123456)
– FS combination to be confirmed with ENTER is displayed1
– Press the On/Enter key and accordingly the Function key
– User 00x Store E-Key using ENTER is displayed
– Please bring the E-Key in the programming mode.
– Press the On/Enter key
– E-Key in Prog mode, continue with Enter is displayed
– Press the On/Enter key
– After confirmation, Save with the On key is displayed
1If the message FS combination to be confirmed with ENTER is
displayed you have to decide whether the user should get the full
opening right or half of it.
Full opening right: press Function key
Half opening right: press ENTER key
If you create a half opening right the Pin code is only to be allowed
to open with another opening secret e.g. the fingerprint.

TSE BUSINESS 5000 English |11
5. Storing a user with fingerprint*
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Press the Function key
– The Change code menu is displayed
– By pressing the key 2reach the Administrator menu
– Press the On/Enter key
– Admin setup Create user is displayed
– Press the On/Enter key
– By pressing the key 2several times reach the Create fingerscan menu
– Press the Function key
– At this point you are asked to enter the admin.
Code (factory setting 123456)
– The indication of Create fingerscan is displayed
– The indication of Store finger is displayed
– Please pull your finger over the sensor for several times according
to the instructions shown on the display
– After a successful entry the indication User xxx successfully created
is displayed
Attention: When saving a fingerprint it is important that the finger is laid
evenly and in a straight position over the sensor. Follow the instructions
on the display. The finger is saved only when it can be read in an optimum
quality.
6. Opening with fingerprint*
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Move the saved finger over the sensor
– Value not achieved is displayed for a short time
– The Code/Fingerp indication is displayed
– At this point, enter an additional opening code.
– The instruction Please turn knob is displayed
7. Deleting a finger*
– Press the On/Enter key
– The indication of Code/Fingerp is displayed
– Press the Function key
– The Change code menu is displayed
– By pressing the key 2reach the Administrator menu
– Press the On/Enter key
– Admin setup Create user is displayed
– By pressing the key 2reach the Admin. setup Delete menu
– Press the On/Enter key
– Delete user is displayed
– Press the On/Enter key
– At this point you are asked to enter the admin.
Code (factory setting 123456)
– Now you have to select the appropriate user by pressing the keys 1or 2
– Press the On/Enter key
– The indication of Delete data to be confirmed with the On key
is displayed.
– Press the On/Enter key
– The indication of Data record deleted is displayed
Additional users can be deleted using the On/Enter key. By pressing the
Function key, you can reach higher menu levels up to the code entry.
2.5 Error messages*
The following error messages are indicated when a finger is being
saved or the safe opened:
Error message Elimination of causes
too fast!
please repeat
Move the finger more slowly over the sensor
too aslant!
please repeat
Move the finger straight over the sensor
too short!
please repeat
Move the finger over the sensor in a way allowing
more surface area to be rea
place to the center
and repeat!
Place your finger centrally over the sensor

TSE BUSINESS 5000 |22
Batterien/Batteries/Batterijen: 2x 1,5V Mignon (LR6)
Codeeingabe/Code entry/Entrée code/Code invoer
5 Batteriewechsel/Replacement of batteries/
Changer la batterie/ Batterijwissel