Briton 2130B.T is a spring adjustable power size EN 2-4 track
arm door closer with adjustable closing speed, latch action and
backcheck.
This combination of engineering quality and good looks creates a
truly versatile architectural solution for any severe of heavy duty
application.
Certification
UKCA Marked to EN 1154 (1121-CPR-UK-AD7579)
CE Marked to EN 1154 (2812-CPR-AD0032)
Certifire Approved (CF111)
Fire tested to EN 1634-1 for use on fire doors up to 2hr timber / 1hr steel [* May be
fitted to fully insulated steel based doorsets or uninsulated steel based doorsets
where the closer is fitted to the fire risk face only].
Environmental Product Declaration in accordance with ISO 14025 & EN 15804
DoP available at www.doorhardware-online.co.uk
Features & Functions
Spring adjustable power size EN 2-4
Slide track application
Certified for door mount pull side
fixing
Adjustable closing speed & latch
action
Built-in adjustable backcheck to
prevent damage to the door and
frame
Unique self-adhesive ‘Accufit’
installation template and mounting
plate with dowel fixings to position
the closer body ensures a quick,
simple and accurate installation
All-over Classic cover conceals
fixings and adjustment screws to
prevent tampering
Suitable for fire door application
2130B.T
2130B.T.SES
*

DOOR CONTROLS
Overhead Closer Briton 2130B.T
nStandard nAvailable as an option/variant
Finishes
All finish variants are supplied with
matching armset and brackets.
Other sprayed finishes are available
on request.
Closer with Classic C cover
All dimensions are in mm
Figures in brackets refer to dimensions when used with hold-open armset
Accessories & Parts
2130.T.AP Track arm pack
2130.T.FP Track arm fixing pack
2130.T.FPS Security fixing pack
Product features Product references
2130B.T
Closer type Track arm
UKCA & CE marked n
Closing power EN size 2 - 4
Adjustment type Spring power
Door limits (width/weight) 1100mm/80kg
Maximum angle of opening 180˚
Adjustable closing speed & latch action n
Adjustable backcheck n
Adjustable delayed action
Slide channel and track arm n
Electromagnetic hold-open facility n
Cover variants C cover
Finishes available SES, SSS, PBS, PSS
CE Classification 4 8 2-4 1 1 3
66
310
55
490
20
66 310
55
578
20
310
55
66
Low Ceiling
Low Ceiling Low Ceiling
7- max.
28 (41)
min.
55
min.
50
min.
28 (42)
min.
68
min.
94 (107)
min.
44
12- max.
41
min.
78
min.
55
min.
45
min.
78
min.
95
min.
76- max.
75
min.
22
min.
Door mount
Pull side
Transom mount
Push side Transom mount
Pull side
SES
Sprayed silver
SSS
Satin
stainless steel
PSS
Polished stainless
steel
PBS
Polished brass

DOOR CONTROLS
Overhead Closers
2130B.T
APPLICATION A - DOOR FIXING - PULL SIDE APPLICATION C - TRANSOM FIXING - PULL SIDE
R. H. door
R. H. door
POWER SIZE 2 - 4 POWER SIZE 2 - 4
L. H. door
APPLICATION B - TRANSOM FIXING - PUSH SIDE
POWER SIZE 2 - 4
L. H. door R. H. door L. H. door
64
473
191
112
25
15
45
64
C/LINE
OF HINGE
191
473
112
15
25
45
25
25
64
64
C/LINE
OF HINGE
15
82 45
191
473
15
45 82
473
191
69 473
191
108
25 10
45
108
69
C/LINE
OF HINGE
25
45
10
191
473
Installation dimensions
Door Mount
Door mounted pull side for power
sizes EN 2 - 4
Transom Mount
Transom mounted push side for power
sizes EN 2 - 4
Transom Mount
Transom mounted push side for power
sizes EN 2 - 4
APPLICATION A - DOOR FIXING - PULL SIDE APPLICATION C - TRANSOM FIXING - PULL SIDE
R. H. door
R. H. door
POWER SIZE 2 - 4 POWER SIZE 2 - 4
L. H. door
APPLICATION B - TRANSOM FIXING - PUSH SIDE
POWER SIZE 2 - 4
L. H. door
R. H. door L. H. door
64 473
191
112
25
15
45
64
C/LINE
OF HINGE
191
473
112
15
25
45
25
25
64
64
C/LINE
OF HINGE
15
82 45
191
473
15
45 82
473
191
69 473
191
108
25 10
45
108
69
C/LINE
OF HINGE
25
45
10
191
473
APPLICATION A - DOOR FIXING - PULL SIDE APPLICATION C - TRANSOM FIXING - PULL SIDE
R. H. door R. H. door
POWER SIZE 2 - 4 POWER SIZE 2 - 4
L. H. door
APPLICATION B - TRANSOM FIXING - PUSH SIDE
POWER SIZE 2 - 4
L. H. door
R. H. door L. H. door
64 473
191
112
25
15
45
64
C/LINE
OF HINGE
191
473
112
15
25
45
25
25
64
64
C/LINE
OF HINGE
15
82 45
191
473
15
45 82
473
191
69 473
191
108
25 10
45
108
69
C/LINE
OF HINGE
25
45
10
191
473

DOOR CONTROLS
2130B.T
General Maintenance
Door controls
In research, Allegion has identified
that 95% of all problems associated
with overhead door closers can
be attributed directly to errors in
installation rather than problems with
the door closer itself. If the door is not
closing properly into the frame you
should first disconnect the door closer
(disconnect the arm(s)) and determine
that there is not an underlying problem
with the door, frame or any smoke /
draft seals that might be fitted.
PLEASE NOTE:
The power of the door closer should
not be used to overcome problems
associated with the door or other
items of hardware fitted to it.
Under no circumstances should the
closer body be dismantled.
Types of maintenance
Much of the routine maintenance recommended consists of a combination of
visual and mechanical checks, cleaning and lubrication. Look out for the icons
opposite which provide a ‘quick glance’ reminder of the maintenance required.
Visual checks
Primarily making a visual check on the product and surrounding
door/frame looking for wear, damage, and general condition.
Functional checks
Consists of checking that the product operates properly ensuring
the door can fully close without any binding or undue force
required. Check that any seals or weatherstripping do not inhibit
correct operation of the door
Check fixings
Fixings need to be checked regularly and tightened when
necessary. Check that no projection of fixings prevents the door
from swinging freely.
Lubricating
Some products will benefit from periodic lubrication using a light
machine oil or as instructed.
Cleaning
Build up of grease, dust and harmful chemicals should be removed
to prevent corrosion and maintain the product finish.

DOOR CONTROLS
Closer Maintenance
WEEKLY
Release the door from the fully open position and ensure that it closes fully into
the frame. Ensure the latch (if fitted) engages fully into the strike plate. Repeat the
process a few times from dierent angles of opening to ensure the door closes
consistently each time.
Check and adjust the closing and latching speeds if necessary.
Check the backcheck comes into operation at the desired angle and readjust if
necessary.
Check that the door or hardware does not come into contact with the door frame
or the surrounding structure.
QUARTERLY
The fixings of the closer body and the slide track are subject to stress and should
be checked carefully to make sure they are tight.
Periodically apply a little light machine oil to the moving joints of the arm and slide
track.
Check any fire and smoke seals to ensure they do not foul the action of the door.
Check for any loss of fluid from the door closer body which would indicate a
failing device.
Clean the closer body, arms and track if necessary following the guidance on
“Care of Finishes” on page 16 of the ‘Service & Maintenance Guide’.
FIRE DOOR APPLICATIONS
When installed as part of a fire precaution system the door closing mechanism,
including the door selector if used on a double door arrangement, should be
checked in accordance with standing periodic fire testing procedures.
Routinely check that all fixings of the closer body and track are tight.
Routine care of finishes as necessary.
Table of contents
Other Briton Door Opening System manuals
Popular Door Opening System manuals by other brands

Normstahl
Normstahl IDO7 installation manual

Häfele
Häfele Finetta T 70 VF manual

AGS
AGS D-PL Instructions for fitting, operating and maintenance

Stanley
Stanley MA900ñ Installation and owner's manual

WITTUR
WITTUR Hydra Plus UD300 Instruction handbook

Alutech
Alutech TR-3019-230E-ICU Assembly and operation manual